CVE-2025-40763

highPriorität · verfolgen · 0EPSS 0.001 · 4. PerzentilDEEUNLRUUS
grimoire priorityP2 · Scheduled
Exploitable?
—
no known exploitation
Likely / severe?
0.15% (4th) EPSS
CVSS 7.8 · high
Is it mine?
87 products
Prüfe deine Angriffsfläche
Who says so?
6 sources
cnnvd · enisa_euvd · fstec_bdu · cisa_csaf_ot

EPSS · bewertet 2026-10-23

A vulnerability has been identified in Altair Grid Engine (All versions < V2026.0.0). Affected products do not properly validate environment variables when loading shared libraries, allowing path hijacking through malicious library substitution. This could allow a local attacker to execute arbitrary code with superuser privileges by manipulating the environment variable and placing a malicious library in the controlled path.

01

Behebungen

Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.

Ein Hersteller-Fix ist verfügbar.

  • BehobenAltair Grid Enginesiemens_psirt

    Update to V2026.0.0 or later version

    https://altairone.com/Marketplace
  • BehobenAltair Grid Enginecisa_csaf_ot

    Update to V2026.0.0 or later version

    https://altairone.com/Marketplace
  • MitigationAltair Grid Enginesiemens_psirt

    For non Windows clusters remove the setuid-root bit from the "sgepasswd" binary for all installed architectures: chmod u-s $SGE_ROOT/bin/&lt;arch&gt;/sgepasswd.

  • MitigationAltair Grid Enginecisa_csaf_ot

    For non Windows clusters remove the setuid-root bit from the "sgepasswd" binary for all installed architectures: chmod u-s $SGE_ROOT/bin/&lt;arch&gt;/sgepasswd.

02

cvss

Technischer Schweregrad, 0–10. Eine Zeile je Quelle.

8.5
010

Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen⚠ Quellen uneinig · medium–high · 5.9–8.5

v3.17.8highCVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:Hsecondary · NCSC-NL NL
v3.17.8highAV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:Hsecondary · FSTEC (BDU) RU
v3.17.8highCVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:Hsecondary · productcert@siemens.com DEAusnutzbarkeit 1.8 · Auswirkung 5.9
v3.17.8highCVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:Hsecondary · Siemens ProductCERT DE
v3.17.8highCVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:Hsecondary · CISA US
v4.08.5highCVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:Nsecondary · ENISA EU
v4.08.5highCVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:Xsecondary · productcert@siemens.com DE
v4.05.9mediumCVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:U/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:Xsecondary · CVSS-BT (t0sche)
03

SSVC

Eine Handlungsentscheidung — aus Ausnutzung und Auswirkung.

Exploitation: none · Automatable: no · Technical Impact: totalcoordinatorcisa_ssvcUS
04

schwächen

Die CWE-Schwächeklassen, zu denen dies gehört.

05

betroffene Produkte (87)

Betroffene Produkte und Versionsbereiche.

06

Advisories (3)

Hersteller- und Ökosystem-Meldungen dazu.

  • NCSC-2025-0357Kwetsbaarheden verholpen in Siemens productenNL2025-11-11csaf · ncsc_nlNL

    Siemens heeft kwetsbaarheden verholpen in diverse producten als Altair Grid Engine, COMOS, LOGO, SICAM, SIDOOR, SIMATIC, SIPLUS, Spectrum Power en Solid Edge.

  • SSA-514895SSA-514895: Multiple Vulnerabilities in Altair Grid Engine V2025.1.02025-11-11csaf · siemens_psirtDE

    Altair Grid Engine contain multiple vulnerabilities that could allow an attacker to escalate privileges and execute arbitrary code with superuser permissions. Siemens has released a new version for Altair Grid Engine and recommends to update to the latest version.

  • ICSA-25-317-16Siemens Altair Grid Engine2025-11-11icsa · cisa_csaf_otUS

    Altair Grid Engine contain multiple vulnerabilities that could allow an attacker to escalate privileges and execute arbitrary code with superuser permissions. Siemens has released a new version for Altair Grid Engine and recommends to update to the latest version.

07

auch bekannt als (5)

Weitere Namen und Kennungen dieser Entität.

08

quellen

Welche Quellen diesen Datensatz belegen und wann.

09

Referenzen (4)

Externe Belege — Patches, Meldungen, Analysen.

scry

Angreifer nutzen Schwachstellen wie diese gegen im Internet exponierte Dienste aus. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.

Kostenloser Scan