CVE-2024-2004
mediumPriorität · verfolgen · 1OT-Risiko · erhöhtEPSS 0.017 · 77. PerzentilDEEUNLRUUSEPSS · bewertet 2026-10-27
When a protocol selection parameter option disables all protocols without adding any then the default set of protocols would remain in the allowed set due to an error in the logic for removing protocols. The below command would perform a request to curl.se with a plaintext protocol which has been explicitly disabled. curl --proto -all,-http http://curl.se The flaw is only present if the set of selected protocols disables the entire set of available protocols, in itself a command with no practical use and therefore unlikely to be encountered in real situations. The curl security team has thus assessed this to be low severity bug.
Behebungen
Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.
Ein Hersteller-Fix ist verfügbar.
- BehobenSINEC NMSsiemens_psirt
Update to V3.0 SP1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109974917/ - BehobenSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0)siemens_psirt
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AC0)siemens_psirt
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AB0)siemens_psirt
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AC0)siemens_psirt
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1518-4 PN/DP MFP (6AG1518-4AX00-4AC0)siemens_psirt
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSINEMA Remote Connect Clientsiemens_psirt
Update to V3.2 SP2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109974084/ - BehobenSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0)cisa_csaf_ot
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AC0)cisa_csaf_ot
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AB0)cisa_csaf_ot
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AC0)cisa_csaf_ot
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1518-4 PN/DP MFP (6AG1518-4AX00-4AC0)cisa_csaf_ot
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSINEMA Remote Connect Clientcisa_csaf_ot
Update to V3.2 SP2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109974084/ - BehobenSINEC NMScisa_csaf_ot
Update to V3.0 SP1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109974917/ - MitigationSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0)cisa_csaf_ot
Only build and run applications from trusted sources.
- MitigationSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AC0)cisa_csaf_ot
Only build and run applications from trusted sources.
- MitigationSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AB0)cisa_csaf_ot
Only build and run applications from trusted sources.
- MitigationSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AC0)cisa_csaf_ot
Only build and run applications from trusted sources.
- MitigationSIPLUS S7-1500 CPU 1518-4 PN/DP MFP (6AG1518-4AX00-4AC0)cisa_csaf_ot
Only build and run applications from trusted sources.
cvss
Technischer Schweregrad, 0–10. Eine Zeile je Quelle.
Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen⚠ Quellen uneinig · low–medium · 3.2–5.3
SSVC
Eine Handlungsentscheidung — aus Ausnutzung und Auswirkung.
schwächen
Die CWE-Schwächeklassen, zu denen dies gehört.
betroffene Produkte (98)
Betroffene Produkte und Versionsbereiche.
- NetApp ActiveIQ Unified Manager for VMware vSpherealle Versionencert_bundDEcpe:/a:netapp:active_iq_unified_manager:for_vmware_vsphere
Advisories (14)
Hersteller- und Ökosystem-Meldungen dazu.
- NCSC-2024-0320Kwetsbaarheden verholpen in Apple MacOSNL2024-07-30csaf · ncsc_nlNL
Apple heeft kwetsbaarheden verholpen in MacOS.
- NCSC-2024-0339Kwetsbaarheden verholpen in Microsoft MarinerNL2024-08-13csaf · ncsc_nlNL
Microsoft heeft kwetsbaarheden verholpen in Mariner (Azure Linux).
- NCSC-2024-0362Kwetsbaarheden verholpen in Siemens productenNL2024-09-10csaf · ncsc_nlNL
Siemens heeft kwetsbaarheden verholpen in diverse producten als Mendix, SICAM, SIMATIC, SINEMA, SINUMERIK en Tecnomatix.
- NCSC-2024-0433Kwetsbaarheden verholpen in Siemens productenNL2024-11-12csaf · ncsc_nlNL
Siemens heeft kwetsbaarheden verholpen in diverse producten als Mendix, RUGGEDCOM, SCALANCE, SIMATIC en SINEC.
- SSA-331112SSA-331112: Multiple Vulnerabilities in SINEC NMS Before V3.0 SP12024-11-12csaf · siemens_psirtDE
SINEC NMS before V3.0 SP1 is affected by multiple vulnerabilities. Siemens has released a new version for SINEC NMS and recommends to update to the latest version.
- SSA-398330SSA-398330: Vulnerabilities in the additional GNU/Linux subsystem of the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP >= V3.1.0 and < V3.1.52023-12-12csaf · siemens_psirtDE
Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the firmware version >= V3.1.0 and < V3.1.5 for the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP (incl. SIPLUS variant). These GNU/Linux vulnerabilities have been externally identified. Siemens has released new versions for the affected products and recommends to update to the latest versions. SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP >= V3.1.0 and < V3.1.5 are no longer maintained and there won't be any update to the CVE list anymore. Please update to the latest version. Note: This SSA advises vulnerabilities for firmware version V3.1 only; for versions < V3.1 refer to Siemens Security Bulletin SSB-439005 (https://cert-portal.siemens.com/productcert/html/ssb-439005.html).
