CVE-2023-49691

mediumPriorität · verfolgen · 27EPSS 0.006 · 50. PerzentilDEEUNLRUUS
grimoire priorityP3 · Track
Exploitable?
—
no known exploitation
Likely / severe?
0.64% (50th) EPSS
CVSS 6.7 · medium
Is it mine?
117 products
Prüfe deine Angriffsfläche
Who says so?
6 sources
cnnvd · enisa_euvd · fstec_bdu · cisa_csaf_ot

EPSS · bewertet 2026-10-22

A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) (All versions < V8.0), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2) (All versions < V8.0), SCALANCE M804PB (6GK5804-0AP00-2AA2) (All versions < V8.0), SCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2) (All versions < V8.0), SCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2) (All versions < V8.0), SCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2) (All versions < V8.0), SCALANCE M816-1 ADSL-Router (6GK5816-1BA00-2AA2) (All versions < V8.0), SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2) (All versions < V8.0), SCALANCE M874-2 (6GK5874-2AA00-2AA2) (All versions < V8.0), SCALANCE M874-3 (6GK5874-3AA00-2AA2) (All versions < V8.0), SCALANCE M876-3 (6GK5876-3AA02-2BA2) (All versions < V8.0), SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2) (All versions < V8.0), SCALANCE M876-4 (6GK5876-4AA10-2BA2) (All versions < V8.0), SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2) (All versions < V8.0), SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2) (All versions < V8.0), SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1) (All versions < V8.0), SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1) (All versions < V8.0), SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1) (All versions < V8.0), SCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2) (All versions < V8.0), SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2) (All versions < V8.0). An Improper Neutralization of Special Elements used in an OS Command with root privileges vulnerability exists in the handling of the DDNS configuration. This could allow malicious local administrators to issue commands on system level after a successful IP address update.

01

Behebungen

Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.

Ein Hersteller-Fix ist verfügbar.

02

cvss

Technischer Schweregrad, 0–10. Eine Zeile je Quelle.

7.2
010

Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen⚠ Quellen uneinig · medium–high · 6.1–7.2

v3.16.7mediumCVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:Hprimary · NVD / NIST USAusnutzbarkeit 0.8 · Auswirkung 5.9
v3.17.2highCVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:Csecondary · CISA US
v3.17.2highAV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:Hsecondary · FSTEC (BDU) RU
v3.17.2highCVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:Csecondary · ENISA EU
v3.17.2highCVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:Hsecondary · productcert@siemens.com DEAusnutzbarkeit 1.2 · Auswirkung 5.9
v3.17.2highCVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:Csecondary · Siemens ProductCERT DE
v3.16.1mediumCVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:Usecondary · CVSS-BT (t0sche)
03

schwächen

Die CWE-Schwächeklassen, zu denen dies gehört.

04

betroffene Produkte (117)

Betroffene Produkte und Versionsbereiche.

05

Advisories (5)

Hersteller- und Ökosystem-Meldungen dazu.

  • NCSC-2024-0246Kwetsbaarheden verholpen in Siemens productenNL2024-06-11csaf · ncsc_nlNL

    Siemens heeft kwetsbaarheden verholpen in diverse producten, zoals SCALANCE, SICAM, Tecnomatix, SITOP en PowerSys.

  • SSA-180704SSA-180704: Multiple Vulnerabilities in SCALANCE M-800 Family Before V8.02023-12-12csaf · siemens_psirtDE

    SCALANCE M-800 family before V8.0 is affected by multiple vulnerabilities. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends countermeasures for products where fixes are not, or not yet available.

  • SSA-602936SSA-602936: Multiple Vulnerabilities in SCALANCE SC-600 Family before V3.12024-02-13csaf · siemens_psirtDE

    SCALANCE SC-600 Family before V3.1 is affected by multiple vulnerabilities. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends countermeasures for products where fixes are not, or not yet available.

  • ICSA-23-348-14Siemens RUGGEDCOM and SCALANCE M-800/S615 Family2023-12-12icsa · cisa_csaf_otUS

    SCALANCE M-800 family before V8.0 is affected by multiple vulnerabilities. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends countermeasures for products where fixes are not, or not yet available.

  • ICSA-24-046-09Siemens SCALANCE SC-600 Family2024-02-13icsa · cisa_csaf_otUS

    SCALANCE SC-600 Family before V3.1 is affected by multiple vulnerabilities. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends countermeasures for products where fixes are not, or not yet available.

06

auch bekannt als (5)

Weitere Namen und Kennungen dieser Entität.

07

quellen

Welche Quellen diesen Datensatz belegen und wann.

08

Referenzen (13)

Externe Belege — Patches, Meldungen, Analysen.

scry

Angreifer nutzen Schwachstellen wie diese gegen im Internet exponierte Dienste aus. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.

Kostenloser Scan