CVE-2023-48693
criticalPriorität · verfolgen · 39EPSS 0.013 · 70. PerzentilEUUSEPSS · bewertet 2026-10-27
Azure RTOS ThreadX is an advanced real-time operating system (RTOS) designed specifically for deeply embedded applications. An attacker can cause arbitrary read and write due to vulnerability in parameter checking mechanism in Azure RTOS ThreadX, which may lead to privilege escalation. The affected components include RTOS ThreadX v6.2.1 and below. The fixes have been included in ThreadX release 6.3.0. Users are advised to upgrade. There are no known workarounds for this vulnerability.
Behebungen
Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.
Ein Hersteller-Fix ist verfügbar.
- BehobenPLC Micro820 LC20cisa_csaf_ot
PLC Micro820 LC20: Migrate to Micro820 L20E V23.011 and later (this has yet to be released, target to release in Sept 2025)
https://www.rockwellautomation.com/en-ca/support/product/product-downloads.html - BehobenPLC Micro850 L50Ecisa_csaf_ot
PLC Micro850 L50E: V23.011 and later
https://www.rockwellautomation.com/en-ca/support/product/product-downloads.html - BehobenPLC Micro850 LC50cisa_csaf_ot
PLC Micro850 LC50: Migrate to Micro850 L50E V23.011 and later
https://www.rockwellautomation.com/en-ca/support/product/product-downloads.html - BehobenPLC Micro870 L70Ecisa_csaf_ot
PLC Micro870 L70E: V23.011 and later
https://www.rockwellautomation.com/en-ca/support/product/product-downloads.html - BehobenPLC Micro870 LC70cisa_csaf_ot
PLC Micro870 LC70: Migrate to Micro870 L70E V23.011 and later
https://www.rockwellautomation.com/en-ca/support/product/product-downloads.html - MitigationPLC Micro820 LC20cisa_csaf_ot
Rockwell Automation recommends the following updates:
- MitigationPLC Micro850 L50Ecisa_csaf_ot
Rockwell Automation recommends the following updates:
- MitigationPLC Micro850 LC50cisa_csaf_ot
Rockwell Automation recommends the following updates:
- MitigationPLC Micro870 L70Ecisa_csaf_ot
Rockwell Automation recommends the following updates:
- MitigationPLC Micro870 LC70cisa_csaf_ot
Rockwell Automation recommends the following updates:
cvss
Technischer Schweregrad, 0–10. Eine Zeile je Quelle.
Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen⚠ Quellen uneinig · high–critical · 8.7–9.8
schwächen
Die CWE-Schwächeklassen, zu denen dies gehört.
betroffene Produkte (12)
Betroffene Produkte und Versionsbereiche.
Advisories (1)
Hersteller- und Ökosystem-Meldungen dazu.
- ICSA-25-226-25Rockwell Automation Micro8002025-08-14icsa · cisa_csaf_otUS
Successful exploitation of these vulnerabilities could result in remote code execution or may lead to privilege escalation.
auch bekannt als (2)
Weitere Namen und Kennungen dieser Entität.
quellen
Welche Quellen diesen Datensatz belegen und wann.
Referenzen (3)
Externe Belege — Patches, Meldungen, Analysen.
Angreifer nutzen Schwachstellen wie diese gegen im Internet exponierte Dienste aus. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.
Kostenloser Scan