CVE-2025-30280

mediumPriorität · verfolgen · 0EPSS 0.005 · 40. PerzentilDEEUNLRUUS
grimoire priorityP3 · Track
Exploitable?
—
no known exploitation
Likely / severe?
0.46% (40th) EPSS
CVSS 5.3 · medium
Is it mine?
124 products
Prüfe deine Angriffsfläche
Who says so?
6 sources
cnnvd · enisa_euvd · fstec_bdu · cisa_csaf_ot

EPSS · bewertet 2026-10-27

A vulnerability has been identified in Mendix Runtime V10 (All versions < V10.21.0), Mendix Runtime V10.12 (All versions < V10.12.16), Mendix Runtime V10.18 (All versions < V10.18.5), Mendix Runtime V10.6 (All versions < V10.6.22), Mendix Runtime V8 (All versions < V8.18.35), Mendix Runtime V9 (All versions < V9.24.34). Affected applications allow for entity enumeration due to distinguishable responses in certain client actions. This could allow an unauthenticated remote attacker to list all valid entities and attribute names of a Mendix Runtime-based application.

01

Behebungen

Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.

Ein Hersteller-Fix ist verfügbar.

02

cvss

Technischer Schweregrad, 0–10. Eine Zeile je Quelle.

6.9
010

Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen⚠ Quellen uneinig · low–medium · 2.7–6.9

v3.15.3mediumCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:Nsecondary · NCSC-NL NL
v3.15.3mediumAV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:Nsecondary · FSTEC (BDU) RU
v3.15.3mediumCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:Nsecondary · productcert@siemens.com DEAusnutzbarkeit 3.9 · Auswirkung 1.4
v3.15.3mediumCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:Nsecondary · Siemens ProductCERT DE
v3.15.3mediumCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:Nsecondary · CISA US
v4.06.9mediumCVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:Nsecondary · ENISA EU
v4.06.9mediumCVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:Xsecondary · productcert@siemens.com DE
v4.02.7lowCVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:U/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:Xsecondary · CVSS-BT (t0sche)
03

SSVC

Eine Handlungsentscheidung — aus Ausnutzung und Auswirkung.

Exploitation: none · Automatable: yes · Technical Impact: partialcoordinatorcisa_ssvcUS
04

schwächen

Die CWE-Schwächeklassen, zu denen dies gehört.

05

betroffene Produkte (124)

Betroffene Produkte und Versionsbereiche.

06

Advisories (3)

Hersteller- und Ökosystem-Meldungen dazu.

  • NCSC-2025-0106Kwetsbaarheden verholpen in Siemens productenNL2025-04-08csaf · ncsc_nlNL

    Siemens heeft kwetsbaarheden verholpen in diverse producten als Industrial Edge Devices, Mendix, SENTRON, SIDIS, SIMATIC, SIPLUS,Insights Hub Private Cloud, Siemens License Server en Solid Edge.

  • SSA-874353SSA-874353: Entity Enumeration Vulnerability in Mendix Runtime2025-04-08csaf · siemens_psirtDE

    Mendix Runtime allows for entity enumeration due to distinguishable responses in certain client actions. This could allow an unauthenticated remote attacker to list all valid entities and attribute names of a Mendix Runtime-based application. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends countermeasures for products where fixes are not, or not yet available.

  • ICSA-25-105-01Siemens Mendix Runtime2025-04-08icsa · cisa_csaf_otUS

    Mendix Runtime allows for entity enumeration due to distinguishable responses in certain client actions. This could allow an unauthenticated remote attacker to list all valid entities and attribute names of a Mendix Runtime-based application. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends countermeasures for products where fixes are not, or not yet available.

07

auch bekannt als (5)

Weitere Namen und Kennungen dieser Entität.

08

quellen

Welche Quellen diesen Datensatz belegen und wann.

09

Referenzen (5)

Externe Belege — Patches, Meldungen, Analysen.

scry

Angreifer nutzen Schwachstellen wie diese gegen im Internet exponierte Dienste aus. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.

Kostenloser Scan