CVE-2024-6528

mediumPriorität · verfolgen · 24EPSS 0.003 · 17. PerzentilEURUUS
grimoire priorityP3 · Track
Exploitable?
—
no known exploitation
Likely / severe?
0.26% (17th) EPSS
CVSS 6.1 · medium
Is it mine?
21 products
Prüfe deine Angriffsfläche
Who says so?
5 sources
cnnvd · enisa_euvd · fstec_bdu · cisa_csaf_ot

EPSS · bewertet 2026-10-23

CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause a vulnerability leading to a cross-site scripting condition where attackers can have a victim’s browser run arbitrary JavaScript when they visit a page containing the injected payload.

01

Behebungen

Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.

Ein Hersteller-Fix ist verfügbar.

  • BehobenSchneider Electric Modicon Controllers M258 / LMC058cisa_csaf_ot

    Schneider Electric Modicon Controllers Version prior to v5.2.11.24, Schneider Electric Modicon Controllers M258 / LMC058 All versions , Schneider Electric Modicon Controllers M262 Versions prior to v5.2.8.26, Schneider Electric Modicon Controllers Version prior to v5.2.11.24: Modicon Controller M262 Firmware version 5.2.8.26 delivered with EcoStruxure Machine Expert v2.2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machineexpert-software/ On the engineering workstation, update to v2.2.2 of EcoStruxure Machine Expert. By using Controller Assistant from EcoStruxureTM Machine Expert update Modicon Controller M258/LMC058 and perform reboot .

    https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/
  • BehobenSchneider Electric Modicon Controllers M262cisa_csaf_ot

    Schneider Electric Modicon Controllers M262 Versions prior to v5.2.8.26: Modicon Controller M262 Firmware version 5.2.8.26 delivered with EcoStruxure Machine Expert v2.2.2 includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/ On the engineering workstation, update to v2.2.2 of EcoStruxure Machine Expert. Update Modicon Controller M262 to the latest Firmware and perform reboot

    https://www.se.com/ww/en/product-range/2226-ecostruxure-machine-expert-software/
  • MitigationSchneider Electric Modicon Controllers M241cisa_csaf_ot

    If users choose not to apply the remediation provided above they should immediately apply the following mitigations to reduce the risk of exploit:

  • MitigationSchneider Electric Modicon Controllers M251cisa_csaf_ot

    If users choose not to apply the remediation provided above they should immediately apply the following mitigations to reduce the risk of exploit:

  • MitigationSchneider Electric Modicon Controllers M258 / LMC058cisa_csaf_ot

    If users choose not to apply the remediation provided above they should immediately apply the following mitigations to reduce the risk of exploit:

  • MitigationSchneider Electric Modicon Controllers M262cisa_csaf_ot

    If users choose not to apply the remediation provided above they should immediately apply the following mitigations to reduce the risk of exploit:

02

cvss

Technischer Schweregrad, 0–10. Eine Zeile je Quelle.

6.1
010

Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen

v3.16.1mediumCVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:Nprimary · NVD / NIST USAusnutzbarkeit 2.8 · Auswirkung 2.7
v3.15.4mediumCVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:Nsecondary · CISA US
v3.15.4mediumAV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:Nsecondary · FSTEC (BDU) RU
v3.15.4mediumCVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:Nsecondary · ENISA EU
v3.15.4mediumCVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:Nsecondary · cybersecurity@se.comAusnutzbarkeit 2.3 · Auswirkung 2.7
v3.15.6mediumCVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N/E:Usecondary · CVSS-BT (t0sche)
03

SSVC

Eine Handlungsentscheidung — aus Ausnutzung und Auswirkung.

Trackcoordinatorcisa_ssvcUS
04

schwächen

Die CWE-Schwächeklassen, zu denen dies gehört.

05

betroffene Produkte (21)

Betroffene Produkte und Versionsbereiche.

20 von 21 angezeigt
06

Advisories (1)

Hersteller- und Ökosystem-Meldungen dazu.

  • ICSA-24-354-07Schneider Electric Modicon Controllers (Update A)2024-12-19icsa · cisa_csaf_otUS

    Successful exploitation of this vulnerability could allow an attacker to cause a victim's browser to run arbitrary JavaScript when visiting a page containing injected payload.

07

auch bekannt als (4)

Weitere Namen und Kennungen dieser Entität.

08

quellen

Welche Quellen diesen Datensatz belegen und wann.

veröffentlicht 2024-07-11geändert 2026-06-17
09

Referenzen (4)

Externe Belege — Patches, Meldungen, Analysen.

scry

Angreifer nutzen Schwachstellen wie diese gegen im Internet exponierte Dienste aus. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.

Kostenloser Scan