CWE-770: Allocation of Resources Without Limits or Throttling vulnerability exists that could cause denial of service of the OPC UA communication platform when a large number of OPC UA requests are sent to the platform.

01

Behebungen

Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.

Ein Hersteller-Fix ist verfügbar.

  • BehobenEcoStruxure OPC UA Server Expertcisa_csaf_ot

    Version SV2.01 SP3 of EcoStruxure OPC UA Server Expert includes a fix for this vulnerability and is available for download here: https://www.se.com/ww/en/product-range/66388-ecostruxure-opc-ua-server-expert/#software-and-firmware

    https://www.se.com/ww/en/product-range/66388-ecostruxure-opc-ua-server-expert/#software-and-firmware
  • MitigationEcoStruxure Modicon Communication Servercisa_csaf_ot

    Schneider Electric is establishing a remediation plan for all future versions of EcoStruxure Modicon Communication Server that will include a fix for this vulnerability. We will update this document when the remediation is available. Until then, customers should immediately apply the following mitigations to reduce the risk of exploit: * Set the “Security Policy” to Basic256-Sha256 (default value indicated by unchecked “Security Policy” setting) used for secure communication between OPC UA client & server based on OPC UA standard. * Ensure that the “Anonymous user token” setting remains unchecked (unchecked by default) to prevent anonymous authentication. * Set “User authentication” setting (checked by default) used to authenticate & authorize OPC UA client. * Set “X509 user token” setting (checked by default) used to authenticate & authorize OPC UA client. For more details, refer to “EcoStruxure Modicon Server User Guide” chapter “Security Settings”: https://www.se.com/fr/fr/download/document/EIO0000004083/ * Follow workstation, network and site-hardening guidelines in the “Recommended Cybersecurity Best Practices”: https://www.se.com/ww/en/download/document/7EN52-0390/

    https://www.se.com/fr/fr/download/document/EIO0000004083/
  • MitigationEcoStruxure OPC UA Server Expertcisa_csaf_ot

    If customers choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit: * Set the “Security Policy” to Basic256-Sha256 (default value indicated by unchecked “Security Policy” setting) used for secure communication between OPC UA client & server based on OPC UA standard. * Ensure that the “Anonymous user token” setting remains unchecked (unchecked by default) to prevent anonymous authentication. * Set “User authentication” setting (checked by default) used to authenticate & authorize OPC UA client. * Set “X509 user token” setting (checked by default) used to authenticate & authorize OPC UA client. For more details, refer to “EcoStruxure OPC UA Server Expert User Guide” chapter “Security Management”: https://www.se.com/ww/en/download/document/MFR53158/ * Follow workstation, network and site-hardening guidelines in the “Recommended Cybersecurity Best Practices”: https://www.se.com/ww/en/download/document/7EN52-0390/

    https://www.se.com/ww/en/download/document/MFR53158/
02

cvss

Technischer Schweregrad, 0–10. Eine Zeile je Quelle.

8.2
010

Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen⚠ Quellen uneinig · medium–high · 4.6–8.2

v3.17.5highCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:Hsecondary · CISA US
v3.17.5highAV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:Hsecondary · FSTEC (BDU) RU
v4.08.2highCVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:Xsecondary · cybersecurity@se.com
v4.04.6mediumCVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:U/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:Xsecondary · CVSS-BT (t0sche)
03

SSVC

Eine Handlungsentscheidung — aus Ausnutzung und Auswirkung.

Trackcoordinatorcisa_ssvcUS
04

schwächen

Die CWE-Schwächeklassen, zu denen dies gehört.

05

betroffene Produkte (7)

Betroffene Produkte und Versionsbereiche.

06

Advisories (1)

Hersteller- und Ökosystem-Meldungen dazu.

  • ICSA-25-301-01Schneider Electric EcoStruxure2025-10-14icsa · cisa_csaf_otUS

    Schneider Electric is aware of a vulnerability in its EcoStruxure OPC UA Server Expert product(s). The [EcoStruxure OPC UA Server Expert product(s)](https://www.se.com/ww/en/product-country-selector/?pageType=product-range&sourceId=66388#overview) is a state-of-the-art OPC UA communication platform linking Modicon industrial equipment and PLCs to the Industrial Internet of Things (IIoT). [EcoStruxure Modicon Communication Server](https://www.se.com/ww/en/download/document/ES_MCS_2.01_SP2/) is a communication platform seamlessly linking Modicon PLCs to Aveva System Platform by using the OPC UA protocol with the help of OPC UA Server. Failure to apply the fix / mitigation provided below may risk denial of service of EcoStruxureTM OPCUA Server Expert, which could result in the loss of real-time process data from Modicon Controller.

07

auch bekannt als (1)

Weitere Namen und Kennungen dieser Entität.

08

quellen

Welche Quellen diesen Datensatz belegen und wann.

veröffentlicht 2026-09-01geändert 2026-10-27
09

Referenzen (1) nvd

Externe Belege — Patches, Meldungen, Analysen.

scry

Angreifer nutzen Schwachstellen wie diese gegen im Internet exponierte Dienste aus. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.

Kostenloser Scan