CVE-2024-6657
mediumPriorität · verfolgen · 0EPSS 0.002 · 9. PerzentilDEEUNLRUUSEPSS · bewertet 2026-10-27
A denial of service may be caused to a single peripheral device in a BLE network when multiple central devices continuously connect and disconnect to the peripheral. A hard reset is required to recover the peripheral device.
cvss
Technischer Schweregrad, 0–10. Eine Zeile je Quelle.
Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen
SSVC
Eine Handlungsentscheidung — aus Ausnutzung und Auswirkung.
schwächen
Die CWE-Schwächeklassen, zu denen dies gehört.
betroffene Produkte (12)
Betroffene Produkte und Versionsbereiche.
- sentron_powercenter_1000__7kn1110-0mc00_alle Versionenncsc_nlNLcpe:2.3:a:siemens:sentron_powercenter_1000__7kn1110-0mc00_:*:*:*:*:*:*:*:*
- sentron_powercenter_1100__7kn1111-0mc00_alle Versionenncsc_nlNLcpe:2.3:a:siemens:sentron_powercenter_1100__7kn1111-0mc00_:*:*:*:*:*:*:*:*
Advisories (3)
Hersteller- und Ökosystem-Meldungen dazu.
- NCSC-2024-0473Kwetsbaarheden verholpen in Siemens productenNL2024-12-10csaf · ncsc_nlNL
Siemens heeft kwetsbaarheden verholpen in diverse producten als COMOS, RUGGEDCOM, SENTRON, SICAM, SIMATIC en TeamCenter.
- SSA-620799SSA-620799: Denial of Service Vulnerability During BLE Pairing in SENTRON Powercenter 1000/11002024-12-10csaf · siemens_psirtDE
SENTRON Powercenter devices are not affected by a denial of service vulnerability that can be triggered during BLE (Bluetooth Low Energy) pairing. Note: Unlike stated in the initial version of this security advisory from 2024-12-10, detailed analysis has shown that SENTRON Powercenter devices are not affected by this vulnerability.
- ICSA-24-347-10Siemens SENTRON Powercenter 10002024-12-10icsa · cisa_csaf_otUS
SENTRON Powercenter devices are not affected by a denial of service vulnerability that can be triggered during BLE (Bluetooth Low Energy) pairing. Note: Unlike stated in the initial version of this security advisory from 2024-12-10, detailed analysis has shown that SENTRON Powercenter devices are not affected by this vulnerability.
auch bekannt als (6)
Weitere Namen und Kennungen dieser Entität.
quellen
Welche Quellen diesen Datensatz belegen und wann.
Referenzen (5)
Externe Belege — Patches, Meldungen, Analysen.
- https://cxsecurity.com/cveshow/CVE-2024-6657/cnnvd
- https://docs.silabs.com/bluetooth/latest/bluetooth-stack-overview/Patchcnnvd
- https://siliconlabs.lightning.force.com/sfc/servlet.shepherd/document/download/069Vm00000E9IIbIAN?operationContext=S1cnnvd
- https://community.silabs.com/068Vm00000FfVNNenisa_euvd
- https://community.silabs.com/068Vm00000FfVNNnvd
Angreifer nutzen Schwachstellen wie diese gegen im Internet exponierte Dienste aus. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.
Kostenloser Scan