CVE-2024-33698
criticalPriorität · verfolgen · 0EPSS 0.011 · 64. PerzentilDEEUNLRUUSEPSS · bewertet 2026-10-22
A vulnerability has been identified in Opcenter Quality (All versions < V2406), Opcenter RDnL (All versions < V2410), SIMATIC PCS neo V4.0 (All versions), SIMATIC PCS neo V4.1 (All versions < V4.1 Update 2), SIMATIC PCS neo V5.0 (All versions < V5.0 Update 1), SINEC NMS (All versions), SINEMA Remote Connect Client (All versions < V3.2 SP3), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 5), Totally Integrated Automation Portal (TIA Portal) V19 (All versions < V19 Update 3). Affected products contain a heap-based buffer overflow vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to execute arbitrary code.
Behebungen
Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.
Ein Hersteller-Fix ist verfügbar.
- BehobenOpcenter Qualitysiemens_psirt
Update to V2406 or later version
- BehobenOpcenter RDnLsiemens_psirt
Update to V2410 or later version
https://support.sw.siemens.com/product/297341591/ - BehobenSIMATIC PCS neo V4.1siemens_psirt
Update to V4.1 Update 2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109972354/ - BehobenSIMATIC PCS neo V5.0siemens_psirt
Update to V5.0 Update 1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977244/ - BehobenSINEC NMSsiemens_psirt
Update UMC to V2.15.1.1 or later compatible version https://support.industry.siemens.com/cs/ww/en/view/109987708/
- BehobenSINEMA Remote Connect Clientsiemens_psirt
Update to V3.2 SP3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109976964/ - BehobenTotally Integrated Automation Portal (TIA Portal) V17siemens_psirt
Update to V17 Update 8 or later version
https://support.industry.siemens.com/cs/ww/en/view/109784441/ - BehobenTotally Integrated Automation Portal (TIA Portal) V18siemens_psirt
Update to V18 Update 5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817218/ - BehobenTotally Integrated Automation Portal (TIA Portal) V19siemens_psirt
Update to V19 Update 3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109925643/ - BehobenOpcenter Qualitycisa_csaf_ot
Update to V2406 or later version
- BehobenOpcenter RDnLcisa_csaf_ot
Update to V2410 or later version
https://support.sw.siemens.com/product/297341591/ - BehobenSIMATIC PCS neo V4.1cisa_csaf_ot
Update to V4.1 Update 2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109972354/ - BehobenSIMATIC PCS neo V5.0cisa_csaf_ot
Update to V5.0 Update 1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977244/ - BehobenSINEC NMScisa_csaf_ot
Update UMC to V2.15.1.1 or later compatible version https://support.industry.siemens.com/cs/ww/en/view/109987708/
- BehobenSINEMA Remote Connect Clientcisa_csaf_ot
Update to V3.2 SP3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109976964/ - BehobenTotally Integrated Automation Portal (TIA Portal) V17cisa_csaf_ot
Update to V17 Update 8 or later version
https://support.industry.siemens.com/cs/ww/en/view/109784441/ - BehobenTotally Integrated Automation Portal (TIA Portal) V18cisa_csaf_ot
Update to V18 Update 5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817218/ - BehobenTotally Integrated Automation Portal (TIA Portal) V19cisa_csaf_ot
Update to V19 Update 3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109925643/ - MitigationOpcenter Qualitysiemens_psirt
Filter the ports 4002 and 4004 to only accept connections to/from the IP addresses of machines that run UMC and are part of the UMC network e.g. with an external firewall
- MitigationOpcenter RDnLsiemens_psirt
Filter the ports 4002 and 4004 to only accept connections to/from the IP addresses of machines that run UMC and are part of the UMC network e.g. with an external firewall
- MitigationSIMATIC PCS neo V4.0siemens_psirt
Filter the ports 4002 and 4004 to only accept connections to/from the IP addresses of machines that run UMC and are part of the UMC network e.g. with an external firewall
- MitigationSIMATIC PCS neo V4.1siemens_psirt
Filter the ports 4002 and 4004 to only accept connections to/from the IP addresses of machines that run UMC and are part of the UMC network e.g. with an external firewall
- MitigationSIMATIC PCS neo V5.0siemens_psirt
Filter the ports 4002 and 4004 to only accept connections to/from the IP addresses of machines that run UMC and are part of the UMC network e.g. with an external firewall
- MitigationSINEC NMSsiemens_psirt
Filter the ports 4002 and 4004 to only accept connections to/from the IP addresses of machines that run UMC and are part of the UMC network e.g. with an external firewall
- MitigationSINEMA Remote Connect Clientsiemens_psirt
Filter the ports 4002 and 4004 to only accept connections to/from the IP addresses of machines that run UMC and are part of the UMC network e.g. with an external firewall
- MitigationTotally Integrated Automation Portal (TIA Portal) V16siemens_psirt
Filter the ports 4002 and 4004 to only accept connections to/from the IP addresses of machines that run UMC and are part of the UMC network e.g. with an external firewall
- MitigationTotally Integrated Automation Portal (TIA Portal) V17siemens_psirt
Filter the ports 4002 and 4004 to only accept connections to/from the IP addresses of machines that run UMC and are part of the UMC network e.g. with an external firewall
- MitigationTotally Integrated Automation Portal (TIA Portal) V18siemens_psirt
Filter the ports 4002 and 4004 to only accept connections to/from the IP addresses of machines that run UMC and are part of the UMC network e.g. with an external firewall
