CVE-2024-40978

highPriorität · verfolgen · 28EPSS 0.003 · 25. PerzentilDEEURUUS
grimoire priorityP2 · Scheduled
Exploitable?
—
no known exploitation
Likely / severe?
0.32% (25th) EPSS
CVSS 7.1 · high
Is it mine?
123 products
Prüfe deine Angriffsfläche
Who says so?
6 sources
cnnvd · enisa_euvd · fstec_bdu · cert_bund

EPSS · bewertet 2026-10-27

In the Linux kernel, the following vulnerability has been resolved: scsi: qedi: Fix crash while reading debugfs attribute The qedi_dbg_do_not_recover_cmd_read() function invokes sprintf() directly on a __user pointer, which results into the crash. To fix this issue, use a small local stack buffer for sprintf() and then call simple_read_from_buffer(), which in turns make the copy_to_user() call. BUG: unable to handle page fault for address: 00007f4801111000 PGD 8000000864df6067 P4D 8000000864df6067 PUD 864df7067 PMD 846028067 PTE 0 Oops: 0002 [#1] PREEMPT SMP PTI Hardware name: HPE ProLiant DL380 Gen10/ProLiant DL380 Gen10, BIOS U30 06/15/2023 RIP: 0010:memcpy_orig+0xcd/0x130 RSP: 0018:ffffb7a18c3ffc40 EFLAGS: 00010202 RAX: 00007f4801111000 RBX: 00007f4801111000 RCX: 000000000000000f RDX: 000000000000000f RSI: ffffffffc0bfd7a0 RDI: 00007f4801111000 RBP: ffffffffc0bfd7a0 R08: 725f746f6e5f6f64 R09: 3d7265766f636572 R10: ffffb7a18c3ffd08 R11: 0000000000000000 R12: 00007f4881110fff R13: 000000007fffffff R14: ffffb7a18c3ffca0 R15: ffffffffc0bfd7af FS: 00007f480118a740(0000) GS:ffff98e38af00000(0000) knlGS:0000000000000000 CS: 0010 DS: 0000 ES: 0000 CR0: 0000000080050033 CR2: 00007f4801111000 CR3: 0000000864b8e001 CR4: 00000000007706e0 DR0: 0000000000000000 DR1: 0000000000000000 DR2: 0000000000000000 DR3: 0000000000000000 DR6: 00000000fffe0ff0 DR7: 0000000000000400 PKRU: 55555554 Call Trace: <TASK> ? __die_body+0x1a/0x60 ? page_fault_oops+0x183/0x510 ? exc_page_fault+0x69/0x150 ? asm_exc_page_fault+0x22/0x30 ? memcpy_orig+0xcd/0x130 vsnprintf+0x102/0x4c0 sprintf+0x51/0x80 qedi_dbg_do_not_recover_cmd_read+0x2f/0x50 [qedi 6bcfdeeecdea037da47069eca2ba717c84a77324] full_proxy_read+0x50/0x80 vfs_read+0xa5/0x2e0 ? folio_add_new_anon_rmap+0x44/0xa0 ? set_pte_at+0x15/0x30 ? do_pte_missing+0x426/0x7f0 ksys_read+0xa5/0xe0 do_syscall_64+0x58/0x80 ? __count_memcg_events+0x46/0x90 ? count_memcg_event_mm+0x3d/0x60 ? handle_mm_fault+0x196/0x2f0 ? do_user_addr_fault+0x267/0x890 ? exc_page_fault+0x69/0x150 entry_SYSCALL_64_after_hwframe+0x72/0xdc RIP: 0033:0x7f4800f20b4d

01

Behebungen

Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.

Ein Hersteller-Fix ist verfügbar.

  • BehobenSIMATIC S7-1500 TM MFP - GNU/Linux subsystemsiemens_psirt

    Update to V1.1.1 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109827684/
  • MitigationSIMATIC S7-1500 TM MFP - GNU/Linux subsystemsiemens_psirt

    Limit access to the interactive shell of the additional GNU/Linux subssytem to trusted personnel only.

