CVE-2023-49069
mediumPriorität · verfolgen · 0EPSS 0.004 · 37. PerzentilDEEUNLRUUSEPSS · bewertet 2026-10-22
A vulnerability has been identified in Mendix Runtime V10 (All versions < V10.17.0 only if the basic authentication mechanism is used by the application), Mendix Runtime V10.12 (All versions < V10.12.11 only if the basic authentication mechanism is used by the application), Mendix Runtime V10.6 (All versions < V10.6.19 only if the basic authentication mechanism is used by the application), Mendix Runtime V8 (All versions < V8.18.33 only if the basic authentication mechanism is used by the application), Mendix Runtime V9 (All versions < V9.24.31 only if the basic authentication mechanism is used by the application). The authentication mechanism of affected applications contains an observable response discrepancy vulnerability when validating usernames. This could allow unauthenticated remote attackers to distinguish between valid and invalid usernames.
Behebungen
Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.
Ein Hersteller-Fix ist verfügbar.
- BehobenMendix Runtime V10siemens_psirt
Update to V10.17.0 or later version
https://docs.mendix.com/releasenotes/studio-pro/10/ - BehobenMendix Runtime V10.12siemens_psirt
Update to V10.12.11 or later version
https://docs.mendix.com/releasenotes/studio-pro/10/ - BehobenMendix Runtime V10.6siemens_psirt
Update to V10.6.19 or later version
https://docs.mendix.com/releasenotes/studio-pro/10/ - BehobenMendix Runtime V8siemens_psirt
Update to V8.18.33 or later version
https://docs.mendix.com/releasenotes/studio-pro/8/ - BehobenMendix Runtime V9siemens_psirt
Update to V9.24.31 or later version
https://docs.mendix.com/releasenotes/studio-pro/9/ - BehobenMendix Runtime V10cisa_csaf_ot
Update to V10.17.0 or later version
https://docs.mendix.com/releasenotes/studio-pro/10/ - BehobenMendix Runtime V10.12cisa_csaf_ot
Update to V10.12.11 or later version
https://docs.mendix.com/releasenotes/studio-pro/10/ - BehobenMendix Runtime V10.6cisa_csaf_ot
Update to V10.6.19 or later version
https://docs.mendix.com/releasenotes/studio-pro/10/ - BehobenMendix Runtime V8cisa_csaf_ot
Update to V8.18.33 or later version
https://docs.mendix.com/releasenotes/studio-pro/8/ - BehobenMendix Runtime V9cisa_csaf_ot
Update to V9.24.31 or later version
https://docs.mendix.com/releasenotes/studio-pro/9/ - MitigationMendix Runtime V10siemens_psirt
For app user login: Do not use basic authentication, but setup an alternative authentication module (e.g. OIDC SSO, Mendix SSO, or SAML >= V4.0.0), or your own Identity Provider (IDP).
- MitigationMendix Runtime V10.12siemens_psirt
For app user login: Do not use basic authentication, but setup an alternative authentication module (e.g. OIDC SSO, Mendix SSO, or SAML >= V4.0.0), or your own Identity Provider (IDP).
- MitigationMendix Runtime V10.6siemens_psirt
For app user login: Do not use basic authentication, but setup an alternative authentication module (e.g. OIDC SSO, Mendix SSO, or SAML >= V4.0.0), or your own Identity Provider (IDP).
- MitigationMendix Runtime V8siemens_psirt
For app user login: Do not use basic authentication, but setup an alternative authentication module (e.g. OIDC SSO, Mendix SSO, or SAML >= V4.0.0), or your own Identity Provider (IDP).
- MitigationMendix Runtime V9siemens_psirt
For app user login: Do not use basic authentication, but setup an alternative authentication module (e.g. OIDC SSO, Mendix SSO, or SAML >= V4.0.0), or your own Identity Provider (IDP).
- MitigationMendix Runtime V10cisa_csaf_ot
For app user login: Do not use basic authentication, but setup an alternative authentication module (e.g. OIDC SSO, Mendix SSO, or SAML >= V4.0.0), or your own Identity Provider (IDP).
- MitigationMendix Runtime V10.12cisa_csaf_ot
For app user login: Do not use basic authentication, but setup an alternative authentication module (e.g. OIDC SSO, Mendix SSO, or SAML >= V4.0.0), or your own Identity Provider (IDP).
- MitigationMendix Runtime V10.6cisa_csaf_ot
For app user login: Do not use basic authentication, but setup an alternative authentication module (e.g. OIDC SSO, Mendix SSO, or SAML >= V4.0.0), or your own Identity Provider (IDP).
- MitigationMendix Runtime V8cisa_csaf_ot
For app user login: Do not use basic authentication, but setup an alternative authentication module (e.g. OIDC SSO, Mendix SSO, or SAML >= V4.0.0), or your own Identity Provider (IDP).
- MitigationMendix Runtime V9cisa_csaf_ot
For app user login: Do not use basic authentication, but setup an alternative authentication module (e.g. OIDC SSO, Mendix SSO, or SAML >= V4.0.0), or your own Identity Provider (IDP).
cvss
Technischer Schweregrad, 0–10. Eine Zeile je Quelle.
Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen⚠ Quellen uneinig · low–medium · 2.7–6.9
SSVC
Eine Handlungsentscheidung — aus Ausnutzung und Auswirkung.
schwächen
Die CWE-Schwächeklassen, zu denen dies gehört.
betroffene Produkte (34)
Betroffene Produkte und Versionsbereiche.
Advisories (3)
Hersteller- und Ökosystem-Meldungen dazu.
- NCSC-2024-0362Kwetsbaarheden verholpen in Siemens productenNL2024-09-10csaf · ncsc_nlNL
Siemens heeft kwetsbaarheden verholpen in diverse producten als Mendix, SICAM, SIMATIC, SINEMA, SINUMERIK en Tecnomatix.
- SSA-097435SSA-097435: Usernames Disclosure Vulnerability in Mendix Runtime2024-09-10csaf · siemens_psirtDE
Mendix Runtime contains an observable response discrepancy vulnerability when validating usernames during authentication. This could allow unauthenticated remote attackers to distinguish between valid and invalid usernames. Siemens has released new versions for the affected products and recommends to update to the latest versions.
- ICSA-24-256-05Siemens Mendix Runtime2024-09-10icsa · cisa_csaf_otUS
Mendix Runtime contains an observable response discrepancy vulnerability when validating usernames during authentication. This could allow unauthenticated remote attackers to distinguish between valid and invalid usernames. Siemens has released new versions for the affected products and recommends to update to the latest versions.