A vulnerability has been identified in SIMATIC S7-PLCSIM V17 (All versions), SIMATIC S7-PLCSIM V18 (All versions), SIMATIC STEP 7 Safety V17 (All versions < V17 Update 9), SIMATIC STEP 7 Safety V18 (All versions < V18 Update 6), SIMATIC STEP 7 Safety V19 (All versions < V19 Update 4), SIMATIC STEP 7 V17 (All versions < V17 Update 9), SIMATIC STEP 7 V18 (All versions < V18 Update 6), SIMATIC STEP 7 V19 (All versions < V19 Update 4), SIMATIC WinCC Unified PC Runtime V18 (All versions), SIMATIC WinCC Unified PC Runtime V19 (All versions < V19 Update 4), SIMATIC WinCC Unified V17 (All versions < V17 Update 9), SIMATIC WinCC Unified V18 (All versions < V18 Update 6), SIMATIC WinCC Unified V19 (All versions < V19 Update 4), SIMATIC WinCC V17 (All versions < V17 Update 9), SIMATIC WinCC V18 (All versions < V18 Update 6), SIMATIC WinCC V19 (All versions < V19 Update 4), SIMOCODE ES V17 (All versions), SIMOCODE ES V18 (All versions), SIMOCODE ES V19 (All versions), SIMOTION SCOUT TIA V5.4 (All versions), SIMOTION SCOUT TIA V5.5 (All versions), SIMOTION SCOUT TIA V5.6 (All versions < V5.6 SP1 HF7), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SINAMICS Startdrive V19 (All versions), SIRIUS Safety ES V17 (TIA Portal) (All versions), SIRIUS Safety ES V18 (TIA Portal) (All versions), SIRIUS Safety ES V19 (TIA Portal) (All versions), SIRIUS Soft Starter ES V17 (TIA Portal) (All versions), SIRIUS Soft Starter ES V18 (TIA Portal) (All versions), SIRIUS Soft Starter ES V19 (TIA Portal) (All versions), TIA Portal Cloud V17 (All versions), TIA Portal Cloud V18 (All versions), TIA Portal Cloud V19 (All versions < V5.2.1.1). The affected devices do not properly sanitize user-controllable input when parsing user settings. This could allow an attacker to locally execute arbitrary commands in the host operating system with the privileges of the user.
Behebungen
Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.
Ein Hersteller-Fix ist verfügbar.
- BehobenSIMATIC STEP 7 Safety V17siemens_psirt
Update to V17 Update 9 or later version
https://support.industry.siemens.com/cs/ww/en/view/109784441/ - BehobenSIMATIC STEP 7 Safety V18siemens_psirt
Update to V18 Update 6 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817218/ - BehobenSIMATIC STEP 7 Safety V19siemens_psirt
Update to V19 Update 4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109925643/ - BehobenSIMATIC STEP 7 V17siemens_psirt
Update to V17 Update 9 or later version
https://support.industry.siemens.com/cs/ww/en/view/109784441/ - BehobenSIMATIC STEP 7 V18siemens_psirt
Update to V18 Update 6 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817218/ - BehobenSIMATIC STEP 7 V19siemens_psirt
Update to V19 Update 4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109925643/ - BehobenSIMATIC WinCC Unified PC Runtime V19siemens_psirt
Update to V19 Update 4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109925643/ - BehobenSIMATIC WinCC Unified V17siemens_psirt
Update to V17 Update 9 or later version
https://support.industry.siemens.com/cs/ww/en/view/109784441/ - BehobenSIMATIC WinCC Unified V18siemens_psirt
Update to V18 Update 6 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817218/ - BehobenSIMATIC WinCC Unified V19siemens_psirt
Update to V19 Update 4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109925643/ - BehobenSIMATIC WinCC V17siemens_psirt
Update to V17 Update 9 or later version
https://support.industry.siemens.com/cs/ww/en/view/109784441/ - BehobenSIMATIC WinCC V18siemens_psirt
Update to V18 Update 6 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817218/ - BehobenSIMATIC WinCC V19siemens_psirt
Update to V19 Update 4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109925643/ - BehobenSIMOTION SCOUT TIA V5.6siemens_psirt
