CVE-2025-43874

highPriorität · verfolgen · 0US
grimoire priorityP2 · Scheduled
Exploitable?
—
no known exploitation
Likely / severe?
— EPSS
CVSS 8.8 · high
Is it mine?
12 products
Prüfe deine Angriffsfläche
Who says so?
1 sources
cisa_csaf_ot

Keine Beschreibung erfasst.

01

Behebungen

Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.

Ein Hersteller-Fix ist verfügbar.

  • BehobeniSTAR Edge G2cisa_csaf_ot

    Upgrade iSTAR Ultra G2, iSTAR Ultra G2 SE, iSTAR Edge G2 to version 6.9.3 or greater.

  • BehobeniSTAR Ultracisa_csaf_ot

    Upgrade iSTAR Ultra, iSTAR Ultra SE, iSTAR Ultra LT to version 6.9.7.CU01 or greater.

  • BehobeniSTAR Ultra G2cisa_csaf_ot

    Upgrade iSTAR Ultra G2, iSTAR Ultra G2 SE, iSTAR Edge G2 to version 6.9.3 or greater.

  • BehobeniSTAR Ultra G2 SEcisa_csaf_ot

    Upgrade iSTAR Ultra G2, iSTAR Ultra G2 SE, iSTAR Edge G2 to version 6.9.3 or greater.

  • BehobeniSTAR Ultra LTcisa_csaf_ot

    Upgrade iSTAR Ultra, iSTAR Ultra SE, iSTAR Ultra LT to version 6.9.7.CU01 or greater.

  • BehobeniSTAR Ultra SEcisa_csaf_ot

    Upgrade iSTAR Ultra, iSTAR Ultra SE, iSTAR Ultra LT to version 6.9.7.CU01 or greater.

  • MitigationiSTAR Edge G2cisa_csaf_ot

    Johnson Controls recommends taking steps to minimize risks to all building automation systems in alignment with CISA's guidance.

  • MitigationiSTAR Ultracisa_csaf_ot

    Johnson Controls recommends taking steps to minimize risks to all building automation systems in alignment with CISA's guidance.

  • MitigationiSTAR Ultra G2cisa_csaf_ot

    Johnson Controls recommends taking steps to minimize risks to all building automation systems in alignment with CISA's guidance.

  • MitigationiSTAR Ultra G2 SEcisa_csaf_ot

    Johnson Controls recommends taking steps to minimize risks to all building automation systems in alignment with CISA's guidance.

  • MitigationiSTAR Ultra LTcisa_csaf_ot

    Johnson Controls recommends taking steps to minimize risks to all building automation systems in alignment with CISA's guidance.

  • MitigationiSTAR Ultra SEcisa_csaf_ot

    Johnson Controls recommends taking steps to minimize risks to all building automation systems in alignment with CISA's guidance.

02

cvss

Technischer Schweregrad, 0–10. Eine Zeile je Quelle.

8.8
010

Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen

v3.18.8highCVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:Hsecondary · CISA US
03

schwächen

Die CWE-Schwächeklassen, zu denen dies gehört.

04

betroffene Produkte (12)

Betroffene Produkte und Versionsbereiche.

05

Advisories (1)

Hersteller- und Ökosystem-Meldungen dazu.

  • ICSA-25-345-02Johnson Controls iSTAR Ultra2025-12-11icsa · cisa_csaf_otUS

    Successful exploitation of these vulnerabilities could allow an attacker to modify firmware and gain full access to the device.

06

quellen

Welche Quellen diesen Datensatz belegen und wann.

veröffentlicht —geändert —
07

Referenzen

Externe Belege — Patches, Meldungen, Analysen.

Keine Referenzen erfasst.

scry

Angreifer nutzen Schwachstellen wie diese gegen im Internet exponierte Dienste aus. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.

Kostenloser Scan