CVE-2025-7769

highPriorität · verfolgen · 17EPSS 0.194 · 97. PerzentilExploit · PoCEURUUS
grimoire priorityP1 · Urgent
Exploitable?
Public exploit
2 exploits · PoC
Likely / severe?
19.4% (97th) EPSS
CVSS 8.8 · high
Is it mine?
4 products
Prüfe deine Angriffsfläche
Who says so?
4 sources
cnnvd · enisa_euvd · fstec_bdu · cisa_csaf_ot

EPSS · bewertet 2026-10-27

Tigo Energy's CCA is vulnerable to a command injection vulnerability in the /cgi-bin/mobile_api endpoint when the DEVICE_PING command is called, allowing remote code execution due to improper handling of user input. When used with default credentials, this enables attackers to execute arbitrary commands on the device that could cause potential unauthorized access, service disruption, and data exposure.

01

Behebungen

Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.

Noch kein Hersteller-Fix; eine Mitigation ist verfügbar.

  • MitigationCloud Connect Advancedcisa_csaf_ot

    Tigo Energy is aware of these vulnerabilities and is actively working on a fix to address them.

02

cvss

Technischer Schweregrad, 0–10. Eine Zeile je Quelle.

8.8
010

Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen

v3.18.8highCVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:Hsecondary · CISA US
v3.18.8highAV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:Hsecondary · FSTEC (BDU) RU
v4.08.7highCVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:Nsecondary · ENISA EU
v4.08.7highCVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:Xsecondary · ics-cert@hq.dhs.gov US
v4.07.4highCVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:Xsecondary · CVSS-BT (t0sche)
03

SSVC

Eine Handlungsentscheidung — aus Ausnutzung und Auswirkung.

Exploitation: none · Automatable: no · Technical Impact: totalcoordinatorcisa_ssvcUS
04

schwächen

Die CWE-Schwächeklassen, zu denen dies gehört.

05

Exploits (2)

Öffentlicher Proof-of-Concept- und Exploit-Code.

06

betroffene Produkte (4)

Betroffene Produkte und Versionsbereiche.

07

Advisories (1)

Hersteller- und Ökosystem-Meldungen dazu.

  • ICSA-25-217-02Tigo Energy Cloud Connect Advanced (Update A)2025-08-05icsa · cisa_csaf_otUS

    Successful exploitation of these vulnerabilities could allow attackers to gain unauthorized administrative access using hard-coded credentials, escalate privileges to take full control of the device, modify system settings, disrupt solar energy production, interfere with safety mechanisms, execute arbitrary commands via command injection, cause service disruptions, expose sensitive data, and recreate valid session IDs to access sensitive device functions on connected solar inverter systems due to insecure session ID generation.

08

auch bekannt als (5)

Weitere Namen und Kennungen dieser Entität.

09

quellen

Welche Quellen diesen Datensatz belegen und wann.

veröffentlicht 2025-08-06geändert 2026-06-17
10

Referenzen (5)

Externe Belege — Patches, Meldungen, Analysen.

scry

Angreifer nutzen Schwachstellen wie diese gegen im Internet exponierte Dienste aus. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.

Kostenloser Scan