CVE-2023-5363
highPriorität · verfolgen · 31EPSS 0.033 · 89. PerzentilDEEUNLRUUSEPSS · bewertet 2026-10-23
Issue summary: A bug has been identified in the processing of key and initialisation vector (IV) lengths. This can lead to potential truncation or overruns during the initialisation of some symmetric ciphers. Impact summary: A truncation in the IV can result in non-uniqueness, which could result in loss of confidentiality for some cipher modes. When calling EVP_EncryptInit_ex2(), EVP_DecryptInit_ex2() or EVP_CipherInit_ex2() the provided OSSL_PARAM array is processed after the key and IV have been established. Any alterations to the key length, via the "keylen" parameter or the IV length, via the "ivlen" parameter, within the OSSL_PARAM array will not take effect as intended, potentially causing truncation or overreading of these values. The following ciphers and cipher modes are impacted: RC2, RC4, RC5, CCM, GCM and OCB. For the CCM, GCM and OCB cipher modes, truncation of the IV can result in loss of confidentiality. For example, when following NIST's SP 800-38D section 8.2.1 guidance for constructing a deterministic IV for AES in GCM mode, truncation of the counter portion could lead to IV reuse. Both truncations and overruns of the key and overruns of the IV will produce incorrect results and could, in some cases, trigger a memory exception. However, these issues are not currently assessed as security critical. Changing the key and/or IV lengths is not considered to be a common operation and the vulnerable API was recently introduced. Furthermore it is likely that application developers will have spotted this problem during testing since decryption would fail unless both peers in the communication were similarly vulnerable. For these reasons we expect the probability of an application being vulnerable to this to be quite low. However if an application is vulnerable then this issue is considered very serious. For these reasons we have assessed this issue as Moderate severity overall. The OpenSSL SSL/TLS implementation is not affected by this issue. The OpenSSL 3.0 and 3.1 FIPS providers are not affected by this because the issue lies outside of the FIPS provider boundary. OpenSSL 3.1 and 3.0 are vulnerable to this issue.
Behebungen
Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.
Ein Hersteller-Fix ist verfügbar.
- BehobenSIMATIC RTLS Locating Manager (6GT2780-0DA00)siemens_psirt
Update to V3.0.1.1 or later version The update is available from Siemens Online Software Delivery (OSD).
- BehobenSIMATIC RTLS Locating Manager (6GT2780-0DA10)siemens_psirt
Update to V3.0.1.1 or later version The update is available from Siemens Online Software Delivery (OSD).
- BehobenSIMATIC RTLS Locating Manager (6GT2780-0DA20)siemens_psirt
Update to V3.0.1.1 or later version The update is available from Siemens Online Software Delivery (OSD).
- BehobenSIMATIC RTLS Locating Manager (6GT2780-0DA30)siemens_psirt
Update to V3.0.1.1 or later version The update is available from Siemens Online Software Delivery (OSD).
- BehobenSIMATIC RTLS Locating Manager (6GT2780-1EA10)siemens_psirt
Update to V3.0.1.1 or later version The update is available from Siemens Online Software Delivery (OSD).
- BehobenSIMATIC RTLS Locating Manager (6GT2780-1EA20)siemens_psirt
Update to V3.0.1.1 or later version The update is available from Siemens Online Software Delivery (OSD).
- BehobenSIMATIC RTLS Locating Manager (6GT2780-1EA30)siemens_psirt
Update to V3.0.1.1 or later version The update is available from Siemens Online Software Delivery (OSD).
