CVE-2025-4373
mediumPriorität · verfolgen · 0EPSS 0.006 · 50. PerzentilDEEUFRNLRUUSEPSS · bewertet 2026-10-27
A flaw was found in GLib, which is vulnerable to an integer overflow in the g_string_insert_unichar() function. When the position at which to insert the character is large, the position will overflow, leading to a buffer underwrite.
Behebungen
Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.
Ein Hersteller-Fix ist verfügbar.
- BehobenRUGGEDCOM RST2428P (6GK6242-6PA00)siemens_psirt
Update to V3.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109997626/ - BehobenSCALANCE XC-300/XR-300/XC-400/XR-500WG/XR-500 familysiemens_psirt
See Section Additional Information.
- BehobenSCALANCE XCH328 (6GK5328-4TS01-2EC2)siemens_psirt
Update to V3.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109997626/ - BehobenSCALANCE XCM324 (6GK5324-8TS01-2AC2)siemens_psirt
Update to V3.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109997626/ - BehobenSCALANCE XCM328 (6GK5328-4TS01-2AC2)siemens_psirt
Update to V3.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109997626/ - BehobenSCALANCE XCM332 (6GK5332-0GA01-2AC2)siemens_psirt
Update to V3.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109997626/ - BehobenSCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)siemens_psirt
Update to V3.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109997626/ - BehobenSCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)siemens_psirt
Update to V3.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109997626/ - BehobenSCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)siemens_psirt
Update to V3.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109997626/ - BehobenSCALANCE XRM334 (230V AC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-3AR3)siemens_psirt
Update to V3.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109997626/ - BehobenSCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)siemens_psirt
Update to V3.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109997626/ - BehobenSCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)siemens_psirt
Update to V3.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109997626/ - BehobenSCALANCE XRM334 (24V DC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-2AR3)siemens_psirt
Update to V3.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109997626/ - BehobenSCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)siemens_psirt
Update to V3.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109997626/ - BehobenSCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)siemens_psirt
Update to V3.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109997626/ - BehobenSCALANCE XRM334 (2x230V AC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-4AR3)siemens_psirt
Update to V3.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109997626/ - BehobenRUGGEDCOM RST2428P (6GK6242-6PA00)cisa_csaf_ot
Update to V3.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109997626/ - BehobenSCALANCE XC-300/XR-300/XC-400/XR-500WG/XR-500 familycisa_csaf_ot
See Section Additional Information.
- BehobenSCALANCE XCH328 (6GK5328-4TS01-2EC2)cisa_csaf_ot
Update to V3.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109997626/ - BehobenSCALANCE XCM324 (6GK5324-8TS01-2AC2)cisa_csaf_ot
Update to V3.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109997626/ - BehobenSCALANCE XCM328 (6GK5328-4TS01-2AC2)cisa_csaf_ot
Update to V3.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109997626/ - BehobenSCALANCE XCM332 (6GK5332-0GA01-2AC2)cisa_csaf_ot
Update to V3.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109997626/ - BehobenSCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)cisa_csaf_ot
Update to V3.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109997626/ - BehobenSCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)cisa_csaf_ot
Update to V3.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109997626/ - BehobenSCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)cisa_csaf_ot
Update to V3.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109997626/ - BehobenSCALANCE XRM334 (230V AC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-3AR3)cisa_csaf_ot
Update to V3.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109997626/ - BehobenSCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)cisa_csaf_ot
Update to V3.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109997626/ - BehobenSCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)cisa_csaf_ot
Update to V3.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109997626/ - BehobenSCALANCE XRM334 (24V DC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-2AR3)cisa_csaf_ot
Update to V3.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109997626/ - BehobenSCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)cisa_csaf_ot
Update to V3.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109997626/ - BehobenSCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)cisa_csaf_ot
Update to V3.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109997626/ - BehobenSCALANCE XRM334 (2x230V AC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-4AR3)cisa_csaf_ot
Update to V3.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109997626/ - MitigationSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0)siemens_psirt
Limit access to the interactive shell of the additional GNU/Linux subssytem to trusted personnel only.
- MitigationSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AC0)siemens_psirt
Limit access to the interactive shell of the additional GNU/Linux subssytem to trusted personnel only.
- MitigationSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AB0)siemens_psirt
Limit access to the interactive shell of the additional GNU/Linux subssytem to trusted personnel only.
- MitigationSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AC0)siemens_psirt
Limit access to the interactive shell of the additional GNU/Linux subssytem to trusted personnel only.
- MitigationSIPLUS S7-1500 CPU 1518-4 PN/DP MFP (6AG1518-4AX00-4AC0)siemens_psirt
Limit access to the interactive shell of the additional GNU/Linux subssytem to trusted personnel only.
- MitigationSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0)cisa_csaf_ot
Limit access to the interactive shell of the additional GNU/Linux subssytem to trusted personnel only.
- MitigationSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AC0)cisa_csaf_ot
Limit access to the interactive shell of the additional GNU/Linux subssytem to trusted personnel only.
- MitigationSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AB0)cisa_csaf_ot
Limit access to the interactive shell of the additional GNU/Linux subssytem to trusted personnel only.
- MitigationSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AC0)cisa_csaf_ot
Limit access to the interactive shell of the additional GNU/Linux subssytem to trusted personnel only.
- MitigationSIPLUS S7-1500 CPU 1518-4 PN/DP MFP (6AG1518-4AX00-4AC0)cisa_csaf_ot
Limit access to the interactive shell of the additional GNU/Linux subssytem to trusted personnel only.
- Kein Fix verfügbarSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0)siemens_psirt
Currently no fix is available
- Kein Fix verfügbarSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AC0)siemens_psirt
Currently no fix is available
- Kein Fix verfügbarSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AB0)siemens_psirt
Currently no fix is available
- Kein Fix verfügbarSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AC0)siemens_psirt
Currently no fix is available
- Kein Fix verfügbarSIPLUS S7-1500 CPU 1518-4 PN/DP MFP (6AG1518-4AX00-4AC0)siemens_psirt
Currently no fix is available
- Kein Fix verfügbarSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0)cisa_csaf_ot
Currently no fix is available
- Kein Fix verfügbarSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AC0)cisa_csaf_ot
Currently no fix is available
- Kein Fix verfügbarSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AB0)cisa_csaf_ot
Currently no fix is available
- Kein Fix verfügbarSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AC0)cisa_csaf_ot
Currently no fix is available
- Kein Fix verfügbarSIPLUS S7-1500 CPU 1518-4 PN/DP MFP (6AG1518-4AX00-4AC0)cisa_csaf_ot
Currently no fix is available
cvss
Technischer Schweregrad, 0–10. Eine Zeile je Quelle.
Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen
SSVC
Eine Handlungsentscheidung — aus Ausnutzung und Auswirkung.
schwächen
Die CWE-Schwächeklassen, zu denen dies gehört.
betroffene Produkte (226)
Betroffene Produkte und Versionsbereiche.
Advisories (11)
Hersteller- und Ökosystem-Meldungen dazu.
- NCSC-2025-0187Kwetsbaarheden verholpen in Siemens productenNL2025-06-10csaf · ncsc_nlNL
Siemens heeft kwetsbaarheden verholpen in diverse producten als RUGGEDCOM, SCALANCE, SIMATIC en Tecnomatix
- NCSC-2025-0330Kwetsbaarheden verholpen in Oracle Communications productenNL2025-10-23csaf · ncsc_nlNL
Oracle heeft meerdere kwetsbaarheden verholpen in zijn Communications producten, waaronder de Unified Assurance en Cloud Native Core.
