Issue summary: Converting an excessively large OCTET STRING value to a hexadecimal string leads to a heap buffer overflow on 32 bit platforms. Impact summary: A heap buffer overflow may lead to a crash or possibly an attacker controlled code execution or other undefined behavior. If an attacker can supply a crafted X.509 certificate with an excessively large OCTET STRING value in extensions such as the Subject Key Identifier (SKID) or Authority Key Identifier (AKID) which are being converted to hex, the size of the buffer needed for the result is calculated as multiplication of the input length by 3. On 32 bit platforms, this multiplication may overflow resulting in the allocation of a smaller buffer and a heap buffer overflow. Applications and services that print or log contents of untrusted X.509 certificates are vulnerable to this issue. As the certificates would have to have sizes of over 1 Gigabyte, printing or logging such certificates is a fairly unlikely operation and only 32 bit platforms are affected, this issue was assigned Low severity. The FIPS modules in 3.6, 3.5, 3.4, 3.3 and 3.0 are not affected by this issue, as the affected code is outside the OpenSSL FIPS module boundary.

01

Behebungen

Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.

Ein Hersteller-Fix ist verfügbar.

02

cvss

Technischer Schweregrad, 0–10. Eine Zeile je Quelle.

9.8
010

Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen⚠ Quellen uneinig · medium–critical · 5.8–9.8

v3.19.8criticalCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:Hprimary · NVD / NIST USAusnutzbarkeit 3.9 · Auswirkung 5.9
v3.17highCVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:Hsecondary · CISA US
v3.19.8criticalAV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:Hsecondary · FSTEC (BDU) RU
v3.15.8mediumCVSS:3.1/AV:L/AC:H/PR:N/UI:R/S:U/C:L/I:L/A:Hsecondary · ENISA EU
v3.15.8mediumCVSS:3.1/AV:L/AC:H/PR:N/UI:R/S:U/C:L/I:L/A:HsecondaryAusnutzbarkeit 1 · Auswirkung 4.7
v3.17highCVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:Hsecondary · Siemens ProductCERT DE
v3.19criticalCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:Usecondary · CVSS-BT (t0sche)
v3.19.8criticalCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:Hsecondary · NCSC-NL NL
03

SSVC

Eine Handlungsentscheidung — aus Ausnutzung und Auswirkung.

Exploitation: none · Automatable: no · Technical Impact: totalcoordinatorcisa_ssvcUS
04

schwächen

Die CWE-Schwächeklassen, zu denen dies gehört.

05

betroffene Produkte (93)

Betroffene Produkte und Versionsbereiche.

20 von 93 angezeigt
06

Advisories (4)

Hersteller- und Ökosystem-Meldungen dazu.

  • NCSC-2026-0147Kwetsbaarheden verholpen in Siemens-productenNL2026-05-13csaf · ncsc_nlNL

    Siemens heeft kwetsbaarheden verholpen in verschillende (OT-)producten. Het gaat onder andere om producten in de Siemens RUGGEDCOM-, SCALANCE-, SIMATIC-, SIMIT-, SINAMICS-, SIPROTEC-, SENTRON- en Solid Edge-productreeksen.

  • SSA-032379SSA-032379: Multiple Vulnerabilities in SIMATIC CN 4100 Before V5.02026-05-12csaf · siemens_psirtDE

    SIMATIC CN 4100 contains multiple vulnerabilities which could potentially lead to a compromise in availability, integrity and confidentiality. Siemens has released a new version for SIMATIC CN 4100 and recommends to update to the latest version.

  • WID-SEC-W-2026-0995OpenSSL: Mehrere SchwachstellenDeutsch2026-04-07csaf · cert_bundDE

    Ein Angreifer kann mehrere Schwachstellen in OpenSSL ausnutzen, um einen Denial of Service Angriff durchzuführen, vertrauliche Informationen offenzulegen oder andere, nicht näher spezifizierte Angriffe durchzuführen.

  • ICSA-26-134-10Siemens SIMATIC2026-05-12icsa · cisa_csaf_otUS

    SIMATIC CN 4100 contains multiple vulnerabilities which could potentially lead to a compromise in availability, integrity and confidentiality. Siemens has released a new version for SIMATIC CN 4100 and recommends to update to the latest version.