CVE-2026-54429

highPriorität · verfolgen · 0EPSS 0.003 · 18. PerzentilDEEUNLRUUS
grimoire priorityP2 · Scheduled
Exploitable?
—
no known exploitation
Likely / severe?
0.27% (18th) EPSS
CVSS 7.4 · high
Is it mine?
169 products
Prüfe deine Angriffsfläche
Who says so?
7 sources
cnnvd · enisa_euvd · fstec_bdu · cert_bund

EPSS · bewertet 2026-10-27

A vulnerability has been identified in SIMATIC S7-PLCSIM Advanced (All versions). Affected devices do not properly handle high-volume multicast network traffic, which can exhaust available memory resources in the affected application. This could allow an unauthenticated attacker on the local network segment to cause a denial-of-service condition of the affected application. The affected application becomes inaccessible and requires a manual restart; no project data is lost. Successful exploitation requires a specific project configuration to be already active on the targeted instance.

01

Behebungen

Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.

Noch kein Hersteller-Fix; eine Mitigation ist verfügbar.

  • MitigationSIMATIC S7-PLCSIM Advancedsiemens_psirt

    Disable the S7-PLCSIM Virtual Switch binding on the network adapter used by the affected instance. This prevents the adapter from entering an external communication mode and removes the attack vector entirely. (see SIMATIC S7-PLCSIM Advanced Function Manual V8.0, 11/2025 Section 5.3 and Section 6.1.2.3; and SIMATIC S7-PLCSIM Advanced Function Manual API V8.0, 11/2025 Section 7.2)

  • MitigationSIMATIC S7-PLCSIM Advancedcisa_csaf_ot

    Disable the S7-PLCSIM Virtual Switch binding on the network adapter used by the affected instance. This prevents the adapter from entering an external communication mode and removes the attack vector entirely. (see SIMATIC S7-PLCSIM Advanced Function Manual V8.0, 11/2025 Section 5.3 and Section 6.1.2.3; and SIMATIC S7-PLCSIM Advanced Function Manual API V8.0, 11/2025 Section 7.2)

  • Kein Fix verfügbarSIMATIC S7-PLCSIM Advancedsiemens_psirt

    Currently no fix is available

  • Kein Fix verfügbarSIMATIC S7-PLCSIM Advancedcisa_csaf_ot

    Currently no fix is available

02

cvss

Technischer Schweregrad, 0–10. Eine Zeile je Quelle.

7.4
010

Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen⚠ Quellen uneinig · low–high · 2.3–7.4

v3.17.4highCVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:Hsecondary · NCSC-NL NL
v3.17.4highAV:A/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:Hsecondary · FSTEC (BDU) RU
v3.17.4highCVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:Hsecondary · productcert@siemens.com DEAusnutzbarkeit 2.8 · Auswirkung 4
v3.17.4highCVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:Hsecondary · Siemens ProductCERT DE
v3.17.4highCVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:Hsecondary · CISA US
v4.06mediumCVSS:4.0/AV:A/AC:L/AT:P/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:Lsecondary · ENISA EU
v4.06mediumCVSS:4.0/AV:A/AC:L/AT:P/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:L/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:Xsecondary · productcert@siemens.com DE
v4.02.3lowCVSS:4.0/AV:A/AC:L/AT:P/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:L/E:U/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:Xsecondary · CVSS-BT (t0sche)
03

SSVC

Eine Handlungsentscheidung — aus Ausnutzung und Auswirkung.

Trackcoordinatorcisa_ssvcUS
04

schwächen

Die CWE-Schwächeklassen, zu denen dies gehört.

05

betroffene Produkte (169)

Betroffene Produkte und Versionsbereiche.

06

Advisories (4)

Hersteller- und Ökosystem-Meldungen dazu.

  • NCSC-2026-0229Kwetsbaarheden verholpen in Siemens productenNL2026-07-14csaf · ncsc_nlNL

    Siemens heeft kwetsbaarheden verholpen in diverse producten als CADRA, IAM, Mendix, OpCenter, RUGGEDCOM, SIDIS en SIMATIC.

  • SSA-828211SSA-828211: Denial of Service Vulnerability in SIMATIC S7-PLCSIM Advanced2026-07-14csaf · siemens_psirtDE

    SIMATIC S7-PLCSIM Advanced contains a vulnerability that could allow an attacker to cause a denial of service condition. Siemens is preparing fix versions and recommends specific countermeasures for products where fixes are not, or not yet available.

  • WID-SEC-W-2026-2307Siemens SIMATIC S7: Schwachstelle ermöglicht Denial of ServiceDeutsch2026-07-13csaf · cert_bundDE

    Ein Angreifer aus einem angrenzenden Netzwerk kann eine Schwachstelle in Siemens SIMATIC S7 ausnutzen, um einen Denial of Service Angriff durchzuführen.

  • ICSA-26-209-03Siemens SIMATIC S7-PLCSIM Advanced2026-07-14icsa · cisa_csaf_otUS

    SIMATIC S7-PLCSIM Advanced contains a vulnerability that could allow an attacker to cause a denial of service condition. Siemens is preparing fix versions and recommends specific countermeasures for products where fixes are not, or not yet available.

07

auch bekannt als (5)

Weitere Namen und Kennungen dieser Entität.

08

quellen

Welche Quellen diesen Datensatz belegen und wann.

09

Referenzen (3)

Externe Belege — Patches, Meldungen, Analysen.

scry

Angreifer nutzen Schwachstellen wie diese gegen im Internet exponierte Dienste aus. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.

Kostenloser Scan