- BehobenSIDIS Primesiemens_psirt
Update to V4.0.700 or later version
- BehobenSINEC NMSsiemens_psirt
Update to V3.0 SP1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109974917/ - BehobenSCALANCE WAB762-1 (6GK5762-1AJ00-6AA0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WAM763-1 (6GK5763-1AL00-7DA0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WAM763-1 (ME) (6GK5763-1AL00-7DC0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WAM763-1 (US) (6GK5763-1AL00-7DB0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WAM766-1 (6GK5766-1GE00-7DA0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WAM766-1 (ME) (6GK5766-1GE00-7DC0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WAM766-1 EEC (ME) (6GK5766-1GE00-7TC0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WUB762-1 (6GK5762-1AJ00-1AA0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WUB762-1 iFeatures (6GK5762-1AJ00-2AA0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WUM763-1 (6GK5763-1AL00-3AA0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WUM763-1 (6GK5763-1AL00-3DA0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WUM763-1 (US) (6GK5763-1AL00-3AB0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WUM763-1 (US) (6GK5763-1AL00-3DB0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WUM766-1 (6GK5766-1GE00-3DA0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WUM766-1 (ME) (6GK5766-1GE00-3DC0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - Behobenphoenix_contact_psirt
Update to the latest 2024.0.6 LTS Firmware Release. PHOENIX CONTACT recommends to always use an up-to-date version of the PLCnext Engineer.
- BehobenSIMATIC RTLS Locating Manager (6GT2780-0DA00)cisa_csaf_ot
Update to V3.0.1.1 or later version The update is available from Siemens Online Software Delivery (OSD).
- BehobenSIMATIC RTLS Locating Manager (6GT2780-0DA10)cisa_csaf_ot
Update to V3.0.1.1 or later version The update is available from Siemens Online Software Delivery (OSD).
- BehobenSIMATIC RTLS Locating Manager (6GT2780-0DA20)cisa_csaf_ot
Update to V3.0.1.1 or later version The update is available from Siemens Online Software Delivery (OSD).
- BehobenSIMATIC RTLS Locating Manager (6GT2780-0DA30)cisa_csaf_ot
Update to V3.0.1.1 or later version The update is available from Siemens Online Software Delivery (OSD).
- BehobenSIMATIC RTLS Locating Manager (6GT2780-1EA10)cisa_csaf_ot
Update to V3.0.1.1 or later version The update is available from Siemens Online Software Delivery (OSD).
- BehobenSIMATIC RTLS Locating Manager (6GT2780-1EA20)cisa_csaf_ot
Update to V3.0.1.1 or later version The update is available from Siemens Online Software Delivery (OSD).
- BehobenSIMATIC RTLS Locating Manager (6GT2780-1EA30)cisa_csaf_ot
Update to V3.0.1.1 or later version The update is available from Siemens Online Software Delivery (OSD).
- BehobenSINEC NMScisa_csaf_ot
Update to V3.0 SP1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109974917/ - BehobenSCALANCE WAB762-1 (6GK5762-1AJ00-6AA0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WAM763-1 (6GK5763-1AL00-7DA0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WAM763-1 (ME) (6GK5763-1AL00-7DC0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WAM763-1 (US) (6GK5763-1AL00-7DB0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WAM766-1 (6GK5766-1GE00-7DA0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WAM766-1 (ME) (6GK5766-1GE00-7DC0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WAM766-1 EEC (ME) (6GK5766-1GE00-7TC0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WUB762-1 (6GK5762-1AJ00-1AA0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WUB762-1 iFeatures (6GK5762-1AJ00-2AA0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WUM763-1 (6GK5763-1AL00-3AA0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WUM763-1 (6GK5763-1AL00-3DA0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WUM763-1 (US) (6GK5763-1AL00-3AB0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WUM763-1 (US) (6GK5763-1AL00-3DB0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WUM766-1 (6GK5766-1GE00-3DA0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WUM766-1 (ME) (6GK5766-1GE00-3DC0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSIDIS Primecisa_csaf_ot
Update to V4.0.700 or later version
- MitigationSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0)siemens_psirt
Limit access to the interactive shell of the additional GNU/Linux subssytem to trusted personnel only.
- MitigationSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AC0)siemens_psirt
Limit access to the interactive shell of the additional GNU/Linux subssytem to trusted personnel only.
- MitigationSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AB0)siemens_psirt
Limit access to the interactive shell of the additional GNU/Linux subssytem to trusted personnel only.
- MitigationSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AC0)siemens_psirt
Limit access to the interactive shell of the additional GNU/Linux subssytem to trusted personnel only.
- MitigationSIPLUS S7-1500 CPU 1518-4 PN/DP MFP (6AG1518-4AX00-4AC0)siemens_psirt
Limit access to the interactive shell of the additional GNU/Linux subssytem to trusted personnel only.
- MitigationSIMATIC RTLS Locating Manager (6GT2780-0DA00)siemens_psirt
Apply security hardening of the Windows Server, where the RTLS Locating Manager is installed on, in accordance with your corporate security policies or up-to-date hardening guidelines
- MitigationSIMATIC RTLS Locating Manager (6GT2780-0DA10)siemens_psirt
Apply security hardening of the Windows Server, where the RTLS Locating Manager is installed on, in accordance with your corporate security policies or up-to-date hardening guidelines
- MitigationSIMATIC RTLS Locating Manager (6GT2780-0DA20)siemens_psirt
Apply security hardening of the Windows Server, where the RTLS Locating Manager is installed on, in accordance with your corporate security policies or up-to-date hardening guidelines
- MitigationSIMATIC RTLS Locating Manager (6GT2780-0DA30)siemens_psirt
Apply security hardening of the Windows Server, where the RTLS Locating Manager is installed on, in accordance with your corporate security policies or up-to-date hardening guidelines
- MitigationSIMATIC RTLS Locating Manager (6GT2780-1EA10)siemens_psirt
Apply security hardening of the Windows Server, where the RTLS Locating Manager is installed on, in accordance with your corporate security policies or up-to-date hardening guidelines
- MitigationSIMATIC RTLS Locating Manager (6GT2780-1EA20)siemens_psirt
Apply security hardening of the Windows Server, where the RTLS Locating Manager is installed on, in accordance with your corporate security policies or up-to-date hardening guidelines
- MitigationSIMATIC RTLS Locating Manager (6GT2780-1EA30)siemens_psirt
Apply security hardening of the Windows Server, where the RTLS Locating Manager is installed on, in accordance with your corporate security policies or up-to-date hardening guidelines
- MitigationSIMATIC RTLS Locating Manager (6GT2780-0DA00)cisa_csaf_ot
Apply security hardening of the Windows Server, where the RTLS Locating Manager is installed on, in accordance with your corporate security policies or up-to-date hardening guidelines
- MitigationSIMATIC RTLS Locating Manager (6GT2780-0DA10)cisa_csaf_ot
Apply security hardening of the Windows Server, where the RTLS Locating Manager is installed on, in accordance with your corporate security policies or up-to-date hardening guidelines
- MitigationSIMATIC RTLS Locating Manager (6GT2780-0DA20)cisa_csaf_ot
Apply security hardening of the Windows Server, where the RTLS Locating Manager is installed on, in accordance with your corporate security policies or up-to-date hardening guidelines
- MitigationSIMATIC RTLS Locating Manager (6GT2780-0DA30)cisa_csaf_ot
Apply security hardening of the Windows Server, where the RTLS Locating Manager is installed on, in accordance with your corporate security policies or up-to-date hardening guidelines
- MitigationSIMATIC RTLS Locating Manager (6GT2780-1EA10)cisa_csaf_ot
Apply security hardening of the Windows Server, where the RTLS Locating Manager is installed on, in accordance with your corporate security policies or up-to-date hardening guidelines
- MitigationSIMATIC RTLS Locating Manager (6GT2780-1EA20)cisa_csaf_ot
Apply security hardening of the Windows Server, where the RTLS Locating Manager is installed on, in accordance with your corporate security policies or up-to-date hardening guidelines
- MitigationSIMATIC RTLS Locating Manager (6GT2780-1EA30)cisa_csaf_ot
Apply security hardening of the Windows Server, where the RTLS Locating Manager is installed on, in accordance with your corporate security policies or up-to-date hardening guidelines
- MitigationSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0)cisa_csaf_ot
Limit access to the interactive shell of the additional GNU/Linux subssytem to trusted personnel only.
- MitigationSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AC0)cisa_csaf_ot
Limit access to the interactive shell of the additional GNU/Linux subssytem to trusted personnel only.
- MitigationSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AB0)cisa_csaf_ot
Limit access to the interactive shell of the additional GNU/Linux subssytem to trusted personnel only.
- MitigationSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AC0)cisa_csaf_ot
Limit access to the interactive shell of the additional GNU/Linux subssytem to trusted personnel only.
- MitigationSIPLUS S7-1500 CPU 1518-4 PN/DP MFP (6AG1518-4AX00-4AC0)cisa_csaf_ot
Limit access to the interactive shell of the additional GNU/Linux subssytem to trusted personnel only.
- Kein Fix verfügbarSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0)siemens_psirt
Currently no fix is available
- Kein Fix verfügbarSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AC0)siemens_psirt
Currently no fix is available
- Kein Fix verfügbarSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AB0)siemens_psirt
Currently no fix is available
- Kein Fix verfügbarSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AC0)siemens_psirt
Currently no fix is available
- Kein Fix verfügbarSIPLUS S7-1500 CPU 1518-4 PN/DP MFP (6AG1518-4AX00-4AC0)siemens_psirt
Currently no fix is available
- Kein Fix verfügbarSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0)cisa_csaf_ot
Currently no fix is available
- Kein Fix verfügbarSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AC0)cisa_csaf_ot
Currently no fix is available
- Kein Fix verfügbarSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AB0)cisa_csaf_ot
Currently no fix is available
- Kein Fix verfügbarSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AC0)cisa_csaf_ot
Currently no fix is available
- Kein Fix verfügbarSIPLUS S7-1500 CPU 1518-4 PN/DP MFP (6AG1518-4AX00-4AC0)cisa_csaf_ot
Currently no fix is available
cvss
Technischer Schweregrad, 0–10. Eine Zeile je Quelle.
Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen⚠ Quellen uneinig · medium–high · 6.9–7.5
SSVC
Eine Handlungsentscheidung — aus Ausnutzung und Auswirkung.
schwächen
Die CWE-Schwächeklassen, zu denen dies gehört.
betroffene Produkte (345)
Betroffene Produkte und Versionsbereiche.
Advisories (23)
Hersteller- und Ökosystem-Meldungen dazu.
- NCSC-2024-0433Kwetsbaarheden verholpen in Siemens productenNL2024-11-12csaf · ncsc_nlNL
Siemens heeft kwetsbaarheden verholpen in diverse producten als Mendix, RUGGEDCOM, SCALANCE, SIMATIC en SINEC.
- NCSC-2025-0061Kwetsbaarheden verholpen in Siemens productenNL2025-02-14csaf · ncsc_nlNL
Siemens heeft kwetsbaarheden verholpen in diverse producten als APOGEE, Opcenter, RUGGEDCOM, SCALANCE, SIMATIC, SIPROTEC en Teamcenter.
- NCSC-2025-0106Kwetsbaarheden verholpen in Siemens productenNL2025-04-08csaf · ncsc_nlNL
Siemens heeft kwetsbaarheden verholpen in diverse producten als Industrial Edge Devices, Mendix, SENTRON, SIDIS, SIMATIC, SIPLUS,Insights Hub Private Cloud, Siemens License Server en Solid Edge.
- NCSC-2025-0187Kwetsbaarheden verholpen in Siemens productenNL2025-06-10csaf · ncsc_nlNL
Siemens heeft kwetsbaarheden verholpen in diverse producten als RUGGEDCOM, SCALANCE, SIMATIC en Tecnomatix
- SSA-082556SSA-082556: Vulnerabilities in the additional GNU/Linux subsystem of the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP V3.1.52025-06-10csaf · siemens_psirtDE
Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the firmware version V3.1.5 for the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP (incl. SIPLUS variant). Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fixes and recommends specific mitigations for products where fixes are not or not yet available. SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP V3.1.5 is no longer maintained and there won't be any update to the CVE list anymore. Please update to the latest version. Note: This SSA advises vulnerabilities for firmware version V3.1.5 only; for version V3.1.6 refer to SSA-019113.