- MitigationTotally Integrated Automation Portal (TIA Portal) V19siemens_psirt
Filter the ports 4002 and 4004 to only accept connections to/from the IP addresses of machines that run UMC and are part of the UMC network e.g. with an external firewall
- MitigationOpcenter Qualitycisa_csaf_ot
Filter the ports 4002 and 4004 to only accept connections to/from the IP addresses of machines that run UMC and are part of the UMC network e.g. with an external firewall
- MitigationOpcenter RDnLcisa_csaf_ot
Filter the ports 4002 and 4004 to only accept connections to/from the IP addresses of machines that run UMC and are part of the UMC network e.g. with an external firewall
- MitigationSIMATIC PCS neo V4.0cisa_csaf_ot
Filter the ports 4002 and 4004 to only accept connections to/from the IP addresses of machines that run UMC and are part of the UMC network e.g. with an external firewall
- MitigationSIMATIC PCS neo V4.1cisa_csaf_ot
Filter the ports 4002 and 4004 to only accept connections to/from the IP addresses of machines that run UMC and are part of the UMC network e.g. with an external firewall
- MitigationSIMATIC PCS neo V5.0cisa_csaf_ot
Filter the ports 4002 and 4004 to only accept connections to/from the IP addresses of machines that run UMC and are part of the UMC network e.g. with an external firewall
- MitigationSINEC NMScisa_csaf_ot
Filter the ports 4002 and 4004 to only accept connections to/from the IP addresses of machines that run UMC and are part of the UMC network e.g. with an external firewall
- MitigationSINEMA Remote Connect Clientcisa_csaf_ot
Filter the ports 4002 and 4004 to only accept connections to/from the IP addresses of machines that run UMC and are part of the UMC network e.g. with an external firewall
- MitigationTotally Integrated Automation Portal (TIA Portal) V16cisa_csaf_ot
Filter the ports 4002 and 4004 to only accept connections to/from the IP addresses of machines that run UMC and are part of the UMC network e.g. with an external firewall
- MitigationTotally Integrated Automation Portal (TIA Portal) V17cisa_csaf_ot
Filter the ports 4002 and 4004 to only accept connections to/from the IP addresses of machines that run UMC and are part of the UMC network e.g. with an external firewall
- MitigationTotally Integrated Automation Portal (TIA Portal) V18cisa_csaf_ot
Filter the ports 4002 and 4004 to only accept connections to/from the IP addresses of machines that run UMC and are part of the UMC network e.g. with an external firewall
- MitigationTotally Integrated Automation Portal (TIA Portal) V19cisa_csaf_ot
Filter the ports 4002 and 4004 to only accept connections to/from the IP addresses of machines that run UMC and are part of the UMC network e.g. with an external firewall
- Kein Fix geplantSIMATIC PCS neo V4.0siemens_psirt
Currently no fix is planned
- Kein Fix geplantTotally Integrated Automation Portal (TIA Portal) V16siemens_psirt
Currently no fix is planned
- Kein Fix geplantSIMATIC PCS neo V4.0cisa_csaf_ot
Currently no fix is planned
- Kein Fix geplantTotally Integrated Automation Portal (TIA Portal) V16cisa_csaf_ot
Currently no fix is planned
cvss
Technischer Schweregrad, 0–10. Eine Zeile je Quelle.
Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen⚠ Quellen uneinig · high–critical · 8.1–9.8
SSVC
Eine Handlungsentscheidung — aus Ausnutzung und Auswirkung.
schwächen
Die CWE-Schwächeklassen, zu denen dies gehört.
betroffene Produkte (73)
Betroffene Produkte und Versionsbereiche.
Advisories (4)
Hersteller- und Ökosystem-Meldungen dazu.
- NCSC-2024-0362Kwetsbaarheden verholpen in Siemens productenNL2024-09-10csaf · ncsc_nlNL
Siemens heeft kwetsbaarheden verholpen in diverse producten als Mendix, SICAM, SIMATIC, SINEMA, SINUMERIK en Tecnomatix.
- SSA-039007SSA-039007: Heap-based Buffer Overflow Vulnerability in User Management Component (UMC)2024-09-10csaf · siemens_psirtDE
Siemens User Management Component (UMC) is affected by a heap-based buffer overflow vulnerability which could allow an unauthenticated remote attacker arbitrary code execution. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends specific countermeasures for products where fixes are not, or not yet available.
- WID-SEC-W-2024-2093Siemens TIA Portal: Schwachstelle ermöglicht CodeausführungDeutsch2024-09-09csaf · cert_bundDE
Ein entfernter, anonymer Angreifer kann eine Schwachstelle in Siemens TIA Portal ausnutzen, um beliebigen Programmcode auszuführen.
- ICSA-24-256-03Siemens User Management Component (UMC)2024-09-10icsa · cisa_csaf_otUS
Siemens User Management Component (UMC) is affected by a heap-based buffer overflow vulnerability which could allow an unauthenticated remote attacker arbitrary code execution. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends specific countermeasures for products where fixes are not, or not yet available.
auch bekannt als (4)
Weitere Namen und Kennungen dieser Entität.
quellen
Welche Quellen diesen Datensatz belegen und wann.
Referenzen (6)
Externe Belege — Patches, Meldungen, Analysen.
- https://access.redhat.com/security/cve/cve-2024-33698cnnvd
- https://cert-portal.siemens.com/productcert/html/ssa-039007.htmlcnnvd
- https://cxsecurity.com/cveshow/CVE-2024-33698/cnnvd
- https://nvd.nist.gov/vuln/detail/CVE-2024-33698cnnvd
- https://cert-portal.siemens.com/productcert/html/ssa-039007.htmlenisa_euvd
- https://cert-portal.siemens.com/productcert/html/ssa-039007.htmlnvd
Angreifer nutzen Schwachstellen wie diese gegen im Internet exponierte Dienste aus. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.
Kostenloser Scan