CVE-2025-39841
highPriorität · verfolgen · 31EPSS 0.005 · 41. PerzentilDEEUNLRUUSEPSS · bewertet 2026-10-23
In the Linux kernel, the following vulnerability has been resolved: scsi: lpfc: Fix buffer free/clear order in deferred receive path Fix a use-after-free window by correcting the buffer release sequence in the deferred receive path. The code freed the RQ buffer first and only then cleared the context pointer under the lock. Concurrent paths (e.g., ABTS and the repost path) also inspect and release the same pointer under the lock, so the old order could lead to double-free/UAF. Note that the repost path already uses the correct pattern: detach the pointer under the lock, then free it after dropping the lock. The deferred path should do the same.
Behebungen
Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.
Ein Hersteller-Fix ist verfügbar.
- BehobenSIMATIC CN 4100siemens_psirt
Update to V5.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109814144/ - BehobenRUGGEDCOM RST2428P (6GK6242-6PA00)siemens_psirt
Update to V3.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109997626/ - BehobenSCALANCE XC-300/XR-300/XC-400/XR-500WG/XR-500 familysiemens_psirt
See Section Additional Information.
- BehobenSCALANCE XCH328 (6GK5328-4TS01-2EC2)siemens_psirt
Update to V3.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109997626/ - BehobenSCALANCE XCM324 (6GK5324-8TS01-2AC2)siemens_psirt
Update to V3.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109997626/ - BehobenSCALANCE XCM328 (6GK5328-4TS01-2AC2)siemens_psirt
Update to V3.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109997626/ - BehobenSCALANCE XCM332 (6GK5332-0GA01-2AC2)siemens_psirt
Update to V3.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109997626/ - BehobenSCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)siemens_psirt
Update to V3.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109997626/ - BehobenSCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)siemens_psirt
Update to V3.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109997626/ - BehobenSCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)siemens_psirt
Update to V3.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109997626/ - BehobenSCALANCE XRM334 (230V AC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-3AR3)siemens_psirt
Update to V3.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109997626/ - BehobenSCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)siemens_psirt
Update to V3.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109997626/ - BehobenSCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)siemens_psirt
Update to V3.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109997626/ - BehobenSCALANCE XRM334 (24V DC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-2AR3)siemens_psirt
Update to V3.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109997626/ - BehobenSCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)siemens_psirt
Update to V3.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109997626/ - BehobenSCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)siemens_psirt
Update to V3.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109997626/ - BehobenSCALANCE XRM334 (2x230V AC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-4AR3)siemens_psirt
Update to V3.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109997626/ - BehobenRUGGEDCOM RST2428P (6GK6242-6PA00)cisa_csaf_ot
Update to V3.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109997626/ - BehobenSCALANCE XC-300/XR-300/XC-400/XR-500WG/XR-500 familycisa_csaf_ot
See Section Additional Information.
- BehobenSCALANCE XCH328 (6GK5328-4TS01-2EC2)cisa_csaf_ot
Update to V3.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109997626/ - BehobenSCALANCE XCM324 (6GK5324-8TS01-2AC2)cisa_csaf_ot
Update to V3.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109997626/ - BehobenSCALANCE XCM328 (6GK5328-4TS01-2AC2)cisa_csaf_ot
Update to V3.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109997626/ - BehobenSCALANCE XCM332 (6GK5332-0GA01-2AC2)cisa_csaf_ot
Update to V3.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109997626/ - BehobenSCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)cisa_csaf_ot
Update to V3.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109997626/ - BehobenSCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)cisa_csaf_ot
Update to V3.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109997626/ - BehobenSCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)cisa_csaf_ot
Update to V3.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109997626/ - BehobenSCALANCE XRM334 (230V AC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-3AR3)cisa_csaf_ot
Update to V3.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109997626/ - BehobenSCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)cisa_csaf_ot
Update to V3.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109997626/ - BehobenSCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)cisa_csaf_ot
Update to V3.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109997626/ - BehobenSCALANCE XRM334 (24V DC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-2AR3)cisa_csaf_ot
Update to V3.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109997626/ - BehobenSCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)cisa_csaf_ot
Update to V3.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109997626/ - BehobenSCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)cisa_csaf_ot
Update to V3.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109997626/ - BehobenSCALANCE XRM334 (2x230V AC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-4AR3)cisa_csaf_ot
Update to V3.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109997626/ - BehobenSIMATIC CN 4100cisa_csaf_ot
Update to V5.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109814144/
cvss
Technischer Schweregrad, 0–10. Eine Zeile je Quelle.
Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen⚠ Quellen uneinig · medium–critical · 5.5–9.8
SSVC
Eine Handlungsentscheidung — aus Ausnutzung und Auswirkung.
schwächen
Die CWE-Schwächeklassen, zu denen dies gehört.
betroffene Produkte (141)
Betroffene Produkte und Versionsbereiche.
Advisories (7)
Hersteller- und Ökosystem-Meldungen dazu.
- NCSC-2026-0147Kwetsbaarheden verholpen in Siemens-productenNL2026-05-13csaf · ncsc_nlNL
Siemens heeft kwetsbaarheden verholpen in verschillende (OT-)producten. Het gaat onder andere om producten in de Siemens RUGGEDCOM-, SCALANCE-, SIMATIC-, SIMIT-, SINAMICS-, SIPROTEC-, SENTRON- en Solid Edge-productreeksen.
- SSA-032379SSA-032379: Multiple Vulnerabilities in SIMATIC CN 4100 Before V5.02026-05-12csaf · siemens_psirtDE
SIMATIC CN 4100 contains multiple vulnerabilities which could potentially lead to a compromise in availability, integrity and confidentiality. Siemens has released a new version for SIMATIC CN 4100 and recommends to update to the latest version.
- SSA-089022SSA-089022: Multiple Vulnerabilities in Third-Party Components in SINEC OS before V3.32026-01-28csaf · siemens_psirtDE
SINEC OS before V3.3 contains third-party components with multiple vulnerabilities. Siemens has released new versions for the affected products and recommends to update to the latest versions.
- WID-SEC-W-2025-2099Linux Kernel: Mehrere SchwachstellenDeutsch2025-09-21csaf · cert_bundDE
Ein Angreifer kann mehrere Schwachstellen im Linux Kernel ausnutzen, um einen Denial of Service Angriff durchzuführen oder nicht näher beschriebene Auswirkungen zu erzielen.
- WID-SEC-W-2026-0349Dell Avamar und NetWorker: Mehrere SchwachstellenDeutsch2026-02-09csaf · cert_bundDE
Ein Angreifer kann mehrere Schwachstellen in Dell Avamar und Dell NetWorker ausnutzen, um Angriffe zu starten, die die Integrität, Vertraulichkeit und Verfügbarkeit von Systemen beeinträchtigen.
- ICSA-26-043-06Siemens SINEC OS2026-01-28icsa · cisa_csaf_otUS
SINEC OS before V3.3 contains third-party components with multiple vulnerabilities. Siemens has released new versions for the affected products and recommends to update to the latest versions.
- ICSA-26-134-10Siemens SIMATIC2026-05-12icsa · cisa_csaf_otUS
SIMATIC CN 4100 contains multiple vulnerabilities which could potentially lead to a compromise in availability, integrity and confidentiality. Siemens has released a new version for SIMATIC CN 4100 and recommends to update to the latest version.
auch bekannt als (4)
Weitere Namen und Kennungen dieser Entität.
quellen
Welche Quellen diesen Datensatz belegen und wann.
Referenzen (30)
Externe Belege — Patches, Meldungen, Analysen.
- https://git.kernel.org/stable/c/367cb5ffd8a8a4c85dc89f55e7fa7cc191425b11cnnvd
- https://git.kernel.org/stable/c/55658c7501467ca9ef3bd4453dd920010db8bc13cnnvd
- https://git.kernel.org/stable/c/897f64b01c1249ac730329b83f4f40bab71e86c7cnnvd
- https://git.kernel.org/stable/c/95b63d15fce5c54a73bbf195e1aacb5a75b128e2cnnvd
- https://git.kernel.org/stable/c/9dba9a45c348e8460da97c450cddf70b2056deb3cnnvd
- https://git.kernel.org/stable/c/ab34084f42ee06a9028d67c78feafb911d33d111cnnvd
- https://git.kernel.org/stable/c/baa39f6ad79d372a6ce0aa639fbb2f1578479f57cnnvd
- https://git.kernel.org/stable/c/d96cc9a1b57725930c60b607423759d563b4d900cnnvd
Angreifer nutzen Schwachstellen wie diese gegen im Internet exponierte Dienste aus. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.
Kostenloser Scan