CVE-2025-30163
mediumPriorität · verfolgen · 19OT-Risiko · erhöhtEPSS 0.002 · 11. PerzentilEUUSEPSS · bewertet 2026-10-27
Cilium is a networking, observability, and security solution with an eBPF-based dataplane. Node based network policies (`fromNodes` and `toNodes`) will incorrectly permit traffic to/from non-node endpoints that share the labels specified in `fromNodes` and `toNodes` sections of network policies. Node based network policy is disabled by default in Cilium. This issue affects: Cilium v1.16 between v1.16.0 and v1.16.7 inclusive and v1.17 between v1.17.0 and v1.17.1 inclusive. This issue is fixed in Cilium v1.16.8 and v1.17.2. Users can work around this issue by ensuring that the labels used in `fromNodes` and `toNodes` fields are used exclusively by nodes and not by other endpoints.
cvss
Technischer Schweregrad, 0–10. Eine Zeile je Quelle.
Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen⚠ Quellen uneinig · low–medium · 3.4–4.7
SSVC
Eine Handlungsentscheidung — aus Ausnutzung und Auswirkung.
schwächen
Die CWE-Schwächeklassen, zu denen dies gehört.
betroffene Produkte (9)
Betroffene Produkte und Versionsbereiche.
Advisories (5)
Hersteller- und Ökosystem-Meldungen dazu.
- GHSA-c6pf-2v8j-96mcCilium node based network policies may incorrectly allow workload traffic2025-03-24ghsa · osvUS
### Impact [Node based network policies](https://docs.cilium.io/en/stable/security/policy/language/#node-based) (`fromNodes` and `toNodes`) will incorrectly permit traffic to/from non-node endpoints that share the labels specified in `fromNodes` and `toNodes` sections of network policies. Node based network policy is disabled by default in Cilium. ### Patches This issue was fixed by https://github.com/cilium/cilium/pull/36657. This issue affects: - Cilium v1.16 between v1.16.0 and v1.16.7 inclusive - Cilium v1.17 between v1.17.0 and v1.17.1 inclusive This issue is fixed in: - Cilium v1.16.8 - Cilium v1.17.2 ### Workarounds Users can work around this issue by ensuring that the labels used in `fromNodes` and `toNodes` fields are used exclusively by nodes and not by other endpoints. ### Acknowledgements The Cilium community has worked together with members of Isovalent to prepare these mitigations. Special thanks to @oblazek for reporting and fixing this issue. ### For more information If you think you have found a vulnerability affecting Cilium, we strongly encourage you to report it to our security mailing list at [security@cilium.io](mailto:security@cilium.io). This is a private mailing list for the Cilium security team, and your report will be treated as top priority. Please also address any comments or questions on this advisory to the same mailing list.
- BIT-cilium-2025-30163Node based network policies may incorrectly allow workload traffic2025-03-26vendor · osvUS
Cilium is a networking, observability, and security solution with an eBPF-based dataplane. Node based network policies (`fromNodes` and `toNodes`) will incorrectly permit traffic to/from non-node endpoints that share the labels specified in `fromNodes` and `toNodes` sections of network policies. Node based network policy is disabled by default in Cilium. This issue affects: Cilium v1.16 between v1.16.0 and v1.16.7 inclusive and v1.17 between v1.17.0 and v1.17.1 inclusive. This issue is fixed in Cilium v1.16.8 and v1.17.2. Users can work around this issue by ensuring that the labels used in `fromNodes` and `toNodes` fields are used exclusively by nodes and not by other endpoints.
- BIT-cilium-operator-2025-30163Node based network policies may incorrectly allow workload traffic2025-03-26vendor · osvUS
Cilium is a networking, observability, and security solution with an eBPF-based dataplane. Node based network policies (`fromNodes` and `toNodes`) will incorrectly permit traffic to/from non-node endpoints that share the labels specified in `fromNodes` and `toNodes` sections of network policies. Node based network policy is disabled by default in Cilium. This issue affects: Cilium v1.16 between v1.16.0 and v1.16.7 inclusive and v1.17 between v1.17.0 and v1.17.1 inclusive. This issue is fixed in Cilium v1.16.8 and v1.17.2. Users can work around this issue by ensuring that the labels used in `fromNodes` and `toNodes` fields are used exclusively by nodes and not by other endpoints.
- BIT-hubble-relay-2025-30163Node based network policies may incorrectly allow workload traffic2025-03-26vendor · osvUS
Cilium is a networking, observability, and security solution with an eBPF-based dataplane. Node based network policies (`fromNodes` and `toNodes`) will incorrectly permit traffic to/from non-node endpoints that share the labels specified in `fromNodes` and `toNodes` sections of network policies. Node based network policy is disabled by default in Cilium. This issue affects: Cilium v1.16 between v1.16.0 and v1.16.7 inclusive and v1.17 between v1.17.0 and v1.17.1 inclusive. This issue is fixed in Cilium v1.16.8 and v1.17.2. Users can work around this issue by ensuring that the labels used in `fromNodes` and `toNodes` fields are used exclusively by nodes and not by other endpoints.
- GO-2025-3561Cilium node based network policies may incorrectly allow workload traffic in github.com/cilium/cilium2025-03-25vendor · osvUS
Cilium node based network policies may incorrectly allow workload traffic in github.com/cilium/cilium
auch bekannt als (8)
Weitere Namen und Kennungen dieser Entität.
- CNNVD-202503-2809cnnvd
- EUVD-2025-8006enisa_euvd
- GHSA-c6pf-2v8j-96mcenisa_euvd
- BIT-cilium-2025-30163osv
- BIT-cilium-operator-2025-30163osv
- BIT-hubble-relay-2025-30163osv
- GHSA-c6pf-2v8j-96mcosv
- GO-2025-3561osv
quellen
Welche Quellen diesen Datensatz belegen und wann.
Referenzen (9)
Externe Belege — Patches, Meldungen, Analysen.
- https://docs.cilium.io/en/stable/security/policy/language/#node-basedcnnvd
- https://github.com/cilium/cilium/pull/36657cnnvd
- https://github.com/cilium/cilium/security/advisories/GHSA-c6pf-2v8j-96mccnnvd
- https://docs.cilium.io/en/stable/security/policy/language/#node-basedenisa_euvd
- https://github.com/cilium/cilium/pull/36657enisa_euvd
- https://github.com/cilium/cilium/security/advisories/GHSA-c6pf-2v8j-96mcenisa_euvd
- https://docs.cilium.io/en/stable/security/policy/language/#node-basedProductnvd
- https://github.com/cilium/cilium/pull/36657Patchnvd
Angreifer nutzen Schwachstellen wie diese gegen im Internet exponierte Dienste aus. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.
Kostenloser Scan