CVE-2026-0667

criticalPriorität · verfolgen · 0EPSS 0.005 · 45. PerzentilEURUUS
grimoire priorityP2 · Scheduled
Exploitable?
—
no known exploitation
Likely / severe?
0.53% (45th) EPSS
CVSS 9.8 · critical
Is it mine?
18 products
Prüfe deine Angriffsfläche
Who says so?
4 sources
cnnvd · enisa_euvd · fstec_bdu · cisa_csaf_ot

EPSS · bewertet 2026-10-27

CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability that could cause arbitrary code execution, denial of service and loss of confidentiality & integrity when communicating over the Modbus TCP protocol.

01

Behebungen

Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.

Ein Hersteller-Fix ist verfügbar.

  • BehobenRemoteConnectcisa_csaf_ot

    Version R3.4.2 of RemoteConnect includes a fix for this vulnerability and is available for download here: https://www.se.com/ww/en/download/document/RemoteConnect/

    https://www.se.com/ww/en/download/document/RemoteConnect/
  • BehobenSCADAPack™ 47x firmware versions prior to 9.12.2 installed on SCADAPack™ 47x versions prior to R3.4.2cisa_csaf_ot

    Version R3.4.2 (Firmware version 9.12.2) of SCADAPack™ 47x and SCADAPack™ 47xi includes a fix for this vulnerability and is available for download here: https://www.se.com/ww/en/download/document/RemoteConnect/

    https://www.se.com/ww/en/download/document/RemoteConnect/
  • BehobenSCADAPack™ 47xi firmware versions prior to 9.12.2 installed on SCADAPack™ 47xi versions prior to R3.4.2cisa_csaf_ot

    Version R3.4.2 (Firmware version 9.12.2) of SCADAPack™ 47x and SCADAPack™ 47xi includes a fix for this vulnerability and is available for download here: https://www.se.com/ww/en/download/document/RemoteConnect/

    https://www.se.com/ww/en/download/document/RemoteConnect/
  • MitigationRemoteConnectcisa_csaf_ot

    If customers choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit: Follow the information according to SCADAPack™ Security Guidelines in section 8.3 Secured Communication. Also, apply the following standard practices to reduce the risk of exploit: • Setup network segmentation and implement the RTU firewall service to block all unauthorized access to services • Disable the logic debug service.

    https://www.se.com/ww/en/download/document/SCADAPack_Cybersecurity_Guide/
  • MitigationSCADAPack™cisa_csaf_ot

    Follow the information according to SCADAPack™ Security Guidelines in section 8.3 Secured Communication. Also, apply the following standard practices to reduce the risk of exploit • Setup network segmentation and implement the RTU firewall service to block all unauthorized access to services. • Disable the logic debug service.

    https://www.se.com/ww/en/download/document/SCADAPack_Cybersecurity_Guide/
  • MitigationSCADAPack™ 47x firmware versions prior to 9.12.2 installed on SCADAPack™ 47x versions prior to R3.4.2cisa_csaf_ot

    If customers choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit: Follow the information according to SCADAPack™ Security Guidelines in section 8.3 Secured Communication. Also, apply the following standard practices to reduce the risk of exploit: • Setup network segmentation and implement the RTU firewall service to block all unauthorized access to services • Disable the logic debug service.

    https://www.se.com/ww/en/download/document/SCADAPack_Cybersecurity_Guide/
  • MitigationSCADAPack™ 47xi firmware versions prior to 9.12.2 installed on SCADAPack™ 47xi versions prior to R3.4.2cisa_csaf_ot

    If customers choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit: Follow the information according to SCADAPack™ Security Guidelines in section 8.3 Secured Communication. Also, apply the following standard practices to reduce the risk of exploit: • Setup network segmentation and implement the RTU firewall service to block all unauthorized access to services • Disable the logic debug service.

    https://www.se.com/ww/en/download/document/SCADAPack_Cybersecurity_Guide/
02

cvss

Technischer Schweregrad, 0–10. Eine Zeile je Quelle.

9.8
010

Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen⚠ Quellen uneinig · high–critical · 8.1–9.8

v3.19.8criticalCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:Hsecondary · CISA US
v3.19.8criticalAV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:Hsecondary · FSTEC (BDU) RU
v4.09.3criticalCVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:Nsecondary · ENISA EU
v4.09.3criticalCVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:Xsecondary · cybersecurity@se.com
v4.08.1highCVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:U/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:Xsecondary · CVSS-BT (t0sche)
03

SSVC

Eine Handlungsentscheidung — aus Ausnutzung und Auswirkung.

Exploitation: none · Automatable: yes · Technical Impact: totalcoordinatorcisa_ssvcUS
04

schwächen

Die CWE-Schwächeklassen, zu denen dies gehört.

05

betroffene Produkte (18)

Betroffene Produkte und Versionsbereiche.

06

Advisories (1)

Hersteller- und Ökosystem-Meldungen dazu.

  • ICSA-26-076-02Schneider Electric SCADAPack and RemoteConnect2026-02-10icsa · cisa_csaf_otUS

    Schneider Electric is aware of a vulnerability in its SCADAPack™ x70 RTU products. The SCADAPack™ 47xi, SCADAPack™ 47x and SCADAPack™ 57x product are Remote Terminal Units that provide communication capabilities for remote monitoring and control. Failure to apply the remediations provided below may risk unauthorized access to your RTU, which could result in the possibility of denial of service and loss of confidentiality, integrity of the controller.

07

auch bekannt als (4)

Weitere Namen und Kennungen dieser Entität.

08

quellen

Welche Quellen diesen Datensatz belegen und wann.

veröffentlicht 2026-07-29geändert 2026-07-30
09

Referenzen (3)

Externe Belege — Patches, Meldungen, Analysen.

scry

Angreifer nutzen Schwachstellen wie diese gegen im Internet exponierte Dienste aus. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.

Kostenloser Scan