CVE-2026-15688

highPriorität · verfolgen · 0EPSS 0.002 · 7. PerzentilUS
grimoire priorityP2 · Scheduled
Exploitable?
—
no known exploitation
Likely / severe?
0.18% (7th) EPSS
CVSS 8.8 · high
Is it mine?
4 products
Prüfe deine Angriffsfläche
Who says so?
1 sources
cisa_csaf_ot

EPSS · bewertet 2026-10-29

Incorrect Implementation of Authentication Algorithm Vulnerability in Mitsubishi Electric GX Works3 and Motion Control Setting allows a local attacker to successfully authenticate even with an invalid block password by executing the affected product and modifying part of the executable module in memory, and thereby may be able to view, tamper with, destroy, or delete control programs.

01

Behebungen

Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.

Noch kein Hersteller-Fix; eine Mitigation ist verfügbar.

  • MitigationMitsubishi Electric GX Works3cisa_csaf_ot

    For customers of the affected products, Mitsubishi Electric recommends installing antivirus software on a computer running the affected product, to minimize the risk of exploiting this vulnerability.

  • MitigationMitsubishi Electric Motion Control Settings (Software packaged with GX Works3)cisa_csaf_ot

    For customers of the affected products, Mitsubishi Electric recommends installing antivirus software on a computer running the affected product, to minimize the risk of exploiting this vulnerability.

  • WorkaroundMitsubishi Electric GX Works3cisa_csaf_ot

    For customers using GX Works3, please download version 1.096A or later from the link https://www.mitsubishielectric.com/fa/download/software/detailsearch.page?mode=software&kisyu=/plceng&shiryoid=1000001411&lang=2&select=0&softid=1&infostatus=1_2_1&viewradio=0&viewstatus=&viewpos=, install it, and set the security version for projects to "2". Please refer to “15.9 Preventing Illegal Access to/Falsification of Data (Security Version)” in “GX Works3 Operating Manual” for details. For more information about the workaround, refer to the Mitsubishi Electric security advisory available at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2026-007_en.pdf".

    https://www.mitsubishielectric.com/fa/download/software/detailsearch.page?mode=software&kisyu=/plceng&shiryoid=1000001411&lang=2&select=0&softid=1&infostatus=1_2_1&viewradio=0&viewstatus=&viewpos=
  • WorkaroundMitsubishi Electric Motion Control Settings (Software packaged with GX Works3)cisa_csaf_ot

    For customers using Motion Control Settings (Software packaged with GX Works3), Please download version 1.070Y or later from the link "https://www.mitsubishielectric.com/fa/download/software/detailsearch.page?mode=software&kisyu=/ssc&shiryoid=1000000803&lang=2&select=0&softid=1&infostatus=1_8_1&viewradio=0&viewstatus=&viewpos=", install it, and set the security version for projects to "2". Please refer to “12.5 Preventing Illegal Access to/Falsification of Data (Security Version)” in “Motion Control Setting Function Help” for details. For more information about the workaround, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2026-007_en.pdf".

    https://www.mitsubishielectric.com/fa/download/software/detailsearch.page?mode=software&kisyu=/ssc&shiryoid=1000000803&lang=2&select=0&softid=1&infostatus=1_8_1&viewradio=0&viewstatus=&viewpos=
02

cvss

Technischer Schweregrad, 0–10. Eine Zeile je Quelle.

9.2
010

Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen⚠ Quellen uneinig · high–critical · 7.2–9.2

v3.18.8highCVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:Hsecondary · CISA US
v4.09.2criticalCVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:N/SC:N/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:Xsecondary · Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp
v4.07.2highCVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:N/SC:N/SI:H/SA:H/E:U/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:Xsecondary · CVSS-BT (t0sche)
03

SSVC

Eine Handlungsentscheidung — aus Ausnutzung und Auswirkung.

Exploitation: none · Automatable: no · Technical Impact: totalcoordinatorcisa_ssvcUS
04

schwächen

Die CWE-Schwächeklassen, zu denen dies gehört.

05

betroffene Produkte (4)

Betroffene Produkte und Versionsbereiche.

06

Advisories (1)

Hersteller- und Ökosystem-Meldungen dazu.

  • ICSA-26-260-02Mitsubishi Electric GX Works3 and Motion Control Settings2026-09-17icsa · cisa_csaf_otUS

    Successful exploitation of this vulnerability could allow a local attacker to successfully authenticate even with an invalid block password by executing the affected product and modify part of the executable module in memory, and thereby allows the attacker to view, tamper with, destroy, or delete control programs.

07

quellen

Welche Quellen diesen Datensatz belegen und wann.

veröffentlicht 2026-09-17geändert 2026-10-09
08

Referenzen (3) nvd

Externe Belege — Patches, Meldungen, Analysen.

scry

Angreifer nutzen Schwachstellen wie diese gegen im Internet exponierte Dienste aus. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.

Kostenloser Scan