Update to V5.6 SP1 HF7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109989067/ - BehobenTIA Portal Cloud V19siemens_psirt
TIA Portal Cloud V5.2.1.1 or later version updated TIA Portal to V19 Update 4 or later version
- BehobenSIMATIC STEP 7 Safety V17cisa_csaf_ot
Update to V17 Update 9 or later version
https://support.industry.siemens.com/cs/ww/en/view/109784441/ - BehobenSIMATIC STEP 7 Safety V19cisa_csaf_ot
Update to V19 Update 4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109925643/ - BehobenSIMATIC STEP 7 V17cisa_csaf_ot
Update to V17 Update 9 or later version
https://support.industry.siemens.com/cs/ww/en/view/109784441/ - BehobenSIMATIC STEP 7 V19cisa_csaf_ot
Update to V19 Update 4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109925643/ - BehobenSIMATIC WinCC Unified PC Runtime V19cisa_csaf_ot
Update to V19 Update 4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109925643/ - BehobenSIMATIC WinCC Unified V17cisa_csaf_ot
Update to V17 Update 9 or later version
https://support.industry.siemens.com/cs/ww/en/view/109784441/ - BehobenSIMATIC WinCC Unified V19cisa_csaf_ot
Update to V19 Update 4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109925643/ - BehobenSIMATIC WinCC V17cisa_csaf_ot
Update to V17 Update 9 or later version
https://support.industry.siemens.com/cs/ww/en/view/109784441/ - BehobenSIMATIC WinCC V19cisa_csaf_ot
Update to V19 Update 4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109925643/ - BehobenSIMOTION SCOUT TIA V5.6cisa_csaf_ot
Update to V5.6 SP1 HF7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109989067/ - BehobenTIA Portal Cloud V19cisa_csaf_ot
TIA Portal Cloud V5.2.1.1 or later version updated TIA Portal to V19 Update 4 or later version
- Kein Fix verfügbarSIMATIC WinCC Unified PC Runtime V18siemens_psirt
Currently no fix is available
- Kein Fix verfügbarSIMOCODE ES V17siemens_psirt
Currently no fix is available
- Kein Fix verfügbarSIMOCODE ES V18siemens_psirt
Currently no fix is available
- Kein Fix verfügbarSIMOCODE ES V19siemens_psirt
Currently no fix is available
- Kein Fix verfügbarSIMOTION SCOUT TIA V5.4siemens_psirt
Currently no fix is available
- Kein Fix verfügbarSIMOTION SCOUT TIA V5.5siemens_psirt
Currently no fix is available
- Kein Fix verfügbarSINAMICS Startdrive V17siemens_psirt
Currently no fix is available
- Kein Fix verfügbarSINAMICS Startdrive V18siemens_psirt
Currently no fix is available
- Kein Fix verfügbarSINAMICS Startdrive V19siemens_psirt
Currently no fix is available
- Kein Fix verfügbarSIRIUS Safety ES V17 (TIA Portal)siemens_psirt
Currently no fix is available
- Kein Fix verfügbarSIRIUS Safety ES V18 (TIA Portal)siemens_psirt
Currently no fix is available
- Kein Fix verfügbarSIRIUS Safety ES V19 (TIA Portal)siemens_psirt
Currently no fix is available
- Kein Fix verfügbarSIRIUS Soft Starter ES V17 (TIA Portal)siemens_psirt
Currently no fix is available
- Kein Fix verfügbarSIRIUS Soft Starter ES V18 (TIA Portal)siemens_psirt
Currently no fix is available
- Kein Fix verfügbarSIRIUS Soft Starter ES V19 (TIA Portal)siemens_psirt
Currently no fix is available
- Kein Fix verfügbarTIA Portal Cloud V17siemens_psirt
Currently no fix is available
- Kein Fix verfügbarTIA Portal Cloud V18siemens_psirt
Currently no fix is available
- Kein Fix verfügbarSIMATIC S7-PLCSIM V17cisa_csaf_ot
Currently no fix is available
- Kein Fix verfügbarSIMATIC S7-PLCSIM V18cisa_csaf_ot
Currently no fix is available
- Kein Fix verfügbarSIMATIC STEP 7 Safety V18cisa_csaf_ot
Currently no fix is available
- Kein Fix verfügbarSIMATIC STEP 7 V18cisa_csaf_ot
Currently no fix is available
- Kein Fix verfügbarSIMATIC WinCC Unified PC Runtime V18cisa_csaf_ot
Currently no fix is available
- Kein Fix verfügbarSIMATIC WinCC Unified V18cisa_csaf_ot
