CVE-2025-26495

highPriorität · verfolgen · 0OT-Risiko · erhöhtEPSS 0.003 · 27. PerzentilDEEUUS
grimoire priorityP2 · Scheduled
Exploitable?
—
no known exploitation
Likely / severe?
0.34% (27th) EPSS
CVSS 7.5 · high
Is it mine?
13 products
Prüfe deine Angriffsfläche
Who says so?
4 sources
cnnvd · enisa_euvd · nvd · siemens_psirt

EPSS · bewertet 2026-10-27

Cleartext Storage of Sensitive Information vulnerability in Salesforce Tableau Server can record the Personal Access Token (PAT) into logging repositories.This issue affects Tableau Server: before 2022.1.3, before 2021.4.8, before 2021.3.13, before 2021.2.14, before 2021.1.16, before 2020.4.19.

01

Behebungen

Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.

Ein Hersteller-Fix ist verfügbar.

  • BehobenOpcenter Intelligencesiemens_psirt

    Update to V2501 or later version and install the latest available version of Tableau Server as described in https://support.sw.siemens.com/knowledge-base/PL8822108

02

cvss

Technischer Schweregrad, 0–10. Eine Zeile je Quelle.

7.5
010

Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen⚠ Quellen uneinig · medium–high · 4.9–7.5

v3.17.5highCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:Nsecondary · ENISA EU
v3.17.5highCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:NsecondaryAusnutzbarkeit 3.9 · Auswirkung 3.6
v3.14.9mediumCVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:Nsecondary · Siemens ProductCERT DE
v3.16.9mediumCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N/E:Usecondary · CVSS-BT (t0sche)
03

SSVC

Eine Handlungsentscheidung — aus Ausnutzung und Auswirkung.

Exploitation: none · Automatable: yes · Technical Impact: partialcoordinatorcisa_ssvcUS
04

schwächen

Die CWE-Schwächeklassen, zu denen dies gehört.

05

betroffene Produkte (13)

Betroffene Produkte und Versionsbereiche.

06

Advisories (1)

Hersteller- und Ökosystem-Meldungen dazu.

  • SSA-246355SSA-246355: Multiple Vulnerabilities in Tableau Server Component of Opcenter Intelligence2025-02-11csaf · siemens_psirtDE

    The Tableau Server component in Opcenter Intelligence contains multiple vulnerabilities as described below. Siemens has released a new version for Opcenter Intelligence and recommends to update to the latest version and to install the latest available version of Tableau Server as described in https://support.sw.siemens.com/knowledge-base/PL8822108.

07

auch bekannt als (3)

Weitere Namen und Kennungen dieser Entität.

08

quellen

Welche Quellen diesen Datensatz belegen und wann.

veröffentlicht 2025-02-11geändert 2026-06-17
09

Referenzen (3)

Externe Belege — Patches, Meldungen, Analysen.

scry

Angreifer nutzen Schwachstellen wie diese gegen im Internet exponierte Dienste aus. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.

Kostenloser Scan