CVE-2024-45463
highPriorität · verfolgen · 31EPSS 0.003 · 18. PerzentilDEEUNLUSEPSS · bewertet 2026-10-27
A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12), Teamcenter Visualization V2312 (All versions < V2312.0008), Tecnomatix Plant Simulation V2302 (All versions < V2302.0016), Tecnomatix Plant Simulation V2404 (All versions < V2404.0005). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process.
Behebungen
Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.
Ein Hersteller-Fix ist verfügbar.
- BehobenTecnomatix Plant Simulation V2302siemens_psirt
Update to V2302.0016 or later version
- BehobenTecnomatix Plant Simulation V2404siemens_psirt
Update to V2404.0005 or later version
- BehobenTeamcenter Visualization V14.2siemens_psirt
Update to V14.2.0.14 or later version
- BehobenTeamcenter Visualization V14.3siemens_psirt
Update to V14.3.0.12 or later version
- BehobenTeamcenter Visualization V2312siemens_psirt
Update to V2312.0008 or later version
- BehobenTecnomatix Plant Simulation V2302cisa_csaf_ot
Update to V2302.0016 or later version
- BehobenTecnomatix Plant Simulation V2404cisa_csaf_ot
Update to V2404.0005 or later version
- BehobenTeamcenter Visualization V14.2cisa_csaf_ot
Update to V14.2.0.14 or later version
- BehobenTeamcenter Visualization V14.3cisa_csaf_ot
Update to V14.3.0.12 or later version
- BehobenTeamcenter Visualization V2312cisa_csaf_ot
Update to V2312.0008 or later version
- MitigationTecnomatix Plant Simulation V2302siemens_psirt
Do not open untrusted WRL files in affected applications
- MitigationTecnomatix Plant Simulation V2404siemens_psirt
Do not open untrusted WRL files in affected applications
- MitigationTeamcenter Visualization V14.2siemens_psirt
Do not open untrusted WRL files in affected applications
- MitigationTeamcenter Visualization V14.3siemens_psirt
Do not open untrusted WRL files in affected applications
- MitigationTeamcenter Visualization V2312siemens_psirt
Do not open untrusted WRL files in affected applications
- MitigationTecnomatix Plant Simulation V2302cisa_csaf_ot
Do not open untrusted WRL files in affected applications
- MitigationTecnomatix Plant Simulation V2404cisa_csaf_ot
Do not open untrusted WRL files in affected applications
- MitigationTeamcenter Visualization V14.2cisa_csaf_ot
Do not open untrusted WRL files in affected applications
- MitigationTeamcenter Visualization V14.3cisa_csaf_ot
Do not open untrusted WRL files in affected applications
- MitigationTeamcenter Visualization V2312cisa_csaf_ot
Do not open untrusted WRL files in affected applications
cvss
Technischer Schweregrad, 0–10. Eine Zeile je Quelle.
Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen⚠ Quellen uneinig · medium–high · 4.4–7.8
SSVC
Eine Handlungsentscheidung — aus Ausnutzung und Auswirkung.
schwächen
Die CWE-Schwächeklassen, zu denen dies gehört.
betroffene Produkte (30)
Betroffene Produkte und Versionsbereiche.
- teamcenter_visualization_v14.2alle Versionenncsc_nlNLcpe:2.3:a:siemens:teamcenter_visualization_v14.2:*:*:*:*:*:*:*:*
- teamcenter_visualization_v14.3alle Versionenncsc_nlNLcpe:2.3:a:siemens:teamcenter_visualization_v14.3:*:*:*:*:*:*:*:*
- teamcenter_visualization_v2312alle Versionenncsc_nlNLcpe:2.3:a:siemens:teamcenter_visualization_v2312:*:*:*:*:*:*:*:*
- tecnomatix_plant_simulation_v2302alle Versionenncsc_nlNLcpe:2.3:a:siemens:tecnomatix_plant_simulation_v2302:0:*:*:*:*:*:*:*
- tecnomatix_plant_simulation_v2302alle Versionenncsc_nlNLcpe:2.3:a:siemens:tecnomatix_plant_simulation_v2302:*:*:*:*:*:*:*:*
Advisories (6)
Hersteller- und Ökosystem-Meldungen dazu.