Currently no fix is available
- Kein Fix verfügbarSIMATIC WinCC V18cisa_csaf_ot
Currently no fix is available
- Kein Fix verfügbarSIMOCODE ES V17cisa_csaf_ot
Currently no fix is available
- Kein Fix verfügbarSIMOCODE ES V18cisa_csaf_ot
Currently no fix is available
- Kein Fix verfügbarSIMOCODE ES V19cisa_csaf_ot
Currently no fix is available
- Kein Fix verfügbarSIMOTION SCOUT TIA V5.4cisa_csaf_ot
Currently no fix is available
- Kein Fix verfügbarSIMOTION SCOUT TIA V5.5cisa_csaf_ot
Currently no fix is available
- Kein Fix verfügbarSINAMICS Startdrive V17cisa_csaf_ot
Currently no fix is available
- Kein Fix verfügbarSINAMICS Startdrive V18cisa_csaf_ot
Currently no fix is available
- Kein Fix verfügbarSINAMICS Startdrive V19cisa_csaf_ot
Currently no fix is available
- Kein Fix verfügbarSIRIUS Safety ES V17 (TIA Portal)cisa_csaf_ot
Currently no fix is available
- Kein Fix verfügbarSIRIUS Safety ES V18 (TIA Portal)cisa_csaf_ot
Currently no fix is available
- Kein Fix verfügbarSIRIUS Safety ES V19 (TIA Portal)cisa_csaf_ot
Currently no fix is available
- Kein Fix verfügbarSIRIUS Soft Starter ES V17 (TIA Portal)cisa_csaf_ot
Currently no fix is available
- Kein Fix verfügbarSIRIUS Soft Starter ES V18 (TIA Portal)cisa_csaf_ot
Currently no fix is available
- Kein Fix verfügbarSIRIUS Soft Starter ES V19 (TIA Portal)cisa_csaf_ot
Currently no fix is available
- Kein Fix verfügbarTIA Portal Cloud V17cisa_csaf_ot
Currently no fix is available
- Kein Fix verfügbarTIA Portal Cloud V18cisa_csaf_ot
Currently no fix is available
- Kein Fix geplantSIMATIC S7-PLCSIM V17siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIMATIC S7-PLCSIM V18siemens_psirt
Currently no fix is planned
cvss
Technischer Schweregrad, 0–10. Eine Zeile je Quelle.
Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen⚠ Quellen uneinig · medium–high · 4–7.3
SSVC
Eine Handlungsentscheidung — aus Ausnutzung und Auswirkung.
schwächen
Die CWE-Schwächeklassen, zu denen dies gehört.
betroffene Produkte (199)
Betroffene Produkte und Versionsbereiche.
Advisories (4)
Hersteller- und Ökosystem-Meldungen dazu.
- NCSC-2024-0473Kwetsbaarheden verholpen in Siemens productenNL2024-12-10csaf · ncsc_nlNL
Siemens heeft kwetsbaarheden verholpen in diverse producten als COMOS, RUGGEDCOM, SENTRON, SICAM, SIMATIC en TeamCenter.
- SSA-392859SSA-392859: Local Arbitrary Code Execution Vulnerability in Siemens Engineering Platforms before V202024-12-10csaf · siemens_psirtDE
Affected products contain a local arbitrary code execution vulnerability that could allow an attacker to perform actions against the operation system of that environment. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends countermeasures for products where fixes are not, or not yet available. Siemens has released products based on the Totally Integrated Automation Portal (TIA Portal) V20 which are not affected by CVE-2024-52051. See the chapter "Additional Information" below for more details.
- WID-SEC-W-2024-3656Siemens SIMATIC S7: Mehrere Schwachstellen ermöglichen CodeausführungDeutsch2024-12-10csaf · cert_bundDE
Ein lokaler Angreifer kann mehrere Schwachstellen in Siemens SIMATIC S7 ausnutzen, um beliebigen Programmcode auszuführen.
- ICSA-24-347-02Siemens Engineering Platforms2024-12-10icsa · cisa_csaf_otUS
Affected products contain a local arbitrary code execution vulnerability that could allow an attacker to perform actions against the operation system of that environment. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends countermeasures for products where fixes are not, or not yet available. Siemens has released products based on the Totally Integrated Automation Portal (TIA Portal) V20 which are not affected by CVE-2024-52051. See the chapter "Additional Information" below for more details.