- SSA-417159SSA-417159: Multiple Vulnerabilities in SINEMA Remote Connect Client Before V3.2 SP22024-09-10csaf · siemens_psirtDE
SINEMA Remote Connect Client before V3.2 SP2 is affected by multiple vulnerabilities. Siemens has released a new version for SINEMA Remote Connect Client and recommends to update to the latest version.
- WID-SEC-W-2024-0726cURL: Mehrere SchwachstellenDeutsch2024-03-26csaf · cert_bundDE
Ein entfernter, authentisierter Angreifer kann mehrere Schwachstellen in cURL ausnutzen, um einen Denial of Service Angriff durchzuführen, Informationen offenzulegen oder um Sicherheitsmaßnahmen zu umgehen.
- WID-SEC-W-2024-1725Apple macOS: Mehrere SchwachstellenDeutsch2024-07-29csaf · cert_bundDE
Ein entfernter, anonymer Angreifer kann mehrere Schwachstellen in Apple macOS ausnutzen, um seine Privilegien zu erhöhen, beliebigen Code mit Administratorrechten auszuführen, einen Denial-of-Service-Zustand zu erzeugen, Daten zu modifizieren, den Benutzer zu täuschen, Sicherheitsmaßnahmen zu umgehen und vertrauliche Informationen offenzulegen.
- WID-SEC-W-2025-0225Dell PowerProtect Data Domain: Mehrere SchwachstellenDeutsch2025-01-30csaf · cert_bundDE
Ein Angreifer kann mehrere Schwachstellen in Dell PowerProtect Data Domain ausnutzen, um erhöhte Rechte zu erlangen, einen Denial-of-Service-Zustand herbeizuführen und einen nicht näher spezifizierten Angriff durchzuführen.
- ICSA-23-348-10Siemens SIMATIC S7-15002023-12-12icsa · cisa_csaf_otUS
Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the firmware version >= V3.1.0 and < V3.1.5 for the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP (incl. SIPLUS variant). These GNU/Linux vulnerabilities have been externally identified. Siemens has released new versions for the affected products and recommends to update to the latest versions. Note: This SSA advises vulnerabilities for firmware version V3.1 only; for versions < V3.1 refer to Siemens Security Bulletin SSB-439005 ( https://cert-portal.siemens.com/productcert/html/ssb-439005.html).
- ICSA-24-256-10Siemens SINEMA2024-09-10icsa · cisa_csaf_otUS
SINEMA Remote Connect Client before V3.2 SP2 is affected by multiple vulnerabilities. Siemens has released a new version for SINEMA Remote Connect Client and recommends to update to the latest version.
- ICSA-24-319-04Siemens SINEC NMS2024-11-12icsa · cisa_csaf_otUS
SINEC NMS before V3.0 SP1 is affected by multiple vulnerabilities. Siemens has released a new version for SINEC NMS and recommends to update to the latest version.
- CURL-CVE-2024-2004Usage of disabled protocol2024-03-27vendor · osvUS
When a protocol selection parameter option disables all protocols without adding any then the default set of protocols would remain in the allowed set due to an error in the logic for removing protocols. The below command would perform a request to curl.se with a plaintext protocol which has been explicitly disabled. curl --proto -all,-http http://curl.se The flaw is only present if the set of selected protocols disables the entire set of available protocols, in itself a command with no practical use and therefore unlikely to be encountered in real situations. The curl security team has thus assessed this to be low severity bug.
auch bekannt als (4)
Weitere Namen und Kennungen dieser Entität.
quellen
Welche Quellen diesen Datensatz belegen und wann.
Referenzen (36)
Externe Belege — Patches, Meldungen, Analysen.
- https://access.redhat.com/security/cve/cve-2024-2004cnnvd
- https://curl.se/docs/CVE-2024-2004.htmlcnnvd
- https://curl.se/docs/CVE-2024-2004.jsoncnnvd
- https://cxsecurity.com/cveshow/CVE-2024-2004/cnnvd
- https://github.com/curl/curl/releases/tag/curl-8_7_1Patchcnnvd
- https://hackerone.com/reports/2384833cnnvd
- https://support.apple.com/en-us/HT214118cnnvd
- http://seclists.org/fulldisclosure/2024/Jul/18enisa_euvd
Angreifer nutzen Schwachstellen wie diese gegen im Internet exponierte Dienste aus. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.
Kostenloser Scan