CVE-2024-41908
highPriorität · verfolgen · 0EPSS 0.002 · 7. PerzentilDEEUNLUSEPSS · bewertet 2026-10-23
A vulnerability has been identified in NX (All versions < V2406.3000). The affected applications contains an out of bounds read vulnerability while parsing specially crafted PRT files. This could allow an attacker to crash the application or execute code in the context of the current process.
Behebungen
Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.
Ein Hersteller-Fix ist verfügbar.
- BehobenNXsiemens_psirt
Update to V2406.3000 or later version
- BehobenNXcisa_csaf_ot
Update to V2406.3000 or later version
- MitigationNXsiemens_psirt
Do not open untrusted PRT files from unknown sources
- MitigationNXcisa_csaf_ot
Do not open untrusted PRT files from unknown sources
cvss
Technischer Schweregrad, 0–10. Eine Zeile je Quelle.
Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen⚠ Quellen uneinig · medium–high · 4.4–7.8
SSVC
Eine Handlungsentscheidung — aus Ausnutzung und Auswirkung.
schwächen
Die CWE-Schwächeklassen, zu denen dies gehört.
betroffene Produkte (4)
Betroffene Produkte und Versionsbereiche.
Advisories (3)
Hersteller- und Ökosystem-Meldungen dazu.
- NCSC-2024-0332Kwetsbaarheden verholpen in Siemens productenNL2024-08-13csaf · ncsc_nlNL
Siemens heeft kwetsbaarheden verholpen in diverse producten als COMOS, INTRALOG, LOGO!, NX, SCALANCE, SINEC en Teamcenter.
- SSA-357412SSA-357412: PRT File Parsing Vulnerability in NX Before V2406.30002024-08-13csaf · siemens_psirtDE
NX (incl. NX student versions) before V2406.3000 contains an out-of-bounds read vulnerability that could be triggered when the application reads PRT files. If a user is tricked to open a malicious file using the affected application, this could lead to a crash, and potentially also to arbitrary code execution on the target host system. Siemens has released a new version for NX and recommends to update to the latest version.
- ICSA-24-228-09Siemens NX2024-08-13icsa · cisa_csaf_otUS
NX (incl. NX student versions) before V2406.3000 contains an out-of-bounds read vulnerability that could be triggered when the application reads PRT files. If a user is tricked to open a malicious file using the affected application, this could lead to a crash, and potentially also to arbitrary code execution on the target host system. Siemens has released a new version for NX and recommends to update to the latest version.
auch bekannt als (3)
Weitere Namen und Kennungen dieser Entität.
quellen
Welche Quellen diesen Datensatz belegen und wann.
Referenzen (4)
Externe Belege — Patches, Meldungen, Analysen.
Angreifer nutzen Schwachstellen wie diese gegen im Internet exponierte Dienste aus. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.
Kostenloser Scan