CVE-2024-35292
highPriorität · verfolgen · 0OT-Risiko · erhöhtEPSS 0.004 · 33. PerzentilDEEUNLRUUSEPSS · bewertet 2026-10-26
A vulnerability has been identified in SIMATIC S7-200 SMART CPU CR40 (6ES7288-1CR40-0AA0) (All versions), SIMATIC S7-200 SMART CPU CR60 (6ES7288-1CR60-0AA0) (All versions), SIMATIC S7-200 SMART CPU SR20 (6ES7288-1SR20-0AA0) (All versions), SIMATIC S7-200 SMART CPU SR20 (6ES7288-1SR20-0AA1) (All versions), SIMATIC S7-200 SMART CPU SR30 (6ES7288-1SR30-0AA0) (All versions), SIMATIC S7-200 SMART CPU SR30 (6ES7288-1SR30-0AA1) (All versions), SIMATIC S7-200 SMART CPU SR40 (6ES7288-1SR40-0AA0) (All versions), SIMATIC S7-200 SMART CPU SR40 (6ES7288-1SR40-0AA1) (All versions), SIMATIC S7-200 SMART CPU SR60 (6ES7288-1SR60-0AA0) (All versions), SIMATIC S7-200 SMART CPU SR60 (6ES7288-1SR60-0AA1) (All versions), SIMATIC S7-200 SMART CPU ST20 (6ES7288-1ST20-0AA0) (All versions), SIMATIC S7-200 SMART CPU ST20 (6ES7288-1ST20-0AA1) (All versions), SIMATIC S7-200 SMART CPU ST30 (6ES7288-1ST30-0AA0) (All versions), SIMATIC S7-200 SMART CPU ST30 (6ES7288-1ST30-0AA1) (All versions), SIMATIC S7-200 SMART CPU ST40 (6ES7288-1ST40-0AA0) (All versions), SIMATIC S7-200 SMART CPU ST40 (6ES7288-1ST40-0AA1) (All versions), SIMATIC S7-200 SMART CPU ST60 (6ES7288-1ST60-0AA0) (All versions), SIMATIC S7-200 SMART CPU ST60 (6ES7288-1ST60-0AA1) (All versions). Affected devices are using a predictable IP ID sequence number. This leaves the system susceptible to a family of attacks which rely on the use of predictable IP ID sequence numbers as their base method of attack and eventually could allow an attacker to create a denial of service condition.
Behebungen
Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.
Noch kein Hersteller-Fix; eine Mitigation ist verfügbar.
- MitigationSIMATIC S7-200 SMART CPU CR40 (6ES7288-1CR40-0AA0)siemens_psirt
Restrict access to the network where the affected products are located by introducing strict access control mechanisms
- MitigationSIMATIC S7-200 SMART CPU CR60 (6ES7288-1CR60-0AA0)siemens_psirt
Restrict access to the network where the affected products are located by introducing strict access control mechanisms
- MitigationSIMATIC S7-200 SMART CPU SR20 (6ES7288-1SR20-0AA0)siemens_psirt
Restrict access to the network where the affected products are located by introducing strict access control mechanisms
- MitigationSIMATIC S7-200 SMART CPU SR20 (6ES7288-1SR20-0AA1)siemens_psirt
Restrict access to the network where the affected products are located by introducing strict access control mechanisms
- MitigationSIMATIC S7-200 SMART CPU SR30 (6ES7288-1SR30-0AA0)siemens_psirt
Restrict access to the network where the affected products are located by introducing strict access control mechanisms
- MitigationSIMATIC S7-200 SMART CPU SR30 (6ES7288-1SR30-0AA1)siemens_psirt
Restrict access to the network where the affected products are located by introducing strict access control mechanisms
- MitigationSIMATIC S7-200 SMART CPU SR40 (6ES7288-1SR40-0AA0)siemens_psirt
Restrict access to the network where the affected products are located by introducing strict access control mechanisms
- MitigationSIMATIC S7-200 SMART CPU SR40 (6ES7288-1SR40-0AA1)siemens_psirt
Restrict access to the network where the affected products are located by introducing strict access control mechanisms
- MitigationSIMATIC S7-200 SMART CPU SR60 (6ES7288-1SR60-0AA0)siemens_psirt
Restrict access to the network where the affected products are located by introducing strict access control mechanisms
- MitigationSIMATIC S7-200 SMART CPU SR60 (6ES7288-1SR60-0AA1)siemens_psirt
Restrict access to the network where the affected products are located by introducing strict access control mechanisms
- MitigationSIMATIC S7-200 SMART CPU ST20 (6ES7288-1ST20-0AA0)siemens_psirt
Restrict access to the network where the affected products are located by introducing strict access control mechanisms
- MitigationSIMATIC S7-200 SMART CPU ST20 (6ES7288-1ST20-0AA1)siemens_psirt
Restrict access to the network where the affected products are located by introducing strict access control mechanisms
- MitigationSIMATIC S7-200 SMART CPU ST30 (6ES7288-1ST30-0AA0)siemens_psirt
