CVE-2026-46747
mediumPriorität · verfolgen · 21EPSS 0.002 · 15. PerzentilDEEUNLRUUSEPSS · bewertet 2026-10-26
A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 6). The affected application does not properly sanitize path input in the `GET /api/sftp/uploadFiles` endpoint used for directory listing. This allows path traversal through crafted input, enabling access to unintended file system locations.
Behebungen
Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.
Ein Hersteller-Fix ist verfügbar.
- BehobenSINEC INSsiemens_psirt
Update to V1.0 SP2 Update 6 or later version
https://support.industry.siemens.com/cs/ww/en/view/110002283/ - BehobenSINEC INScisa_csaf_ot
Update to V1.0 SP2 Update 6 or later version
https://support.industry.siemens.com/cs/ww/en/view/110002283/
cvss
Technischer Schweregrad, 0–10. Eine Zeile je Quelle.
Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen⚠ Quellen uneinig · low–medium · 1.3–5.3
SSVC
Eine Handlungsentscheidung — aus Ausnutzung und Auswirkung.
schwächen
Die CWE-Schwächeklassen, zu denen dies gehört.
betroffene Produkte (281)
Betroffene Produkte und Versionsbereiche.
Advisories (3)
Hersteller- und Ökosystem-Meldungen dazu.
- NCSC-2026-0187Kwetsbaarheden verholpen in Siemens productenNL2026-06-09csaf · ncsc_nlNL
Siemens heeft kwetsbaarheden verholpen in diverse producten als SCALANCE, SIMATIC, SINAMICS, SIPROTEC en TIA Portal.
- SSA-860189SSA-860189: Multiple Vulnerabilities in SINEC INS Before V1.0 SP2 Update 62026-06-09csaf · siemens_psirtDE
SINEC INS before V1.0 SP2 Update 6 is affected by multiple vulnerabilities. Siemens has released a new version for SINEC INS and recommends to update to the latest version.
- ICSA-26-174-04Siemens SINEC INS2026-06-09icsa · cisa_csaf_otUS
SINEC INS before V1.0 SP2 Update 6 is affected by multiple vulnerabilities. Siemens has released a new version for SINEC INS and recommends to update to the latest version.
auch bekannt als (4)
Weitere Namen und Kennungen dieser Entität.
quellen
Welche Quellen diesen Datensatz belegen und wann.
Referenzen (5)
Externe Belege — Patches, Meldungen, Analysen.
- https://access.redhat.com/security/cve/cve-2026-46747cnnvd
- https://cert-portal.siemens.com/productcert/html/ssa-860189.htmlPatchcnnvd
- https://nvd.nist.gov/vuln/detail/CVE-2026-46747cnnvd
- https://cert-portal.siemens.com/productcert/html/ssa-860189.htmlenisa_euvd
- https://cert-portal.siemens.com/productcert/html/ssa-860189.htmlVendor Advisorynvd
Angreifer nutzen Schwachstellen wie diese gegen im Internet exponierte Dienste aus. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.