CVE-2024-33577

highPriorität · verfolgen · 0EPSS 0.002 · 14. PerzentilDEEUNLRUUS
grimoire priorityP2 · Scheduled
Exploitable?
—
no known exploitation
Likely / severe?
0.23% (14th) EPSS
CVSS 7.8 · high
Is it mine?
15 products
Prüfe deine Angriffsfläche
Who says so?
7 sources
cnnvd · enisa_euvd · fstec_bdu · cisa_csaf_ot

EPSS · bewertet 2026-10-27

A vulnerability has been identified in Simcenter Femap (All versions < V2406). The affected applications contain a stack overflow vulnerability while parsing specially strings as argument for one of the application binaries. This could allow an attacker to execute code in the context of the current process.

01

Behebungen

Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.

Ein Hersteller-Fix ist verfügbar.

02

cvss

Technischer Schweregrad, 0–10. Eine Zeile je Quelle.

7.8
010

Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen⚠ Quellen uneinig · medium–high · 4.4–7.8

v3.17.8highCVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:Hsecondary · productcert@siemens.com DEAusnutzbarkeit 1.8 · Auswirkung 5.9
v3.17.8highCVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:Hsecondary · Siemens ProductCERT DE
v3.17.8highAV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:Hsecondary · FSTEC (BDU) RU
v3.17.8highCVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:Hsecondary · CISA US
v4.07.3highCVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:Xsecondary · productcert@siemens.com DE
v4.07.3highCVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:Nsecondary · ENISA EU
v4.04.4mediumCVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:U/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:Xsecondary · CVSS-BT (t0sche)
03

SSVC

Eine Handlungsentscheidung — aus Ausnutzung und Auswirkung.

Exploitation: none · Automatable: no · Technical Impact: totalcoordinatorcisa_ssvcUS
04

schwächen

Die CWE-Schwächeklassen, zu denen dies gehört.

05

betroffene Produkte (15)

Betroffene Produkte und Versionsbereiche.

06

Advisories (5)

Hersteller- und Ökosystem-Meldungen dazu.

  • NCSC-2024-0282Kwetsbaarheden verholpen in Siemens ProductenNL2024-07-09csaf · ncsc_nlNL

    Siemens heeft kwetsbaarheden verholpen in diverse producten als Mendix, RUGGEDOM, SIMATIC, SINEMA, SIPROTEC en de Engineering Platforms voor diverse systemen.

  • SSA-064222SSA-064222: Multiple File Parsing Vulnerabilities in Simcenter Femap before V24062024-07-09csaf · siemens_psirtDE

    Simcenter Femap contains multiple file parsing vulnerabilities that could be triggered when the application reads files in IGS, BDF or BMP file formats. If a user is tricked to open a malicious file with any of the affected products, this could lead the application to crash or potentially lead to arbitrary code execution. Siemens has released a new version for Simcenter Femap and recommends to update to the latest version.

  • SSA-258494SSA-258494: Stack Overflow Vulnerability in Simcenter Nastran before 2406.902024-05-14csaf · siemens_psirtDE

    Simcenter Nastran is affected by a stack overflow vulnerability that could be triggered when an application binary reads arbitrary string as a file argument. If a user is tricked to run one of the impacted application binary with a malicious string, an attacker could leverage the vulnerability to perform remote code execution in the context of the current process. Siemens has released a new version for Simcenter Nastran 2406 and recommends to update to the latest version. Siemens recommends countermeasures for products where fixes are not, or not yet available.

  • ICSA-24-137-05Siemens Simcenter Nastran2024-05-14icsa · cisa_csaf_otUS

    Simcenter Nastran is affected by a stack overflow vulnerability that could be triggered when an application binary reads arbitrary string as a file argument. If a user is tricked to run one of the impacted application binary with a malicious string, an attacker could leverage the vulnerability to perform remote code execution in the context of the current process. Siemens has released a new version for Simcenter Nastran 2406 and recommends to update to the latest version. Siemens recommends countermeasures for products where fixes are not, or not yet available.

  • ICSA-24-193-04Siemens Simcenter Femap2024-07-09icsa · cisa_csaf_otUS

    Simcenter Femap contains multiple file parsing vulnerabilities that could be triggered when the application reads files in IGS, BDF or BMP file formats. If a user is tricked to open a malicious file with any of the affected products, this could lead the application to crash or potentially lead to arbitrary code execution. Siemens has released a new version for Simcenter Femap and recommends to update to the latest version.

07

auch bekannt als (5)

Weitere Namen und Kennungen dieser Entität.

08

quellen

Welche Quellen diesen Datensatz belegen und wann.

09

Referenzen (8)

Externe Belege — Patches, Meldungen, Analysen.

scry

Angreifer nutzen Schwachstellen wie diese gegen im Internet exponierte Dienste aus. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.

Kostenloser Scan