  • MitigationSIMATIC S7-1500 TM MFP - GNU/Linux subsystemcisa_csaf_ot

    Limit access to the interactive shell of the additional GNU/Linux subssytem to trusted personnel only.

  • Kein Fix verfügbarSIMATIC S7-1500 TM MFP - GNU/Linux subsystemcisa_csaf_ot

    Currently no fix is available

02

cvss

Technischer Schweregrad, 0–10. Eine Zeile je Quelle.

7.1
010

Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen⚠ Quellen uneinig · medium–high · 5.5–7.1

v3.17.1highCVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:Hprimary · NVD / NIST USAusnutzbarkeit 1.8 · Auswirkung 5.2
v3.16.2mediumCVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:Hsecondary · CISA US
v3.15.5mediumAV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:Hsecondary · FSTEC (BDU) RU
v3.16.2mediumCVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:Hsecondary · Siemens ProductCERT DE
v3.16.5mediumCVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:H/E:Usecondary · CVSS-BT (t0sche)
03

SSVC

Eine Handlungsentscheidung — aus Ausnutzung und Auswirkung.

Trackcoordinatorcisa_ssvcUS
04

schwächen

Die CWE-Schwächeklassen, zu denen dies gehört.

05

betroffene Produkte (123)

Betroffene Produkte und Versionsbereiche.

20 von 123 angezeigt
06

Advisories (5)

Hersteller- und Ökosystem-Meldungen dazu.

  • SSA-265688SSA-265688: Vulnerabilities in the additional GNU/Linux subsystem of the SIMATIC S7-1500 TM MFP V1.12024-04-09csaf · siemens_psirtDE

    Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the SIMATIC S7-1500 TM MFP V1.1. Siemens has released a new version for SIMATIC S7-1500 TM MFP - GNU/Linux subsystem and recommends to update to the latest version. Siemens is preparing further fixes and recommends specific mitigations for products where fixes are not or not yet available. SIMATIC S7-1500 TM MFP V1.1 is no longer maintained and there won't be any update to the CVE list anymore. Please update to the latest version. Note: This SSA advises vulnerabilities for firmware version V1.1 only; for version V1.1.1 refer to SSA-784472.

  • SSA-355557SSA-355557: Multiple Vulnerabilities in Third-Party Components in SINEC OS before V3.22025-08-12csaf · siemens_psirtDE

    SINEC OS before V3.2 contains third-party components with multiple vulnerabilities. Siemens has released new versions for the affected products and recommends to update to the latest versions.

  • WID-SEC-W-2024-1607Linux Kernel: Mehrere SchwachstellenDeutsch2024-07-14csaf · cert_bundDE

    Ein lokaler Angreifer kann mehrere Schwachstellen im Linux-Kernel ausnutzen, um seine Privilegien zu erweitern, einen Denial-of-Service-Zustand zu erzeugen, vertrauliche Informationen offenzulegen oder einen unspezifischen Angriff durchzuführen.

  • ICSA-24-102-01Siemens SIMATIC S7-1500 TM MFP2024-04-09icsa · cisa_csaf_otUS

    Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the SIMATIC S7-1500 TM MFP V1.1. Siemens is preparing fix versions and recommends specific countermeasures for products where fixes are not, or not yet available.

  • ICSA-25-226-07Siemens Third-Party Components in SINEC OS2025-08-12icsa · cisa_csaf_otUS

    SINEC OS before V3.2 contains third-party components with multiple vulnerabilities. Siemens has released new versions for the affected products and recommends to update to the latest versions.

07

auch bekannt als (4)

Weitere Namen und Kennungen dieser Entität.

08

quellen

Welche Quellen diesen Datensatz belegen und wann.

10

Referenzen (29)

Externe Belege — Patches, Meldungen, Analysen.

scry

Angreifer nutzen Schwachstellen wie diese gegen im Internet exponierte Dienste aus. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.

Kostenloser Scan