CVE-2010-4597

highpriority · attend · 57EPSS 0.188 · 97 %ileexploit · functionalEUUS
grimoire priorityP1 · Urgent
Exploitable?
Public exploit
1 exploit · functional
Likely / severe?
18.8% (97th) EPSS
CVSS 10 · high
Is it mine?
12 products
Check your exposure
Who says so?
3 sources
enisa_euvd · cisa_csaf_ot · nvd

EPSS · scored 2026-10-27

Stack-based buffer overflow in the save method in the IntegraXor.Project ActiveX control in igcomm.dll in Ecava IntegraXor Human-Machine Interface (HMI) before 3.5.3900.10 allows remote attackers to execute arbitrary code via a long string in the second argument.

01

remediations

Vendor fix, mitigation, or workaround guidance, as published by each source.

No vendor fix yet; a mitigation is available.

  • MitigationEasy Connect (EC150)cisa_csaf_ot

    Minimize network exposure for all control system devices. Critical devices should not directly facethe Internet. Control system networks and remote devices should be located behind firewalls, and beisolated from the business network. If remote access is required, secure methods such as virtual private networks (VPNs) should be utilized.

  • MitigationModbus RTU – TCP Gateway (MB100)cisa_csaf_ot

    Minimize network exposure for all control system devices. Critical devices should not directly facethe Internet. Control system networks and remote devices should be located behind firewalls, and beisolated from the business network. If remote access is required, secure methods such as virtual private networks (VPNs) should be utilized.

  • MitigationSerial Ethernet Server (SS100)cisa_csaf_ot

    Minimize network exposure for all control system devices. Critical devices should not directly facethe Internet. Control system networks and remote devices should be located behind firewalls, and beisolated from the business network. If remote access is required, secure methods such as virtual private networks (VPNs) should be utilized.

  • MitigationWebSCADA (WS100)cisa_csaf_ot

    Minimize network exposure for all control system devices. Critical devices should not directly facethe Internet. Control system networks and remote devices should be located behind firewalls, and beisolated from the business network. If remote access is required, secure methods such as virtual private networks (VPNs) should be utilized.

  • MitigationWebSCADA (WS200)cisa_csaf_ot

    Minimize network exposure for all control system devices. Critical devices should not directly facethe Internet. Control system networks and remote devices should be located behind firewalls, and beisolated from the business network. If remote access is required, secure methods such as virtual private networks (VPNs) should be utilized.

02

cvss

Technical severity, 0–10. One row per scoring source.

10.0
010

base score 0–10 · higher = more severe · hover a vector to decode⚠ sources disagree · high–critical · 9–10

v2.010highAV:N/AC:L/Au:N/C:C/I:C/A:Cprimary · NVD / NIST USexploitability 10 · impact 10
v2.010criticalAV:N/AC:L/Au:N/C:C/I:C/A:Csecondary · CISA US
v2.09highAV:N/AC:L/Au:N/C:C/I:C/A:C/E:POCsecondary · CVSS-BT (t0sche)
03

weaknesses

The CWE weakness classes this flaw belongs to.

04

exploits (1)

Public proof-of-concept and weaponised exploit code.

05

affected products (12)

Products and version ranges known to be affected.

06

advisories (1)

Vendor and ecosystem advisories describing this.

  • ICSA-10-322-01Ecava IntegraXor Buffer Overflow2010-08-21icsa · cisa_csaf_otUS

    This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov

07

also known as (2)

Other names and identifiers for this entity.

08

sources

Which sources assert this record, and when.

published 2010-12-23modified 2026-06-16
10

references (14)

External citations — patches, advisories, analysis.

scry

Attackers weaponise vulnerabilities like this against internet-exposed services. See what is exposed on your perimeter with a free passive scan.

Free scan