CVE-2024-43781

mediumPriorität · verfolgen · 0EPSS 0.002 · 4. PerzentilDEEUNLRUUS
grimoire priorityP3 · Track
Exploitable?
—
no known exploitation
Likely / severe?
0.15% (4th) EPSS
CVSS 5.5 · medium
Is it mine?
25 products
Prüfe deine Angriffsfläche
Who says so?
6 sources
cnnvd · enisa_euvd · fstec_bdu · cisa_csaf_ot

EPSS · bewertet 2026-10-22

A vulnerability has been identified in SINUMERIK 828D V4 (All versions < V4.95 SP3), SINUMERIK 840D sl V4 (All versions < V4.95 SP3 in connection with using Create MyConfig (CMC) <= V4.8 SP1 HF6), SINUMERIK ONE (All versions < V6.23 in connection with using Create MyConfig (CMC) <= V6.6), SINUMERIK ONE (All versions < V6.15 SP4 in connection with using Create MyConfig (CMC) <= V6.6). Affected systems, that have been provisioned with Create MyConfig (CMC), contain a Insertion of Sensitive Information into Log File vulnerability. This could allow a local authenticated user with low privileges to read sensitive information and thus circumvent access restrictions.

01

Behebungen

Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.

Ein Hersteller-Fix ist verfügbar.

  • BehobenSINUMERIK 828D V4siemens_psirt

    Update to V4.95 SP3 or later version

  • BehobenSINUMERIK 840D sl V4siemens_psirt

    Update to V4.95 SP3 or later version

  • BehobenSINUMERIK ONEsiemens_psirt

    Update to V6.15 SP4 or later version

  • BehobenSINUMERIK 828D V4cisa_csaf_ot

    Update to V4.95 SP3 or later version

  • BehobenSINUMERIK 840D sl V4cisa_csaf_ot

    Update to V4.95 SP3 or later version

  • BehobenSINUMERIK ONEcisa_csaf_ot

    Update to V6.15 SP4 or later version

  • MitigationSINUMERIK 828D V4siemens_psirt

    Delete the file(s) manually (after using CMC): - on an NCU: /card/user/sinumerik/hmi/log/sltrc/uptrace.out - on an IPC: c:\ProgramData\Siemens\MotionControl\user\sinumerik\hmi\log\sltrc\uptrace.out and the corresponding backup of the tracefile, uptrace.out.bak. Replace trace configuration to switch off trace for the future.

  • MitigationSINUMERIK 840D sl V4siemens_psirt

    Delete the file(s) manually (after using CMC): - on an NCU: /card/user/sinumerik/hmi/log/sltrc/uptrace.out - on an IPC: c:\ProgramData\Siemens\MotionControl\user\sinumerik\hmi\log\sltrc\uptrace.out and the corresponding backup of the tracefile, uptrace.out.bak. Replace trace configuration to switch off trace for the future.

  • MitigationSINUMERIK ONEsiemens_psirt

    Delete the file(s) manually (after using CMC): - on an NCU: /card/user/sinumerik/hmi/log/sltrc/uptrace.out - on an IPC: c:\ProgramData\Siemens\MotionControl\user\sinumerik\hmi\log\sltrc\uptrace.out and the corresponding backup of the tracefile, uptrace.out.bak. Replace trace configuration to switch off trace for the future.

  • MitigationSINUMERIK 828D V4cisa_csaf_ot

    Delete the file(s) manually (after using CMC): - on an NCU: /card/user/sinumerik/hmi/log/sltrc/uptrace.out - on an IPC: c:\ProgramData\Siemens\MotionControl\user\sinumerik\hmi\log\sltrc\uptrace.out and the corresponding backup of the tracefile, uptrace.out.bak. Replace trace configuration to switch off trace for the future.

  • MitigationSINUMERIK 840D sl V4cisa_csaf_ot

    Delete the file(s) manually (after using CMC): - on an NCU: /card/user/sinumerik/hmi/log/sltrc/uptrace.out - on an IPC: c:\ProgramData\Siemens\MotionControl\user\sinumerik\hmi\log\sltrc\uptrace.out and the corresponding backup of the tracefile, uptrace.out.bak. Replace trace configuration to switch off trace for the future.

  • MitigationSINUMERIK ONEcisa_csaf_ot

    Delete the file(s) manually (after using CMC): - on an NCU: /card/user/sinumerik/hmi/log/sltrc/uptrace.out - on an IPC: c:\ProgramData\Siemens\MotionControl\user\sinumerik\hmi\log\sltrc\uptrace.out and the corresponding backup of the tracefile, uptrace.out.bak. Replace trace configuration to switch off trace for the future.

02

cvss

Technischer Schweregrad, 0–10. Eine Zeile je Quelle.

6.8
010

Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen

v3.15.5mediumCVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:Csecondary · NCSC-NL NL
v3.15.5mediumAV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:Nsecondary · FSTEC (BDU) RU
v3.15.5mediumCVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:Nsecondary · productcert@siemens.com DEAusnutzbarkeit 1.8 · Auswirkung 3.6
v3.15.5mediumCVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:Csecondary · Siemens ProductCERT DE
v3.15.5mediumCVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:Csecondary · CISA US
v4.06.8mediumCVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:Nsecondary · ENISA EU
v4.06.8mediumCVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:Xsecondary · productcert@siemens.com DE
v4.04.3mediumCVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:U/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:Xsecondary · CVSS-BT (t0sche)
03

SSVC

Eine Handlungsentscheidung — aus Ausnutzung und Auswirkung.

Trackcoordinatorcisa_ssvcUS
04

schwächen

Die CWE-Schwächeklassen, zu denen dies gehört.

05

betroffene Produkte (25)

Betroffene Produkte und Versionsbereiche.

20 von 25 angezeigt
06

Advisories (3)

Hersteller- und Ökosystem-Meldungen dazu.

  • NCSC-2024-0362Kwetsbaarheden verholpen in Siemens productenNL2024-09-10csaf · ncsc_nlNL

    Siemens heeft kwetsbaarheden verholpen in diverse producten als Mendix, SICAM, SIMATIC, SINEMA, SINUMERIK en Tecnomatix.

  • SSA-097786SSA-097786: Insertion of Sensitive Information into Log File Vulnerability in SINUMERIK systems2024-09-10csaf · siemens_psirtDE

    SINUMERIK systems, that have been provisioned with Create MyConfig (CMC), are affected by a Insertion of Sensitive Information into Log File vulnerability. When using a CMC package on a NCU or on an IPC the password used in the CMC package or typed in manually during package execution is traced on the machine to the file uptrace.out. This could allow a local authenticated user with low privileges to read that password and use it to impersonate a user with higher privileges. Siemens has released new versions for the affected products and recommends to update to the latest versions.

  • ICSA-24-256-04Siemens SINUMERIK Systems2024-09-10icsa · cisa_csaf_otUS

    SINUMERIK systems, that have been provisioned with Create MyConfig (CMC), are affected by a Insertion of Sensitive Information into Log File vulnerability. When using a CMC package on a NCU or on an IPC the password used in the CMC package or typed in manually during package execution is traced on the machine to the file uptrace.out. This could allow a local authenticated user with low privileges to read that password and use it to impersonate a user with higher privileges. Siemens has released new versions for the affected products and recommends to update to the latest versions.