CVE-2025-23384

lowPriorität · verfolgen · 0EPSS 0.003 · 20. PerzentilDEEUNLRUUS
grimoire priorityP3 · Track
Exploitable?
—
no known exploitation
Likely / severe?
0.28% (20th) EPSS
CVSS 3.7 · low
Is it mine?
261 products
Prüfe deine Angriffsfläche
Who says so?
6 sources
cnnvd · enisa_euvd · fstec_bdu · cisa_csaf_ot

EPSS · bewertet 2026-10-27

A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) (All versions < V8.2.1), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2) (All versions < V8.2.1), SCALANCE M804PB (6GK5804-0AP00-2AA2) (All versions < V8.2.1), SCALANCE M812-1 ADSL-Router family (All versions < V8.2.1), SCALANCE M816-1 ADSL-Router family (All versions < V8.2.1), SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2) (All versions < V8.2.1), SCALANCE M874-2 (6GK5874-2AA00-2AA2) (All versions < V8.2.1), SCALANCE M874-3 (6GK5874-3AA00-2AA2) (All versions < V8.2.1), SCALANCE M874-3 3G-Router (CN) (6GK5874-3AA00-2FA2) (All versions < V8.2.1), SCALANCE M876-3 (6GK5876-3AA02-2BA2) (All versions < V8.2.1), SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2) (All versions < V8.2.1), SCALANCE M876-4 (6GK5876-4AA10-2BA2) (All versions < V8.2.1), SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2) (All versions < V8.2.1), SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2) (All versions < V8.2.1), SCALANCE MUB852-1 (A1) (6GK5852-1EA10-1AA1) (All versions < V8.2.1), SCALANCE MUB852-1 (B1) (6GK5852-1EA10-1BA1) (All versions < V8.2.1), SCALANCE MUM853-1 (A1) (6GK5853-2EA10-2AA1) (All versions < V8.2.1), SCALANCE MUM853-1 (B1) (6GK5853-2EA10-2BA1) (All versions < V8.2.1), SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1) (All versions < V8.2.1), SCALANCE MUM856-1 (A1) (6GK5856-2EA10-3AA1) (All versions < V8.2.1), SCALANCE MUM856-1 (B1) (6GK5856-2EA10-3BA1) (All versions < V8.2.1), SCALANCE MUM856-1 (CN) (6GK5856-2EA00-3FA1) (All versions < V8.2.1), SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1) (All versions < V8.2.1), SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1) (All versions < V8.2.1), SCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2) (All versions < V8.2.1), SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2) (All versions < V8.2.1), SCALANCE SC622-2C (6GK5622-2GS00-2AC2) (All versions < V3.2), SCALANCE SC626-2C (6GK5626-2GS00-2AC2) (All versions < V3.2), SCALANCE SC632-2C (6GK5632-2GS00-2AC2) (All versions < V3.2), SCALANCE SC636-2C (6GK5636-2GS00-2AC2) (All versions < V3.2), SCALANCE SC642-2C (6GK5642-2GS00-2AC2) (All versions < V3.2), SCALANCE SC646-2C (6GK5646-2GS00-2AC2) (All versions < V3.2). Affected devices improperly validate usernames during OpenVPN authentication. This could allow an attacker to get partial invalid usernames accepted by the server.

01

Behebungen

Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.

Ein Hersteller-Fix ist verfügbar.

02

cvss

Technischer Schweregrad, 0–10. Eine Zeile je Quelle.

6.3
010

Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen⚠ Quellen uneinig · low–medium · 1.7–6.3

v3.13.7lowCVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:L/A:N/E:P/RL:O/RC:Csecondary · NCSC-NL NL
v3.13.7lowAV:N/AC:H/PR:N/UI:N/S:U/C:N/I:L/A:Nsecondary · FSTEC (BDU) RU
v3.13.7lowCVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:L/A:Nsecondary · productcert@siemens.com DEAusnutzbarkeit 2.2 · Auswirkung 1.4
v3.13.7lowCVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:L/A:N/E:P/RL:O/RC:Csecondary · Siemens ProductCERT DE
v3.13.7lowCVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:L/A:N/E:P/RL:O/RC:Csecondary · CISA US
v4.06.3mediumCVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:Nsecondary · ENISA EU
v4.06.3mediumCVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:Xsecondary · productcert@siemens.com DE
v4.01.7lowCVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N/E:U/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:Xsecondary · CVSS-BT (t0sche)
03

SSVC

Eine Handlungsentscheidung — aus Ausnutzung und Auswirkung.

Trackcoordinatorcisa_ssvcUS
04

schwächen

Die CWE-Schwächeklassen, zu denen dies gehört.

05

betroffene Produkte (261)

Betroffene Produkte und Versionsbereiche.

06

Advisories (3)

Hersteller- und Ökosystem-Meldungen dazu.

  • NCSC-2025-0077Kwetsbaarheden verholpen in Siemens productenNL2025-03-11csaf · ncsc_nlNL

    Siemens heeft kwetsbaarheden verholpen in diverse producten als SCALANCE, SIMATIC, SINAMICS, SINEMA, SiPass, Teamcenter en Tecnomatix.

  • SSA-280834SSA-280834: Improper OpenVPN Credential Validation Vulnerability in SCALANCE M-800 and SC-600 Families2025-03-11csaf · siemens_psirtDE

    SCALANCE M-800 and SC-600 families are affected by improper input validation in the OpenVPN authentication. Siemens has released new versions for the affected products and recommends to update to the latest versions.

  • ICSA-25-072-07Siemens SCALANCE M-800 and SC-600 Families2025-03-11icsa · cisa_csaf_otUS

    SCALANCE M-800 and SC-600 families are affected by improper input validation in the OpenVPN authentication. Siemens has released new versions for the affected products and recommends to update to the latest versions.

07

auch bekannt als (5)

Weitere Namen und Kennungen dieser Entität.

08

quellen

Welche Quellen diesen Datensatz belegen und wann.

09

Referenzen (5)

Externe Belege — Patches, Meldungen, Analysen.

scry

Angreifer nutzen Schwachstellen wie diese gegen im Internet exponierte Dienste aus. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.

Kostenloser Scan