Bender PSIRT (CSAF)

advisoryDE

bender_psirt

Bender PSIRT CSAF 2.0 advisories (hosted by CERT@VDE).

01

advisories (5)

Vendor and ecosystem advisories describing this.

02

product assertions (29)

Products and version ranges known to be affected.

03

CVE links (11)

Known CVEs related to this entry.

IDseverity exploitable
CVE-2026-94410USmedium4.3OT elevated—
A low privileged remote attacker is able to view a list of roles that should only be accessible to administrators. This results in a low level of confidentiality breach, as no part…
CVE-2025-41708US—OT elevated—
Due to an unsecure default configuration HTTP is used instead of HTTPS for the web interface. An unauthenticated attacker on the same network could exploit this to learn sensitive…
CVE-2025-41682US——
An authenticated, low-privileged attacker can obtain credentials stored on the charge controller including the manufacturer password.
CVE-2021-34602UShigh8.8—
In Bender/ebee Charge Controllers in multiple versions are prone to Command injection via Web interface. An authenticated attacker could enter shell commands into some input fields…
CVE-2021-34601UScritical9.8OT elevated—
In Bender/ebee Charge Controllers in multiple versions are prone to Hardcoded Credentials. Bender charge controller CC612 in version 5.20.1 and below is prone to hardcoded ssh cred…
CVE-2021-34591UShigh7.8—
In Bender/ebee Charge Controllers in multiple versions are prone to Local privilege Escalation. An authenticated attacker could get root access via the suid applications socat, ip…
CVE-2021-34590USmedium5.4—
In Bender/ebee Charge Controllers in multiple versions are prone to Cross-site Scripting. An authenticated attacker could write HTML Code into configuration values. These values ar…
CVE-2021-34589UShigh7.5—
In Bender/ebee Charge Controllers in multiple versions are prone to an RFID leak. The RFID of the last charge event can be read without authentication via the web interface.
CVE-2021-34588UShigh8.6—
In Bender/ebee Charge Controllers in multiple versions are prone to unprotected data export. Backup export is protected via a random key. The key is set at user login. It is empty…
CVE-2021-34587USmedium5.3—
In Bender/ebee Charge Controllers in multiple versions a long URL could lead to webserver crash. The URL is used as input of an sprintf to a stack variable.
CVE-2019-19885UScritical9.1OT elevated—
In Bender COMTRAXX, user authorization is validated for most, but not all, routes in the system. A user with knowledge about the routes can read and write configuration data withou…