CVE-2025-32463

highPriorität · handeln · 90OT-Risiko · kritischKEV · ausgenutztEPSS 0.555 · 99. PerzentilExploit · funktionalDEEURUUS
grimoire priorityP0 · Act now
Exploitable?
Yes · in the wild
CISA KEV · 71 exploits · funktional
Likely / severe?
55.5% (99th) EPSS
CVSS 7.8 · high
Is it mine?
96 products
Prüfe deine Angriffsfläche
Who says so?
7 sources
cnnvd · enisa_euvd · fstec_bdu · cert_bund

hinzugefügt 2025-09-29beheben bis 2025-10-20

erforderliche Maßnahme Apply mitigations per vendor instructions, follow applicable BOD 22-01 guidance for cloud services, or discontinue use of the product if mitigations are unavailable.

EPSS · bewertet 2026-10-24

Sudo Inclusion of Functionality from Untrusted Control Sphere Vulnerability

Sudo before 1.9.17p1 allows local users to obtain root access because /etc/nsswitch.conf from a user-controlled directory is used with the --chroot option.

01

Behebungen

Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.

Ein Hersteller-Fix ist verfügbar.

  • BehobenSICK SID121 LFT with Firmware < 4.2.7sick_psirt

    It is strongly recommended to upgrade to the latest version (4.2.7)

  • BehobenSICK SID121 with Firmware < 4.2.7sick_psirt

    It is strongly recommended to upgrade to the latest version (4.2.7)

  • BehobenSICK SID71 LFT with Firmware < 4.2.7sick_psirt

    It is strongly recommended to upgrade to the latest version (4.2.7)

  • BehobenSICK SID71 with Firmware < 4.2.7sick_psirt

    It is strongly recommended to upgrade to the latest version (4.2.7)

  • BehobenEndress+Hauser MCS200HW with firmware <1.11.5.6Rsick_psirt

    The display unit's firmware versions below 4.3.4 are affected. To address the vulnerability, customers are strongly recommended to update the display unit of their devices to firmware version 4.3.4. Endress+Hauser will include this firmware version in the MCS200HW products starting with version 1.11.5.6R. Alternatively, customers can contact Endress+Hauser directly to obtain the updated display firmware, or download the original firmware - including update instructions - from the Phoenix Contact website referenced below.

  • Behobenwago_psirt

    Update to Firmware version 04.08.01 (FW30) or higher.

  • BehobenEndress+Hauser MCS200HW with firmware <1.11.5.6Rendress_hauser_psirt

    The display unit's firmware versions below 4.3.4 are affected. To address the vulnerability, customers are strongly recommended to update the display unit of their devices to firmware version 4.3.4. Endress+Hauser will include this firmware version in the MCS200HW products starting with version 1.11.5.6R. Alternatively, customers can contact Endress+Hauser directly to obtain the updated display firmware, or download the original firmware - including update instructions - from the Phoenix Contact website referenced below.

  • Mitigationwago_psirt

    Until Firmware 30 is available the vulnerability can be mitigated by installing an ipk to update sudo to 1.9.17p1. The ipk is available through the WAGO download center.

    https://downloadcenter.wago.com/wago/software/details/mckqrqwdtxpqe857kf8
  • MitigationEndress+Hauser MCS200HW with firmware <1.11.5.6Rendress_hauser_psirt

    As a temporary mitigation measure, both system and network access to the affected functionality should be strictly restricted. Access should be limited to authorized personnel only, and exposure to external or untrusted networks should be minimized or fully blocked until an update of the display firmware has been completed.

02

cvss

Technischer Schweregrad, 0–10. Eine Zeile je Quelle.

9.3
010

Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen⚠ Quellen uneinig · high–critical · 7.8–9.3

v3.17.8highCVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:Hprimary · NVD / NIST USAusnutzbarkeit 1.8 · Auswirkung 5.9
v3.19.3criticalAV:L/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:Hsecondary · FSTEC (BDU) RU
v3.19.3criticalCVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:Hsecondary · ENISA EU
v3.19.3criticalCVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:Hsecondary · cve@mitre.org USAusnutzbarkeit 2.5 · Auswirkung 6
v3.17.8highCVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:Hsecondary · WAGO PSIRT DE
v3.19.3criticalCVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:Hsecondary · SICK PSIRT DE
v3.17.8highCVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:Hsecondary · Endress+Hauser PSIRT DE
v3.17.8highCVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:Hsecondary · CVSS-BT (t0sche)
03

SSVC

Eine Handlungsentscheidung — aus Ausnutzung und Auswirkung.

Exploitation: active · Automatable: no · Technical Impact: totalcoordinatorcisa_ssvcUS
04

schwächen

Die CWE-Schwächeklassen, zu denen dies gehört.

05

Exploits (71)

Öffentlicher Proof-of-Concept- und Exploit-Code.

06

betroffene Produkte (96)

Betroffene Produkte und Versionsbereiche.

20 von 96 angezeigt
07

Advisories (5)

Hersteller- und Ökosystem-Meldungen dazu.

  • SCA-2025-0012Sudo vulnerability affects SICK SID products2025-10-27csaf · sick_psirtDE

    SICK SID products are affected by the sudo vulnerability CVE-2025-32463. SICK strongly recommends to update to the latest version to mitigate the risk.

  • SCA-2026-0007Sudo vulnerability affects Endress+Hauser MCS200HW2026-04-21csaf · sick_psirtDE

    The display unit of the Endress+Hauser MCS200HW is affected by a sudo chroot vulnerability.

  • VDE-2025-082WAGO: Critical sudo Vulnerability in Multiple Products2025-09-08csaf · wago_psirtDE

    A vulnerability in sudo allows a low privileged attacker to execute commands with root rights.

  • VDE-2026-032Endress+Hauser: sudo vulnerability affects Endress+Hauser MCS200HW2026-04-21csaf · endress_hauser_psirtDE

    The display unit of the Endress+Hauser MCS200HW is affected by a sudo chroot vulnerability.

  • WID-SEC-W-2025-1428sudo: Mehrere SchwachstellenDeutsch2025-06-30csaf · cert_bundDE

    Ein lokaler Angreifer kann mehrere Schwachstellen in sudo ausnutzen, um Sicherheitsvorkehrungen zu umgehen und seine Rechte auf "root" zu erweitern.

08

auch bekannt als (4)

Weitere Namen und Kennungen dieser Entität.

09

quellen

Welche Quellen diesen Datensatz belegen und wann.

10

Referenzen (41)

Externe Belege — Patches, Meldungen, Analysen.

scry

Angreifer nutzen Schwachstellen wie diese gegen im Internet exponierte Dienste aus. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.

Kostenloser Scan