CVE-2026-31985

highPriorität · verfolgen · 0EPSS 0.002 · 10. PerzentilEUUS
grimoire priorityP2 · Scheduled
Exploitable?
—
no known exploitation
Likely / severe?
0.20% (10th) EPSS
CVSS 8.1 · high
Is it mine?
3 products
Prüfe deine Angriffsfläche
Who says so?
3 sources
cnnvd · enisa_euvd · nozomi_psirt

EPSS · bewertet 2026-10-22

When the upstream Guardian or CMC was configured in the Remote Collector via n2os-tui, the generated configuration disabled TLS certificate verification, and no option was provided to enable it. A malicious actor could perform a man-in-the-middle attack and intercept the communication between the Remote Collector and the Guardian or CMC. This could result in theft of the sync token, impersonation of the server, injection of spoofed data (such as false asset information or vulnerabilities) into the Guardian or CMC, or disruption of the data flow between the Remote Collector and the Guardian or CMC.

01

Behebungen

Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.

Ein Hersteller-Fix ist verfügbar.

  • BehobenRemote Collectornozomi_psirt

    Upgrade Remote Collector to v26.2.0 or later.

  • MitigationRemote Collectornozomi_psirt

    Manually edit the "n2os.conf.user" file in the Remote Collector and remove the "!" prefix from the upstream Guardian or CMC endpoint entry to enable TLS certificate verification.

02

cvss

Technischer Schweregrad, 0–10. Eine Zeile je Quelle.

8.3
010

Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen⚠ Quellen uneinig · medium–high · 4.9–8.3

v3.18.1highCVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:L/I:H/A:Lsecondary · prodsec@nozominetworks.comAusnutzbarkeit 2.2 · Auswirkung 5.3
v3.18.1highCVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:L/I:H/A:Lsecondary · Nozomi Networks PSIRT
v4.08.3highCVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:L/VI:H/VA:L/SC:L/SI:L/SA:Nsecondary · ENISA EU
v4.08.3highCVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:L/VI:H/VA:L/SC:L/SI:L/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:Xsecondary · prodsec@nozominetworks.com
v4.04.9mediumCVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:L/VI:H/VA:L/SC:L/SI:L/SA:N/E:U/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:Xsecondary · CVSS-BT (t0sche)
03

SSVC

Eine Handlungsentscheidung — aus Ausnutzung und Auswirkung.

Trackcoordinatorcisa_ssvcUS
04

schwächen

Die CWE-Schwächeklassen, zu denen dies gehört.

05

betroffene Produkte (3)

Betroffene Produkte und Versionsbereiche.

06

Advisories (1)

Hersteller- und Ökosystem-Meldungen dazu.

  • NN-2026:12-01Disabled and non-configurable TLS certificate validation in n2os-tui when connecting the Remote Collector to a Guardian or CMC, in Remote Collector before v26.2.02026-07-07csaf · nozomi_psirtUS
07

auch bekannt als (3)

Weitere Namen und Kennungen dieser Entität.

08

quellen

Welche Quellen diesen Datensatz belegen und wann.

veröffentlicht 2026-07-09geändert 2026-07-09
09

Referenzen (4)

Externe Belege — Patches, Meldungen, Analysen.

scry

Angreifer nutzen Schwachstellen wie diese gegen im Internet exponierte Dienste aus. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.

Kostenloser Scan