CVE-2025-32454
highPriorität · verfolgen · 0EPSS 0.002 · 8. PerzentilDEEUNLRUUSEPSS · bewertet 2026-10-27
A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.14), Teamcenter Visualization V2312 (All versions < V2312.0010), Teamcenter Visualization V2406 (All versions < V2406.0008), Teamcenter Visualization V2412 (All versions < V2412.0004), Tecnomatix Plant Simulation V2404 (All versions < V2404.0013). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process.
Behebungen
Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.
Ein Hersteller-Fix ist verfügbar.
- BehobenTecnomatix Plant Simulation V2404siemens_psirt
Update to V2404.0013 or later version
https://support.sw.siemens.com/product/297028302/ - BehobenTeamcenter Visualization V14.3siemens_psirt
Update to V14.3.0.14 or later version
https://support.sw.siemens.com/product/229029598/ - BehobenTeamcenter Visualization V2312siemens_psirt
Update to V2312.0010 or later version
https://support.sw.siemens.com/product/229029598/ - BehobenTeamcenter Visualization V2406siemens_psirt
Update to V2406.0008 or later version
https://support.sw.siemens.com/product/229029598/ - BehobenTeamcenter Visualization V2412siemens_psirt
Update to V2412.0004 or later version
https://support.sw.siemens.com/product/229029598/ - BehobenTeamcenter Visualization V14.3cisa_csaf_ot
Update to V14.3.0.14 or later version
https://support.sw.siemens.com/product/229029598/ - BehobenTeamcenter Visualization V2312cisa_csaf_ot
Update to V2312.0010 or later version
https://support.sw.siemens.com/product/229029598/ - BehobenTeamcenter Visualization V2406cisa_csaf_ot
Update to V2406.0008 or later version
https://support.sw.siemens.com/product/229029598/ - BehobenTeamcenter Visualization V2412cisa_csaf_ot
Update to V2412.0004 or later version
https://support.sw.siemens.com/product/229029598/ - BehobenTecnomatix Plant Simulation V2404cisa_csaf_ot
Update to V2404.0013 or later version
https://support.sw.siemens.com/product/297028302/ - MitigationTecnomatix Plant Simulation V2404siemens_psirt
Do not open untrusted WRL files in affected applications
- MitigationTeamcenter Visualization V14.3siemens_psirt
Do not open untrusted WRL files in affected applications
- MitigationTeamcenter Visualization V2312siemens_psirt
Do not open untrusted WRL files in affected applications
- MitigationTeamcenter Visualization V2406siemens_psirt
Do not open untrusted WRL files in affected applications
- MitigationTeamcenter Visualization V2412siemens_psirt
Do not open untrusted WRL files in affected applications
- MitigationTeamcenter Visualization V14.3cisa_csaf_ot
Do not open untrusted WRL files in affected applications
- MitigationTeamcenter Visualization V2312cisa_csaf_ot
Do not open untrusted WRL files in affected applications
- MitigationTeamcenter Visualization V2406cisa_csaf_ot
Do not open untrusted WRL files in affected applications
- MitigationTeamcenter Visualization V2412cisa_csaf_ot
Do not open untrusted WRL files in affected applications
- MitigationTecnomatix Plant Simulation V2404cisa_csaf_ot
Do not open untrusted WRL files in affected applications
cvss
Technischer Schweregrad, 0–10. Eine Zeile je Quelle.
Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen⚠ Quellen uneinig · medium–high · 4.4–7.8
SSVC
Eine Handlungsentscheidung — aus Ausnutzung und Auswirkung.
schwächen
Die CWE-Schwächeklassen, zu denen dies gehört.
betroffene Produkte (666)
Betroffene Produkte und Versionsbereiche.
Advisories (6)
Hersteller- und Ökosystem-Meldungen dazu.
- NCSC-2025-0160Kwetsbaarheden verholpen in Siemens productenNL2025-05-14csaf · ncsc_nlNL
Siemens heeft kwetsbaarheden verholpen in diverse producten als Apogee, BacNet ATEC, Desigo CC, Intralog, OZW, Polarion, RUGGEDCOM, SICAM, SIMATIC, SIPROTEC, SIRIUS, Teamcenter en Versicharge
- NCSC-2025-0187Kwetsbaarheden verholpen in Siemens productenNL2025-06-10csaf · ncsc_nlNL
Siemens heeft kwetsbaarheden verholpen in diverse producten als RUGGEDCOM, SCALANCE, SIMATIC en Tecnomatix
- SSA-486186SSA-486186: Out of Bounds Read Vulnerability in Tecnomatix Plant Simulation Before 24042025-06-10csaf · siemens_psirtDE
Siemens Tecnomatix Plant Simulation contains a out-of-bound read vulnerability that could be triggered when the application reads files in WRL format. If a user is tricked to open a malicious file with any of the affected products, this could lead the application to crash or potentially lead to arbitrary code execution. Siemens has released new versions for the affected products and recommends to update to the latest versions.
- SSA-542540SSA-542540: Out of Bounds Read Vulnerability in Teamcenter Visualization2025-05-13csaf · siemens_psirtDE
Siemens Teamcenter Visualization contains a out-of-bound read vulnerability that could be triggered when the application reads files in WRL format. If a user is tricked to open a malicious file with any of the affected products, this could lead the application to crash or potentially lead to arbitrary code execution. Siemens has released new versions for the affected products and recommends to update to the latest versions.
- ICSA-25-135-06Siemens Teamcenter Visualization2025-05-13icsa · cisa_csaf_otUS
Siemens Teamcenter Visualization contains a out-of-bound read vulnerability that could be triggered when the application reads files in WRL format. If a user is tricked to open a malicious file with any of the affected products, this could lead the application to crash or potentially lead to arbitrary code execution. Siemens has released new versions for the affected products and recommends to update to the latest versions.
- ICSA-25-162-01Siemens Tecnomatix Plant Simulation2025-06-10icsa · cisa_csaf_otUS
Siemens Tecnomatix Plant Simulation contains a out-of-bound read vulnerability that could be triggered when the application reads files in WRL format. If a user is tricked to open a malicious file with any of the affected products, this could lead the application to crash or potentially lead to arbitrary code execution. Siemens has released new versions for the affected products and recommends to update to the latest versions.
auch bekannt als (5)
Weitere Namen und Kennungen dieser Entität.
quellen
Welche Quellen diesen Datensatz belegen und wann.
Referenzen (8)
Externe Belege — Patches, Meldungen, Analysen.
- https://access.redhat.com/security/cve/cve-2025-32454cnnvd
- https://cert-portal.siemens.com/productcert/html/ssa-486186.htmlcnnvd
- https://cert-portal.siemens.com/productcert/html/ssa-542540.htmlcnnvd
- https://support.sw.siemens.com/product/229029598/Patchcnnvd
- https://cert-portal.siemens.com/productcert/html/ssa-486186.htmlenisa_euvd
- https://cert-portal.siemens.com/productcert/html/ssa-542540.htmlenisa_euvd
- https://cert-portal.siemens.com/productcert/html/ssa-486186.htmlVendor Advisorynvd
- https://cert-portal.siemens.com/productcert/html/ssa-542540.htmlVendor Advisorynvd
Angreifer nutzen Schwachstellen wie diese gegen im Internet exponierte Dienste aus. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.
Kostenloser Scan