- SSA-093430SSA-093430: Multiple Vulnerabilities in SIMATIC RTLS Locating Manager before V3.02024-05-14csaf · siemens_psirtDE
Siemens has released a new version for SIMATIC RTLS Locating Manager and recommends to update to the latest version.
- SSA-277137SSA-277137: Multiple Vulnerabilities in SIDIS Prime Before V4.0.7002025-04-08csaf · siemens_psirtDE
SIDIS Prime before V4.0.700 is affected by multiple vulnerabilities in the components OpenSSL, SQLite, Boost C++ Libraries and several Microsoft components as described below. Siemens has released a new version of SIDIS Prime and recommends to update to the latest version.
- SSA-331112SSA-331112: Multiple Vulnerabilities in SINEC NMS Before V3.0 SP12024-11-12csaf · siemens_psirtDE
SINEC NMS before V3.0 SP1 is affected by multiple vulnerabilities. Siemens has released a new version for SINEC NMS and recommends to update to the latest version.
- SSA-769027SSA-769027: Multiple Vulnerabilities fixed in SCALANCE W700 IEEE 802.11ax devices before V3.0.02025-02-11csaf · siemens_psirtDE
SCALANCE W-700 IEEE 802.11ax family devices are affected by multiple vulnerabilities. Siemens has released new versions for the affected products and recommends to update to the latest versions.
- VDE-2024-073Phoenix Contact: Multiple Vulnerabilities in PLCnext Firmware2024-12-09csaf · phoenix_contact_psirtDE
Multiple Linux component vulnerabilities fixed in latest PLCnext Firmware release 2024.0.6 LTS
- WID-SEC-W-2023-2741OpenSSL: Schwachstelle ermöglicht Offenlegung von InformationenDeutsch2023-10-24csaf · cert_bundDE
Ein entfernter, anonymer Angreifer kann eine Schwachstelle in OpenSSL ausnutzen, um Informationen offenzulegen.
- WID-SEC-W-2023-3032Tenable Security Nessus Network Monitor: Mehrere SchwachstellenDeutsch2023-11-29csaf · cert_bundDE
Ein entfernter anonymer Angreifer kann mehrere Schwachstellen in Tenable Security Nessus Network Monitor ausnutzen, um vertrauliche Informationen offenzulegen, beliebigen Code auszuführen oder Dateien zu manipulieren.
- WID-SEC-W-2024-0119Oracle MySQL: Mehrere SchwachstellenDeutsch2024-01-16csaf · cert_bundDE
Ein entfernter, anonymer oder authentisierter Angreifer kann mehrere Schwachstellen in Oracle MySQL ausnutzen, um die Vertraulichkeit, Integrität und Verfügbarkeit zu gefährden.
- WID-SEC-W-2024-0869Oracle Communications: Mehrere SchwachstellenDeutsch2024-04-16csaf · cert_bundDE
Ein entfernter, anonymer Angreifer kann mehrere Schwachstellen in Oracle Communications ausnutzen, um die Vertraulichkeit, Integrität und Verfügbarkeit zu gefährden.
- WID-SEC-W-2024-1248Xerox FreeFlow Print Server: Mehrere SchwachstellenDeutsch2024-05-28csaf · cert_bundDE
Ein Angreifer kann mehrere Schwachstellen in Xerox FreeFlow Print Server ausnutzen, um die Vertraulichkeit, Verfügbarkeit und Integrität des Systems zu gefährden
- WID-SEC-W-2024-1488IBM InfoSphere Information Server: Mehrere SchwachstellenDeutsch2024-06-30csaf · cert_bundDE
Ein entfernter Angreifer kann mehrere Schwachstellen in IBM InfoSphere Information Server ausnutzen, um beliebigen Programmcode auszuführen, einen Cross-Site-Scripting-Angriff durchzuführen, Sicherheitsmaßnahmen zu umgehen, einen Denial-of-Service-Zustand zu erzeugen und vertrauliche Informationen offenzulegen.
