CVE-2026-47077

highPriorität · verfolgen · 30EPSS 0.007 · 53. PerzentilEUUS
grimoire priorityP2 · Scheduled
Exploitable?
—
no known exploitation
Likely / severe?
0.70% (53rd) EPSS
CVSS 7.5 · high
Is it mine?
4 products
Prüfe deine Angriffsfläche
Who says so?
4 sources
cnnvd · enisa_euvd · osv · nvd

EPSS · bewertet 2026-10-27

Allocation of Resources Without Limits or Throttling vulnerability in benoitc hackney allows Flooding. hackney_h3:await_response_loop/6 accumulates the HTTP/3 response body in memory without any size cap. The after Timeout clause is a per-message inactivity timer that resets on every received chunk, housekeeping message, or settings frame — it is not a wall-clock deadline. A malicious HTTP/3 server that emits one small chunk every Timeout - 1 ms with Fin = false and never sends a final frame keeps the loop alive indefinitely while the accumulation buffer grows linearly without bound, eventually exhausting the BEAM process heap and causing an out-of-memory condition. This issue affects hackney: from 2.0.0 before 4.0.1.

01

cvss

Technischer Schweregrad, 0–10. Eine Zeile je Quelle.

8.2
010

Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen⚠ Quellen uneinig · medium–high · 4.6–8.2

v3.17.5highCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:Hprimary · NVD / NIST USAusnutzbarkeit 3.9 · Auswirkung 3.6
v3.17.5highCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:Hsecondary · OSV
v4.08.2highCVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:Nsecondary · ENISA EU
v4.08.2highCVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:Xsecondary
v4.04.6mediumCVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:U/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:Xsecondary · CVSS-BT (t0sche)
02

SSVC

Eine Handlungsentscheidung — aus Ausnutzung und Auswirkung.

Exploitation: poc · Automatable: yes · Technical Impact: partialcoordinatorcisa_ssvcUS
03

schwächen

Die CWE-Schwächeklassen, zu denen dies gehört.

04

betroffene Produkte (4)

Betroffene Produkte und Versionsbereiche.

05

Advisories (3)

Hersteller- und Ökosystem-Meldungen dazu.

  • GHSA-76v6-f83q-pxvhDuplicate Advisory: Hackney has an Allocation of Resources Without Limits or Throttling vulnerabilit2026-05-26ghsa · osvUS

    ## Duplicate Advisory This advisory has been withdrawn because it is a duplicate of GHSA-jq4m-q6p2-8gwc. This link is maintained to preserve external references. ## Original Description Allocation of Resources Without Limits or Throttling vulnerability in benoitc hackney allows Flooding. hackney_h3:await_response_loop/6 accumulates the HTTP/3 response body in memory without any size cap. The after Timeout clause is a per-message inactivity timer that resets on every received chunk, housekeeping message, or settings frame — it is not a wall-clock deadline. A malicious HTTP/3 server that emits one small chunk every Timeout - 1 ms with Fin = false and never sends a final frame keeps the loop alive indefinitely while the accumulation buffer grows linearly without bound, eventually exhausting the BEAM process heap and causing an out-of-memory condition. This issue affects hackney: from 2.0.0 before 4.0.1.

  • GHSA-jq4m-q6p2-8gwcHackney: Per-chunk timeout with unbounded body accumulation enables slow-drip OOM2026-06-26ghsa · osvUS

    ### Summary `hackney_h3:await_response_loop/6` in `src/hackney_h3.erl` accumulates the HTTP/3 response body in memory without any size cap. The `after Timeout` clause is a per-message inactivity timer, not a wall-clock deadline: every received `stream_data` chunk, housekeeping `select` message, or `settings` frame resets it. A malicious HTTP/3 server that drips one small chunk every `Timeout - 1` ms with `Fin = false` and never terminates the stream keeps the loop alive indefinitely while the accumulation buffer grows without bound, eventually exhausting the BEAM process heap. ### Details In `src/hackney_h3.erl`, `await_response_loop/6` (line 430) builds the body with: ```erlang NewBody = <<AccBody/binary, Data/binary>> ``` There is no `max_body` check and no monotonic deadline. The `after Timeout` clause at line 463 is restarted on each loop iteration. A server that ensures at least one message arrives within `Timeout` ms indefinitely (one small chunk per interval is sufficient) prevents the timeout from firing while `AccBody` grows linearly. The same module's `wait_connected/3` (lines 388-389) shows the correct pattern: track an absolute start time and pass a shrinking `Remaining` budget into each `receive`. This loop does not. ### Configurations Only the HTTP/3 transport is affected. Applications using the default TCP/TLS hackney transport are not vulnerable. The vulnerability requires using `hackney_h3` directly or passing `{transport, h3}` to `hackney:request/5`. ### PoC 1. Stand up an HTTP/3 server that responds with `200 OK` headers (`Fin = false`), then emits a small `stream_data` chunk every `Timeout - margin` ms with `Fin = false` indefinitely. 2. Issue `hackney:request(get, Url, [], <<>>, [{transport, h3}])` against it. 3. Watch the client process heap grow monotonically. The configured timeout never fires; the process is eventually killed by `max_heap_size` or the OS OOM killer. ### Impact Remote denial of service via unbounded memory consumption. Affects hackney 2.0.0 through 4.0.0 when using the HTTP/3 transport against an attacker-controlled or attacker-influenced server. Each affected request consumes unbounded memory until the BEAM is killed. CVSS v4.0: **8.2 (HIGH)**. ## Resources * Introduction commit: https://github.com/benoitc/hackney/commit/0334af206d5099fdf510ed9eda18e34396f065ad * Patch commit: https://github.com/benoitc/hackney/commit/3d25f9fea26c90609de9d64366fedfe5065413bc

  • EEF-CVE-2026-47077Unbounded body accumulation in HTTP/3 response loop in hackney2026-05-25vendor · osvUS

    ## Summary Allocation of Resources Without Limits or Throttling vulnerability in benoitc hackney allows Flooding. hackney\_h3:await\_response\_loop/6 accumulates the HTTP/3 response body in memory without any size cap. The after Timeout clause is a per-message inactivity timer that resets on every received chunk, housekeeping message, or settings frame — it is not a wall-clock deadline. A malicious HTTP/3 server that emits one small chunk every Timeout - 1 ms with Fin = false and never sends a final frame keeps the loop alive indefinitely while the accumulation buffer grows linearly without bound, eventually exhausting the BEAM process heap and causing an out-of-memory condition. This issue affects hackney: from 2.0.0 before 4.0.1. ## Configurations The application must use the HTTP/3 transport by calling hackney\_h3 directly or by passing {transport, h3} to hackney:request/5. The default hackney transport (TCP/TLS) is not affected.

06

auch bekannt als (8)

Weitere Namen und Kennungen dieser Entität.

07

quellen

Welche Quellen diesen Datensatz belegen und wann.

veröffentlicht 2026-05-25geändert 2026-07-24
08

Referenzen (14)

Externe Belege — Patches, Meldungen, Analysen.

scry

Angreifer nutzen Schwachstellen wie diese gegen im Internet exponierte Dienste aus. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.

Kostenloser Scan