- SSA-082556SSA-082556: Vulnerabilities in the additional GNU/Linux subsystem of the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP V3.1.52025-06-10csaf · siemens_psirtDE
Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the firmware version V3.1.5 for the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP (incl. SIPLUS variant). Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fixes and recommends specific mitigations for products where fixes are not or not yet available. SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP V3.1.5 is no longer maintained and there won't be any update to the CVE list anymore. Please update to the latest version. Note: This SSA advises vulnerabilities for firmware version V3.1.5 only; for version V3.1.6 refer to SSA-019113.
- SSA-089022SSA-089022: Multiple Vulnerabilities in Third-Party Components in SINEC OS before V3.32026-01-28csaf · siemens_psirtDE
SINEC OS before V3.3 contains third-party components with multiple vulnerabilities. Siemens has released new versions for the affected products and recommends to update to the latest versions.
- WID-SEC-W-2025-1546Red Hat Enterprise Linux (GLib): Schwachstelle ermöglicht Denial of ServiceDeutsch2025-07-14csaf · cert_bundDE
Ein entfernter, anonymer Angreifer kann eine Schwachstelle in Red Hat Enterprise Linux GLib ausnutzen, um einen Denial of Service Angriff durchzuführen.
- WID-SEC-W-2025-1905IBM QRadar SIEM Komponente: Mehrere SchwachstellenDeutsch2025-08-25csaf · cert_bundDE
Ein Angreifer kann mehrere Schwachstellen in IBM QRadar SIEM Komponenten ausnutzen, um Daten zu manipulieren, um einen Denial of Service Angriff durchzuführen, um beliebigen Programmcode auszuführen, um Sicherheitsvorkehrungen zu umgehen, und um Informationen offenzulegen.
- WID-SEC-W-2025-2361Oracle Communications: Mehrere SchwachstellenDeutsch2025-10-21csaf · cert_bundDE
Ein entfernter, anonymer oder authentisierter Angreifer kann mehrere Schwachstellen in Oracle Communications ausnutzen, um die Vertraulichkeit, Integrität und Verfügbarkeit zu gefährden.
- WID-SEC-W-2026-0349Dell Avamar und NetWorker: Mehrere SchwachstellenDeutsch2026-02-09csaf · cert_bundDE
Ein Angreifer kann mehrere Schwachstellen in Dell Avamar und Dell NetWorker ausnutzen, um Angriffe zu starten, die die Integrität, Vertraulichkeit und Verfügbarkeit von Systemen beeinträchtigen.
- ICSA-25-162-05Siemens SIMATIC S7-1500 CPU family2025-06-10icsa · cisa_csaf_otUS
Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the firmware version V3.1.5 for the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP (incl. SIPLUS variant). Siemens is preparing fix versions and recommends countermeasures for products where fixes are not, or not yet available.
- ICSA-26-043-06Siemens SINEC OS2026-01-28icsa · cisa_csaf_otUS
SINEC OS before V3.3 contains third-party components with multiple vulnerabilities. Siemens has released new versions for the affected products and recommends to update to the latest versions.
- CERTFR-2026-AVI-1385Multiples vulnérabilités dans les produits VMwareFrançais2026-10-26vendor · certfrFR
auch bekannt als (4)
Weitere Namen und Kennungen dieser Entität.
quellen
Welche Quellen diesen Datensatz belegen und wann.
Referenzen (52)
Externe Belege — Patches, Meldungen, Analysen.
- https://access.redhat.com/errata/RHSA-2025:10855cnnvd
- https://access.redhat.com/errata/RHSA-2025:11140cnnvd
- https://access.redhat.com/errata/RHSA-2025:11327cnnvd
- https://access.redhat.com/errata/RHSA-2025:11373cnnvd
- https://access.redhat.com/errata/RHSA-2025:11374cnnvd
- https://access.redhat.com/errata/RHSA-2025:11662cnnvd
- https://access.redhat.com/errata/RHSA-2025:12275cnnvd
- https://access.redhat.com/errata/RHSA-2025:13335cnnvd
Angreifer nutzen Schwachstellen wie diese gegen im Internet exponierte Dienste aus. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.
Kostenloser Scan