- WID-SEC-W-2024-1591Juniper JUNOS: Mehrere SchwachstellenDeutsch2024-07-10csaf · cert_bundDE
Ein Angreifer kann mehrere Schwachstellen in Juniper JUNOS ausnutzen, um einen Denial of Service zu verursachen, Informationen offenzulegen, Privilegien zu erweitern und Sicherheitsmechanismen inklusive zu umgehen.
- WID-SEC-W-2025-0647Splunk Splunk Enterprise: Mehrere SchwachstellenDeutsch2025-03-26csaf · cert_bundDE
Ein Angreifer kann mehrere Schwachstellen in Splunk Splunk Enterprise ausnutzen, um Sicherheitsmaßnahmen zu umgehen, vertrauliche Informationen preiszugeben, Daten zu manipulieren, Code auszuführen, einen Denial-of-Service-Zustand zu verursachen und weitere, nicht spezifizierte Auswirkungen zu verursachen.
- ICSA-24-137-07Siemens SIMATIC RTLS Locating Manager2024-05-14icsa · cisa_csaf_otUS
Siemens has released a new version for SIMATIC RTLS Locating Manager and recommends to update to the latest version.
- ICSA-24-319-04Siemens SINEC NMS2024-11-12icsa · cisa_csaf_otUS
SINEC NMS before V3.0 SP1 is affected by multiple vulnerabilities. Siemens has released a new version for SINEC NMS and recommends to update to the latest version.
- ICSA-25-044-09Siemens SCALANCE W700 IEEE 802.11ax2025-02-11icsa · cisa_csaf_otUS
SCALANCE W-700 IEEE 802.11ax family devices are affected by multiple vulnerabilities. Siemens has released new versions for the affected products and recommends to update to the latest versions.
- ICSA-25-100-02Siemens SIDIS Prime2025-04-08icsa · cisa_csaf_otUS
SIDIS Prime before V4.0.700 is affected by multiple vulnerabilities in the components OpenSSL, SQLite, Boost C++ Libraries and several Microsoft components as described below. Siemens has released a new version of SIDIS Prime and recommends to update to the latest version.
- ICSA-25-162-05Siemens SIMATIC S7-1500 CPU family2025-06-10icsa · cisa_csaf_otUS
Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the firmware version V3.1.5 for the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP (incl. SIPLUS variant). Siemens is preparing fix versions and recommends countermeasures for products where fixes are not, or not yet available.
auch bekannt als (4)
Weitere Namen und Kennungen dieser Entität.
quellen
Welche Quellen diesen Datensatz belegen und wann.
Referenzen (31)
Externe Belege — Patches, Meldungen, Analysen.
- http://www.openwall.com/lists/oss-security/2023/10/24/1cnnvd
- https://access.redhat.com/security/cve/cve-2023-5363cnnvd
- https://cxsecurity.com/cveshow/CVE-2023-5363/cnnvd
- https://git.openssl.org/gitweb/?p=openssl.git;a=commitdiff;h=0df40630850fb2740e6be6890bb905d3fc623b2dcnnvd
- https://git.openssl.org/gitweb/?p=openssl.git;a=commitdiff;h=5f69f5c65e483928c4b28ed16af6e5742929f1eecnnvd
- https://security.netapp.com/advisory/ntap-20231027-0010/cnnvd
- https://www.auscert.org.au/bulletins/ESB-2023.6194cnnvd
- https://www.auscert.org.au/bulletins/ESB-2023.7196cnnvd
Angreifer nutzen Schwachstellen wie diese gegen im Internet exponierte Dienste aus. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.
Kostenloser Scan