CVE-2025-30051

mediumPriorität · verfolgen · 0EPSS 0.001 · 1. Perzentil
grimoire priorityP3 · Track
Exploitable?
—
no known exploitation
Likely / severe?
0.10% (1st) EPSS
CVSS 6.8 · medium
Is it mine?
0 products
Prüfe deine Angriffsfläche
Who says so?
— sources

EPSS · bewertet 2026-10-26

The CGM CLININET application stores the production database login and password, as well as RabbitMQ broker credentials, in the SysIO.pl configuration file. Insecure file permissions make this file readable by any local account.  This issue was fixed in version 2026.MS3

01

cvss

Technischer Schweregrad, 0–10. Eine Zeile je Quelle.

6.8
010

Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen

v4.06.8mediumCVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:Xsecondary · cvd@cert.pl
v4.04.3mediumCVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:U/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:Xsecondary · CVSS-BT (t0sche)
02

schwächen

Die CWE-Schwächeklassen, zu denen dies gehört.

03

betroffene Produkte

Betroffene Produkte und Versionsbereiche.

Keine betroffenen Produkte erfasst.

04

quellen

Welche Quellen diesen Datensatz belegen und wann.

veröffentlicht 2026-10-23geändert 2026-10-23
06

Referenzen (2) nvd

Externe Belege — Patches, Meldungen, Analysen.

scry

Angreifer nutzen Schwachstellen wie diese gegen im Internet exponierte Dienste aus. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.

Kostenloser Scan