Restrict access to the network where the affected products are located by introducing strict access control mechanisms
- MitigationSIMATIC S7-200 SMART CPU ST30 (6ES7288-1ST30-0AA1)siemens_psirt
Restrict access to the network where the affected products are located by introducing strict access control mechanisms
- MitigationSIMATIC S7-200 SMART CPU ST40 (6ES7288-1ST40-0AA0)siemens_psirt
Restrict access to the network where the affected products are located by introducing strict access control mechanisms
- MitigationSIMATIC S7-200 SMART CPU ST40 (6ES7288-1ST40-0AA1)siemens_psirt
Restrict access to the network where the affected products are located by introducing strict access control mechanisms
- MitigationSIMATIC S7-200 SMART CPU ST60 (6ES7288-1ST60-0AA0)siemens_psirt
Restrict access to the network where the affected products are located by introducing strict access control mechanisms
- MitigationSIMATIC S7-200 SMART CPU ST60 (6ES7288-1ST60-0AA1)siemens_psirt
Restrict access to the network where the affected products are located by introducing strict access control mechanisms
- MitigationSIMATIC S7-200 SMART CPU CR40 (6ES7288-1CR40-0AA0)cisa_csaf_ot
Restrict access to the network where the affected products are located by introducing strict access control mechanisms
- MitigationSIMATIC S7-200 SMART CPU CR60 (6ES7288-1CR60-0AA0)cisa_csaf_ot
Restrict access to the network where the affected products are located by introducing strict access control mechanisms
- MitigationSIMATIC S7-200 SMART CPU SR20 (6ES7288-1SR20-0AA0)cisa_csaf_ot
Restrict access to the network where the affected products are located by introducing strict access control mechanisms
- MitigationSIMATIC S7-200 SMART CPU SR20 (6ES7288-1SR20-0AA1)cisa_csaf_ot
Restrict access to the network where the affected products are located by introducing strict access control mechanisms
- MitigationSIMATIC S7-200 SMART CPU SR30 (6ES7288-1SR30-0AA0)cisa_csaf_ot
Restrict access to the network where the affected products are located by introducing strict access control mechanisms
- MitigationSIMATIC S7-200 SMART CPU SR30 (6ES7288-1SR30-0AA1)cisa_csaf_ot
Restrict access to the network where the affected products are located by introducing strict access control mechanisms
- MitigationSIMATIC S7-200 SMART CPU SR40 (6ES7288-1SR40-0AA0)cisa_csaf_ot
Restrict access to the network where the affected products are located by introducing strict access control mechanisms
- MitigationSIMATIC S7-200 SMART CPU SR40 (6ES7288-1SR40-0AA1)cisa_csaf_ot
Restrict access to the network where the affected products are located by introducing strict access control mechanisms
- MitigationSIMATIC S7-200 SMART CPU SR60 (6ES7288-1SR60-0AA0)cisa_csaf_ot
Restrict access to the network where the affected products are located by introducing strict access control mechanisms
- MitigationSIMATIC S7-200 SMART CPU SR60 (6ES7288-1SR60-0AA1)cisa_csaf_ot
Restrict access to the network where the affected products are located by introducing strict access control mechanisms
- MitigationSIMATIC S7-200 SMART CPU ST20 (6ES7288-1ST20-0AA0)cisa_csaf_ot
Restrict access to the network where the affected products are located by introducing strict access control mechanisms
- MitigationSIMATIC S7-200 SMART CPU ST20 (6ES7288-1ST20-0AA1)cisa_csaf_ot
Restrict access to the network where the affected products are located by introducing strict access control mechanisms
- MitigationSIMATIC S7-200 SMART CPU ST30 (6ES7288-1ST30-0AA0)cisa_csaf_ot
Restrict access to the network where the affected products are located by introducing strict access control mechanisms
- MitigationSIMATIC S7-200 SMART CPU ST30 (6ES7288-1ST30-0AA1)cisa_csaf_ot
Restrict access to the network where the affected products are located by introducing strict access control mechanisms
- MitigationSIMATIC S7-200 SMART CPU ST40 (6ES7288-1ST40-0AA0)cisa_csaf_ot
Restrict access to the network where the affected products are located by introducing strict access control mechanisms
- MitigationSIMATIC S7-200 SMART CPU ST40 (6ES7288-1ST40-0AA1)cisa_csaf_ot
Restrict access to the network where the affected products are located by introducing strict access control mechanisms
