CVE-2025-55093

mediumPriorität · verfolgen · 21EPSS 0.003 · 24. PerzentilDEEUUS
grimoire priorityP3 · Track
Exploitable?
—
no known exploitation
Likely / severe?
0.31% (24th) EPSS
CVSS 5.3 · medium
Is it mine?
6 products
Prüfe deine Angriffsfläche
Who says so?
4 sources
cnnvd · enisa_euvd · nvd · sick_psirt

EPSS · bewertet 2026-10-27

In NetX Duo before 6.4.4, the networking support module for Eclipse Foundation ThreadX, there was a potential out of bound read issue in _nx_ipv4_packet_receive() when handling unicast DHCP messages that could cause corruption of 4 bytes of memory.

01

Behebungen

Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.

Noch kein Hersteller-Fix; eine Mitigation ist verfügbar.

  • MitigationSICK microScan3 EtherCAT all Firmware versionssick_psirt

    Ensure that an IP address is configured or assigned via DHCP and that the network is properly secured against unauthorized access so that only trusted entities have access to the devices. Furthermore, you should apply the following General Security Measures when operating the product to mitigate the associated security risk. The collected resources ”SICK Operating Guidelines” and ”ICS-CERT recommended practices on Industrial Security” could help to implement the general security practices.

  • MitigationSICK microScan3 Pro I/O all Firmware versionssick_psirt

    Ensure that an IP address is configured or assigned via DHCP and that the network is properly secured against unauthorized access so that only trusted entities have access to the devices. Furthermore, you should apply the following General Security Measures when operating the product to mitigate the associated security risk. The collected resources ”SICK Operating Guidelines” and ”ICS-CERT recommended practices on Industrial Security” could help to implement the general security practices.

  • MitigationSICK nanoScan3 Core I/O all Firmware versionssick_psirt

    Ensure that an IP address is configured or assigned via DHCP and that the network is properly secured against unauthorized access so that only trusted entities have access to the devices. Furthermore, you should apply the following General Security Measures when operating the product to mitigate the associated security risk. The collected resources ”SICK Operating Guidelines” and ”ICS-CERT recommended practices on Industrial Security” could help to implement the general security practices.

  • MitigationSICK nanoScan3 Pro I/O all Firmware versionssick_psirt

    Ensure that an IP address is configured or assigned via DHCP and that the network is properly secured against unauthorized access so that only trusted entities have access to the devices. Furthermore, you should apply the following General Security Measures when operating the product to mitigate the associated security risk. The collected resources ”SICK Operating Guidelines” and ”ICS-CERT recommended practices on Industrial Security” could help to implement the general security practices.

02

cvss

Technischer Schweregrad, 0–10. Eine Zeile je Quelle.

6.9
010

Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen⚠ Quellen uneinig · low–medium · 2.7–6.9

v3.15.3mediumCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:Nprimary · NVD / NIST USAusnutzbarkeit 3.9 · Auswirkung 1.4
v3.15.3mediumCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:Nsecondary · SICK PSIRT DE
v4.06.9mediumCVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:Nsecondary · ENISA EU
v4.06.9mediumCVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:Xsecondary · emo@eclipse.org
v4.02.7lowCVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N/E:U/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:Xsecondary · CVSS-BT (t0sche)
03

SSVC

Eine Handlungsentscheidung — aus Ausnutzung und Auswirkung.

Exploitation: none · Automatable: yes · Technical Impact: partialcoordinatorcisa_ssvcUS
04

schwächen

Die CWE-Schwächeklassen, zu denen dies gehört.

05

betroffene Produkte (6)

Betroffene Produkte und Versionsbereiche.

06

Advisories (1)

Hersteller- und Ökosystem-Meldungen dazu.

  • SCA-2026-0003Vulnerability affecting SICK nanoScan3 and microScan32026-01-26csaf · sick_psirtDE

    SICK has identified a 3rd party vulnerability (CVE-2025-55093) in the nanoScan3 and microScan3. Only specific variants within the microScan3 and nanoScan3 families are affected by CVE-2025-55093. The underlying issue in the NetX Duo networking module could, under specific conditions, cause the device to enter a safe error state that requires a restart. SICK recommends applying the mitigation for CVE-2025-55093.

07

auch bekannt als (2)

Weitere Namen und Kennungen dieser Entität.

08

quellen

Welche Quellen diesen Datensatz belegen und wann.

veröffentlicht 2025-10-17geändert 2026-06-17
10

Referenzen (5)

Externe Belege — Patches, Meldungen, Analysen.

scry

Angreifer nutzen Schwachstellen wie diese gegen im Internet exponierte Dienste aus. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.

Kostenloser Scan