- NCSC-2024-0390Kwetsbaarheden verholpen in Siemens productenNL2024-10-08csaf · ncsc_nlNL
Siemens heeft kwetsbaarheden verholpen in diverse producten als Questa/ModelSIM, RUGGEDCOM, SENTRON, SIMATIC, SINEC, Tecnomatix en Teamcenter.
- NCSC-2024-0473Kwetsbaarheden verholpen in Siemens productenNL2024-12-10csaf · ncsc_nlNL
Siemens heeft kwetsbaarheden verholpen in diverse producten als COMOS, RUGGEDCOM, SENTRON, SICAM, SIMATIC en TeamCenter.
- SSA-583523SSA-583523: Multiple WRL File Parsing Vulnerabilities in Tecnomatix Plant Simulation2024-10-08csaf · siemens_psirtDE
Siemens Tecnomatix Plant Simulation contains multiple file parsing vulnerabilities that could be triggered when the application reads files in WRL format. If a user is tricked to open a malicious file with any of the affected products, this could lead the application to crash or potentially lead to arbitrary code execution. Siemens has released new versions for the affected products and recommends to update to the latest versions.
- SSA-645131SSA-645131: Multiple WRL File Parsing Vulnerabilities in Teamcenter Visualization2024-12-10csaf · siemens_psirtDE
Siemens Teamcenter Visualization contains multiple file parsing vulnerabilities that could be triggered when the application reads files in WRL format. If a user is tricked to open a malicious file with any of the affected products, this could lead the application to crash or potentially lead to arbitrary code execution. Siemens has released new versions for the affected products and recommends to update to the latest versions.
- ICSA-24-284-13Siemens Tecnomatix Plant Simulation2024-10-08icsa · cisa_csaf_otUS
Siemens Tecnomatix Plant Simulation contains multiple file parsing vulnerabilities that could be triggered when the application reads files in WRL format. If a user is tricked to open a malicious file with any of the affected products, this could lead the application to crash or potentially lead to arbitrary code execution. Siemens has released new versions for the affected products and recommends to update to the latest versions.
- ICSA-24-347-09Siemens Teamcenter Visualization 2024-12-10icsa · cisa_csaf_otUS
Siemens Teamcenter Visualization contains multiple file parsing vulnerabilities that could be triggered when the application reads files in WRL format. If a user is tricked to open a malicious file with any of the affected products, this could lead the application to crash or potentially lead to arbitrary code execution. Siemens has released new versions for the affected products and recommends to update to the latest versions.
auch bekannt als (3)
Weitere Namen und Kennungen dieser Entität.
quellen
Welche Quellen diesen Datensatz belegen und wann.
Referenzen (8)
Externe Belege — Patches, Meldungen, Analysen.
- https://cert-portal.siemens.com/productcert/html/ssa-583523.htmlcnnvd
- https://cert-portal.siemens.com/productcert/html/ssa-645131.htmlcnnvd
- https://cxsecurity.com/cveshow/CVE-2024-45463/cnnvd
- https://nvd.nist.gov/vuln/detail/CVE-2024-45463cnnvd
- https://cert-portal.siemens.com/productcert/html/ssa-583523.htmlenisa_euvd
- https://cert-portal.siemens.com/productcert/html/ssa-645131.htmlenisa_euvd
- https://cert-portal.siemens.com/productcert/html/ssa-583523.htmlVendor Advisorynvd
- https://cert-portal.siemens.com/productcert/html/ssa-645131.htmlnvd
Angreifer nutzen Schwachstellen wie diese gegen im Internet exponierte Dienste aus. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.