- MitigationSIMATIC S7-200 SMART CPU ST60 (6ES7288-1ST60-0AA0)cisa_csaf_ot
Restrict access to the network where the affected products are located by introducing strict access control mechanisms
- MitigationSIMATIC S7-200 SMART CPU ST60 (6ES7288-1ST60-0AA1)cisa_csaf_ot
Restrict access to the network where the affected products are located by introducing strict access control mechanisms
- Kein Fix geplantSIMATIC S7-200 SMART CPU CR40 (6ES7288-1CR40-0AA0)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIMATIC S7-200 SMART CPU CR60 (6ES7288-1CR60-0AA0)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIMATIC S7-200 SMART CPU SR20 (6ES7288-1SR20-0AA0)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIMATIC S7-200 SMART CPU SR20 (6ES7288-1SR20-0AA1)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIMATIC S7-200 SMART CPU SR30 (6ES7288-1SR30-0AA0)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIMATIC S7-200 SMART CPU SR30 (6ES7288-1SR30-0AA1)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIMATIC S7-200 SMART CPU SR40 (6ES7288-1SR40-0AA0)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIMATIC S7-200 SMART CPU SR40 (6ES7288-1SR40-0AA1)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIMATIC S7-200 SMART CPU SR60 (6ES7288-1SR60-0AA0)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIMATIC S7-200 SMART CPU SR60 (6ES7288-1SR60-0AA1)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIMATIC S7-200 SMART CPU ST20 (6ES7288-1ST20-0AA0)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIMATIC S7-200 SMART CPU ST20 (6ES7288-1ST20-0AA1)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIMATIC S7-200 SMART CPU ST30 (6ES7288-1ST30-0AA0)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIMATIC S7-200 SMART CPU ST30 (6ES7288-1ST30-0AA1)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIMATIC S7-200 SMART CPU ST40 (6ES7288-1ST40-0AA0)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIMATIC S7-200 SMART CPU ST40 (6ES7288-1ST40-0AA1)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIMATIC S7-200 SMART CPU ST60 (6ES7288-1ST60-0AA0)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIMATIC S7-200 SMART CPU ST60 (6ES7288-1ST60-0AA1)siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIMATIC S7-200 SMART CPU CR40 (6ES7288-1CR40-0AA0)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIMATIC S7-200 SMART CPU CR60 (6ES7288-1CR60-0AA0)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIMATIC S7-200 SMART CPU SR20 (6ES7288-1SR20-0AA0)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIMATIC S7-200 SMART CPU SR20 (6ES7288-1SR20-0AA1)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIMATIC S7-200 SMART CPU SR30 (6ES7288-1SR30-0AA0)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIMATIC S7-200 SMART CPU SR30 (6ES7288-1SR30-0AA1)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIMATIC S7-200 SMART CPU SR40 (6ES7288-1SR40-0AA0)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIMATIC S7-200 SMART CPU SR40 (6ES7288-1SR40-0AA1)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIMATIC S7-200 SMART CPU SR60 (6ES7288-1SR60-0AA0)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIMATIC S7-200 SMART CPU SR60 (6ES7288-1SR60-0AA1)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIMATIC S7-200 SMART CPU ST20 (6ES7288-1ST20-0AA0)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIMATIC S7-200 SMART CPU ST20 (6ES7288-1ST20-0AA1)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIMATIC S7-200 SMART CPU ST30 (6ES7288-1ST30-0AA0)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIMATIC S7-200 SMART CPU ST30 (6ES7288-1ST30-0AA1)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIMATIC S7-200 SMART CPU ST40 (6ES7288-1ST40-0AA0)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIMATIC S7-200 SMART CPU ST40 (6ES7288-1ST40-0AA1)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIMATIC S7-200 SMART CPU ST60 (6ES7288-1ST60-0AA0)cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantSIMATIC S7-200 SMART CPU ST60 (6ES7288-1ST60-0AA1)cisa_csaf_ot
Currently no fix is planned
cvss
Technischer Schweregrad, 0–10. Eine Zeile je Quelle.
Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen⚠ Quellen uneinig · medium–high · 6.7–8.8
SSVC
Eine Handlungsentscheidung — aus Ausnutzung und Auswirkung.
schwächen
Die CWE-Schwächeklassen, zu denen dies gehört.
betroffene Produkte (75)
Betroffene Produkte und Versionsbereiche.
Advisories (4)
Hersteller- und Ökosystem-Meldungen dazu.
- NCSC-2024-0246Kwetsbaarheden verholpen in Siemens productenNL2024-06-11csaf · ncsc_nlNL
Siemens heeft kwetsbaarheden verholpen in diverse producten, zoals SCALANCE, SICAM, Tecnomatix, SITOP en PowerSys.
- SSA-481506SSA-481506: Information Disclosure Vulnerability in SIMATIC S7-200 SMART Devices2024-06-11csaf · siemens_psirtDE
SIMATIC S7-200 SMART devices contain an information disclosure vulnerability which leaves the system susceptible to a family of attacks which rely on the use of predictable IP ID sequence numbers as their base method of attack and eventually could allow an attacker to create a denial of service condition. Siemens recommends specific countermeasures for products where fixes are not, or not yet available.
- WID-SEC-W-2024-1334Siemens SIMATIC S7: Schwachstelle ermöglicht Denial of Service und Offenlegung von InformationenDeutsch2024-06-10csaf · cert_bundDE
Ein entfernter, anonymer Angreifer kann eine Schwachstelle in Siemens SIMATIC S7 ausnutzen, um einen Denial-of-Service-Zustand zu erzeugen und Informationen offenzulegen.
- ICSA-24-165-02Siemens SIMATIC S7-200 SMART Devices2024-06-11icsa · cisa_csaf_otUS
SIMATIC S7-200 SMART devices contain an information disclosure vulnerability which leaves the system susceptible to a family of attacks which rely on the use of predictable IP ID sequence numbers as their base method of attack and eventually could allow an attacker to create a denial of service condition. Siemens recommends specific countermeasures for products where fixes are not, or not yet available.
auch bekannt als (4)
Weitere Namen und Kennungen dieser Entität.
quellen
Welche Quellen diesen Datensatz belegen und wann.
Referenzen (6)
Externe Belege — Patches, Meldungen, Analysen.
- https://cert-portal.siemens.com/productcert/html/ssa-481506.htmlcnnvd
- https://cxsecurity.com/cveshow/CVE-2024-35292/cnnvd
- https://nvd.nist.gov/vuln/detail/CVE-2024-35292cnnvd
- https://vigilance.fr/vulnerability/SIMATIC-S7-200-SMART-information-disclosure-via-IP-ID-Sequence-Number-44479cnnvd
- https://cert-portal.siemens.com/productcert/html/ssa-481506.htmlenisa_euvd
- https://cert-portal.siemens.com/productcert/html/ssa-481506.htmlnvd
Angreifer nutzen Schwachstellen wie diese gegen im Internet exponierte Dienste aus. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.
Kostenloser Scan