CVE-2024-44990

mediumPriorität · verfolgen · 22EPSS 0.002 · 15. PerzentilDEEURUUS
grimoire priorityP3 · Track
Exploitable?
—
no known exploitation
Likely / severe?
0.24% (15th) EPSS
CVSS 5.5 · medium
Is it mine?
63 products
Prüfe deine Angriffsfläche
Who says so?
6 sources
cnnvd · enisa_euvd · fstec_bdu · cert_bund

EPSS · bewertet 2026-10-27

In the Linux kernel, the following vulnerability has been resolved: bonding: fix null pointer deref in bond_ipsec_offload_ok We must check if there is an active slave before dereferencing the pointer.

01

Behebungen

Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.

Ein Hersteller-Fix ist verfügbar.

02

cvss

Technischer Schweregrad, 0–10. Eine Zeile je Quelle.

5.5
010

Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen

v3.15.5mediumCVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:Hprimary · NVD / NIST USAusnutzbarkeit 1.8 · Auswirkung 3.6
v3.15.5mediumCVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:Hsecondary · CISA US
v3.15.5mediumAV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:Hsecondary · FSTEC (BDU) RU
v3.15.5mediumCVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:Hsecondary · Siemens ProductCERT DE
v3.15.1mediumCVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:Usecondary · CVSS-BT (t0sche)
03

SSVC

Eine Handlungsentscheidung — aus Ausnutzung und Auswirkung.

Trackcoordinatorcisa_ssvcUS
04

schwächen

Die CWE-Schwächeklassen, zu denen dies gehört.

05

betroffene Produkte (63)

Betroffene Produkte und Versionsbereiche.

20 von 63 angezeigt
06

Advisories (7)

Hersteller- und Ökosystem-Meldungen dazu.

  • SSA-265688SSA-265688: Vulnerabilities in the additional GNU/Linux subsystem of the SIMATIC S7-1500 TM MFP V1.12024-04-09csaf · siemens_psirtDE

    Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the SIMATIC S7-1500 TM MFP V1.1. Siemens has released a new version for SIMATIC S7-1500 TM MFP - GNU/Linux subsystem and recommends to update to the latest version. Siemens is preparing further fixes and recommends specific mitigations for products where fixes are not or not yet available. SIMATIC S7-1500 TM MFP V1.1 is no longer maintained and there won't be any update to the CVE list anymore. Please update to the latest version. Note: This SSA advises vulnerabilities for firmware version V1.1 only; for version V1.1.1 refer to SSA-784472.

  • SSA-355557SSA-355557: Multiple Vulnerabilities in Third-Party Components in SINEC OS before V3.22025-08-12csaf · siemens_psirtDE

    SINEC OS before V3.2 contains third-party components with multiple vulnerabilities. Siemens has released new versions for the affected products and recommends to update to the latest versions.

  • SSA-613116SSA-613116: Multiple Vulnerabilities in Third-Party Components in SINEC OS before V3.12025-08-12csaf · siemens_psirtDE

    SINEC OS before V3.1 contains third-party components with multiple vulnerabilities. Siemens has released new versions for the affected products and recommends to update to the latest versions.

  • WID-SEC-W-2024-2057Linux Kernel: Mehrere Schwachstellen ermöglichen Denial of Service oder unspezifischer AngriffDeutsch2024-09-04csaf · cert_bundDE

    Ein lokaler Angreifer kann mehrere Schwachstellen in Linux Kernel ausnutzen, um einen Denial of Service Angriff durchzuführen oder weitere unspezifische Angriffe durchzuführen.

  • ICSA-24-102-01Siemens SIMATIC S7-1500 TM MFP2024-04-09icsa · cisa_csaf_otUS

    Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the SIMATIC S7-1500 TM MFP V1.1. Siemens is preparing fix versions and recommends specific countermeasures for products where fixes are not, or not yet available.

  • ICSA-25-226-07Siemens Third-Party Components in SINEC OS2025-08-12icsa · cisa_csaf_otUS

    SINEC OS before V3.2 contains third-party components with multiple vulnerabilities. Siemens has released new versions for the affected products and recommends to update to the latest versions.

  • ICSA-25-226-15Siemens SINEC OS2025-08-12icsa · cisa_csaf_otUS

    SINEC OS before V3.1 contains third-party components with multiple vulnerabilities. Siemens has released new versions for the affected products and recommends to update to the latest versions.