CVE-2024-33500

mediumPriorität · verfolgen · 0EPSS 0.003 · 22. PerzentilDEEUNLRUUS
grimoire priorityP3 · Track
Exploitable?
—
no known exploitation
Likely / severe?
0.30% (22nd) EPSS
CVSS 5.9 · medium
Is it mine?
15 products
Prüfe deine Angriffsfläche
Who says so?
6 sources
cnnvd · enisa_euvd · fstec_bdu · cisa_csaf_ot

EPSS · bewertet 2026-10-27

A vulnerability has been identified in Mendix Applications using Mendix 10 (All versions < V10.11.0), Mendix Applications using Mendix 10 (V10.6) (All versions < V10.6.9), Mendix Applications using Mendix 9 (All versions >= V9.3.0 < V9.24.22). Affected applications could allow users with the capability to manage a role to elevate the access rights of users with that role. Successful exploitation requires to guess the id of a target role which contains the elevated access rights.

01

Behebungen

Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.

Ein Hersteller-Fix ist verfügbar.

  • BehobenMendix Applications using Mendix 10siemens_psirt

    Update to V10.11.0 or later version

  • BehobenMendix Applications using Mendix 10 (V10.6)siemens_psirt

    Update to V10.6.9 or later version

  • BehobenMendix Applications using Mendix 9siemens_psirt

    Update to V9.24.22 or later version

  • BehobenMendix Applications using Mendix 10cisa_csaf_ot

    Update to V10.11.0 or later version

  • BehobenMendix Applications using Mendix 10 (V10.6)cisa_csaf_ot

    Update to V10.6.9 or later version

  • BehobenMendix Applications using Mendix 9cisa_csaf_ot

    Update to V9.24.22 or later version

  • MitigationMendix Applications using Mendix 10siemens_psirt

    Set the runtime setting StrictReferenceChecks to false; note however, that this comes at the price of making the reference checks less secure

  • MitigationMendix Applications using Mendix 10 (V10.6)siemens_psirt

    Set the runtime setting StrictReferenceChecks to false; note however, that this comes at the price of making the reference checks less secure

  • MitigationMendix Applications using Mendix 9siemens_psirt

    Set the runtime setting StrictReferenceChecks to false; note however, that this comes at the price of making the reference checks less secure

  • MitigationMendix Applications using Mendix 10cisa_csaf_ot

    Set the runtime setting StrictReferenceChecks to false; note however, that this comes at the price of making the reference checks less secure

  • MitigationMendix Applications using Mendix 10 (V10.6)cisa_csaf_ot

    Set the runtime setting StrictReferenceChecks to false; note however, that this comes at the price of making the reference checks less secure

  • MitigationMendix Applications using Mendix 9cisa_csaf_ot

    Set the runtime setting StrictReferenceChecks to false; note however, that this comes at the price of making the reference checks less secure

02

cvss

Technischer Schweregrad, 0–10. Eine Zeile je Quelle.

7.4
010

Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen⚠ Quellen uneinig · medium–high · 4.5–7.4

v3.15.9mediumCVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:Nsecondary · productcert@siemens.com DEAusnutzbarkeit 0.7 · Auswirkung 5.2
v3.15.9mediumCVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:Nsecondary · Siemens ProductCERT DE
v3.15.9mediumAV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:Nsecondary · FSTEC (BDU) RU
v3.15.9mediumCVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:Nsecondary · CISA US
v4.07.4highCVSS:4.0/AV:N/AC:L/AT:P/PR:H/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:Xsecondary · productcert@siemens.com DE
v4.07.4highCVSS:4.0/AV:N/AC:L/AT:P/PR:H/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:Nsecondary · ENISA EU
v4.04.5mediumCVSS:4.0/AV:N/AC:L/AT:P/PR:H/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N/E:U/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:Xsecondary · CVSS-BT (t0sche)
03

SSVC

Eine Handlungsentscheidung — aus Ausnutzung und Auswirkung.

Exploitation: none · Automatable: no · Technical Impact: totalcoordinatorcisa_ssvcUS
04

schwächen

Die CWE-Schwächeklassen, zu denen dies gehört.

05

betroffene Produkte (15)

Betroffene Produkte und Versionsbereiche.

06

Advisories (3)

Hersteller- und Ökosystem-Meldungen dazu.

  • NCSC-2024-0246Kwetsbaarheden verholpen in Siemens productenNL2024-06-11csaf · ncsc_nlNL

    Siemens heeft kwetsbaarheden verholpen in diverse producten, zoals SCALANCE, SICAM, Tecnomatix, SITOP en PowerSys.

  • SSA-540640SSA-540640: Improper Privilege Management Vulnerability in Mendix Runtime2024-06-11csaf · siemens_psirtDE

    Apps built with Mendix Runtime >= V9.3 could allow users with the capability to manage a role to elevate the access rights of users with that role. Successful exploitation requires to guess the id of a target role which contains the elevated access rights. Siemens has released new versions for the affected products and recommends to update to the latest versions.

  • ICSA-24-165-01Siemens Mendix Applications2024-06-11icsa · cisa_csaf_otUS

    Apps built with Mendix Runtime >= V9.3 could allow users with the capability to manage a role to elevate the access rights of users with that role. Successful exploitation requires to guess the id of a target role which contains the elevated access rights. Siemens has released new versions for the affected products and recommends to update to the latest versions.

07

auch bekannt als (6)

Weitere Namen und Kennungen dieser Entität.

08

quellen

Welche Quellen diesen Datensatz belegen und wann.

09

Referenzen (5)

Externe Belege — Patches, Meldungen, Analysen.

scry

Angreifer nutzen Schwachstellen wie diese gegen im Internet exponierte Dienste aus. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.

Kostenloser Scan