CVE-2025-11739

highPriorität · verfolgen · 31EPSS 0.002 · 9. PerzentilEURUUS
grimoire priorityP2 · Scheduled
Exploitable?
—
no known exploitation
Likely / severe?
0.19% (9th) EPSS
CVSS 7.8 · high
Is it mine?
33 products
Prüfe deine Angriffsfläche
Who says so?
4 sources
cnnvd · enisa_euvd · fstec_bdu · cisa_csaf_ot

EPSS · bewertet 2026-10-27

CWE‑502: Deserialization of Untrusted Data vulnerability exists that could cause arbitrary code execution with administrative privileges when a locally authenticated attacker sends a crafted data stream, triggering unsafe deserialization.

01

Behebungen

Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.

Ein Hersteller-Fix ist verfügbar.

  • BehobenEcoStruxure Power Monitoring Expert (PME)cisa_csaf_ot

    Customers should upgrade to EcoStruxure Power Monitoring Expert (PME) 2023 R2. Once upgraded, Hotfix_282807 - for 2023R2 is available for EcoStruxure Power Monitoring Expert (PME) that includes a fix for this vulnerability. Contact Schneider Electric’s Customer Care Center for assistance.

  • BehobenEcoStruxure Power Operation (EPO) Advanced Reporting and Dashboards Modulecisa_csaf_ot

    Customers should upgrade to EcoStruxure Power Monitoring Expert (PME) 2023 R2. Once upgraded, Hotfix_282807 - for 2023R2 is available for EcoStruxure Power Monitoring Expert (PME) that includes a fix for this vulnerability. Contact Schneider Electric’s Customer Care Center for assistance.

  • Kein Fix geplantEcoStruxure Power Monitoring Expert (PME) 2022cisa_csaf_ot

    EcoStruxure Power Monitoring Expert (PME) 2022 version has reached its end of life and is no longer supported. • Ensure your deployment of PME has followed the cybersecurity hardening guidelines provided with the product. https://product-help.schneider-electric.com/EcoStruxure/Power-Monitoring-Expert-2024/content/2_planning/cybersecurity/cyber-planningrecactions.htm • Ensure PME is running in an isolated network • Deploy and configure the Windows firewall to limit access to appropriate network segments• Enforce complex password policies.o Review Server Access Permissions o Conduct an audit of all Windows-authenticated users who currently have access to PME. Repeat this audit of your system periodically. o Identify all accounts with access rights, especially those with elevated privileges or remote access. o Limit access to essential users only.o Revoke access for any user accounts that are not critical for system functionality or daily operations.o Apply the principle of least privilege to ensure users have only the access necessary for their role(s). Customers should also consider upgrading to the latest product offering EcoStruxure Power Monitoring Expert (PME) 2024 R3 to resolve this issue.

    https://product-help.schneider-electric.com/EcoStruxure/Power-Monitoring-Expert-2024/content/2_planning/cybersecurity/cyber-planningrecactions.htm
  • Kein Fix geplantEcoStruxure Power Operation (EPO) 2022 Advanced Reporting and Dashboards Modulecisa_csaf_ot

    EcoStruxure Power Operation (EPO) 2022 version and EcoStruxure Power Monitoring Expert (PME) 2022 has reached its end of life and is no longer supported. • Ensure your deployment of PME has followed the cybersecurity hardening guidelines provided with the product. https://product-help.schneider-electric.com/EcoStruxure/Power-Monitoring-Expert-2024/content/2_planning/cybersecurity/cyber-planningrecactions.htm • Ensure PME is running in an isolated network • Deploy and configure the Windows firewall to limit access to appropriate network segments• Enforce complex password policies.o Review Server Access Permissions o Conduct an audit of all Windows-authenticated users who currently have access to PME. Repeat this audit of your system periodically. o Identify all accounts with access rights, especially those with elevated privileges or remote access. o Limit access to essential users only.o Revoke access for any user accounts that are not critical for system functionality or daily operations.o Apply the principle of least privilege to ensure users have only the access necessary for their role(s). Customers should also consider upgrading to the latest product offering EcoStruxure Power Monitoring Expert (PME) 2024 R3 to resolve this issue.

    https://product-help.schneider-electric.com/EcoStruxure/Power-Monitoring-Expert-2024/content/2_planning/cybersecurity/cyber-planningrecactions.htm
02

cvss

Technischer Schweregrad, 0–10. Eine Zeile je Quelle.

8.5
010

Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen⚠ Quellen uneinig · medium–high · 5.9–8.5

v3.17.8highCVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:Hprimary · NVD / NIST USAusnutzbarkeit 1.8 · Auswirkung 5.9
v3.17.8highCVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:Hsecondary · CISA US
v3.17.8highAV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:Hsecondary · FSTEC (BDU) RU
v4.08.5highCVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:Nsecondary · ENISA EU
v4.08.5highCVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:Xsecondary · cybersecurity@se.com
v4.05.9mediumCVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:U/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:Xsecondary · CVSS-BT (t0sche)
03

SSVC

Eine Handlungsentscheidung — aus Ausnutzung und Auswirkung.

Exploitation: none · Automatable: no · Technical Impact: totalcoordinatorcisa_ssvcUS
04

schwächen

Die CWE-Schwächeklassen, zu denen dies gehört.

05

betroffene Produkte (33)

Betroffene Produkte und Versionsbereiche.

20 von 33 angezeigt
06

Advisories (1)

Hersteller- und Ökosystem-Meldungen dazu.

  • ICSA-26-078-04Schneider Electric EcoStruxure PME and EPO2026-03-10icsa · cisa_csaf_otUS

    Schneider Electric is aware of a vulnerability in its EcoStruxure Power Monitoring Expert (PME) and EcoStruxure Power Operation (EPO) products. EcoStruxure Power Monitoring Expert (PME) is an on-premises software used to help power critical and energy-intensive facilities maximize uptime and operational efficiency. EcoStruxure Power Operation (EPO) are on-premises software offers that provides a single platform to monitor and control medium and lower power systems.Failure to apply the fix provided below may risk local arbitrary code execution, which could result in the local system being compromised, a disruption of operations, and/or unauthorized administrative control of the system.

07

auch bekannt als (4)

Weitere Namen und Kennungen dieser Entität.

08

quellen

Welche Quellen diesen Datensatz belegen und wann.

veröffentlicht 2026-03-10geändert 2026-06-24
09

Referenzen (4)

Externe Belege — Patches, Meldungen, Analysen.

scry

Angreifer nutzen Schwachstellen wie diese gegen im Internet exponierte Dienste aus. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.

Kostenloser Scan