CVE-2023-46282

mediumPriorität · verfolgen · 24EPSS 0.005 · 42. PerzentilDEEURUUS
grimoire priorityP3 · Track
Exploitable?
—
no known exploitation
Likely / severe?
0.49% (42nd) EPSS
CVSS 6.1 · medium
Is it mine?
57 products
Prüfe deine Angriffsfläche
Who says so?
6 sources
cnnvd · enisa_euvd · fstec_bdu · cert_bund

EPSS · bewertet 2026-10-27

A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2407), Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). A reflected cross-site scripting (XSS) vulnerability exists in the web interface of the affected applications that could allow an attacker to inject arbitrary JavaScript code. The code could be potentially executed later by another (possibly privileged) user.

01

Behebungen

Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.

Ein Hersteller-Fix ist verfügbar.

  • BehobenOpcenter Execution Foundationsiemens_psirt

    Update to V2407 or later version

  • BehobenOpcenter Qualitysiemens_psirt

    Update to V2312 or later version

  • BehobenSIMATIC PCS neosiemens_psirt

    Update to V4.1 or later version

  • BehobenSINEC NMSsiemens_psirt

    Update to V2.0 SP1 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109826954/
  • BehobenTotally Integrated Automation Portal (TIA Portal) V17siemens_psirt

    Update to V17 Update 8 or later version

  • BehobenTotally Integrated Automation Portal (TIA Portal) V18siemens_psirt

    Update to V18 Update 3 or later version

  • BehobenOpcenter Execution Foundationcisa_csaf_ot

    Update to V2407 or later version

  • BehobenOpcenter Qualitycisa_csaf_ot

    Update to V2312 or later version

  • BehobenSIMATIC PCS neocisa_csaf_ot

    Update to V4.1 or later version

  • BehobenSINEC NMScisa_csaf_ot

    Update to V2.0 SP1 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109826954/
  • BehobenTotally Integrated Automation Portal (TIA Portal) V17cisa_csaf_ot

    Update to V17 Update 8 or later version

  • BehobenTotally Integrated Automation Portal (TIA Portal) V18cisa_csaf_ot

    Update to V18 Update 3 or later version

  • WorkaroundOpcenter Execution Foundationsiemens_psirt

    CVE-2023-46281, CVE-2023-46282: Do not access links from untrusted sources

  • WorkaroundOpcenter Qualitysiemens_psirt

    CVE-2023-46281, CVE-2023-46282: Do not access links from untrusted sources

  • WorkaroundSIMATIC PCS neosiemens_psirt

    CVE-2023-46281, CVE-2023-46282: Do not access links from untrusted sources

  • WorkaroundSINEC NMSsiemens_psirt

    CVE-2023-46281, CVE-2023-46282: Do not access links from untrusted sources

  • WorkaroundTotally Integrated Automation Portal (TIA Portal) V14siemens_psirt

    CVE-2023-46281, CVE-2023-46282: Do not access links from untrusted sources

  • WorkaroundTotally Integrated Automation Portal (TIA Portal) V15.1siemens_psirt

    CVE-2023-46281, CVE-2023-46282: Do not access links from untrusted sources

  • WorkaroundTotally Integrated Automation Portal (TIA Portal) V16siemens_psirt

    CVE-2023-46281, CVE-2023-46282: Do not access links from untrusted sources

  • WorkaroundTotally Integrated Automation Portal (TIA Portal) V17siemens_psirt

    CVE-2023-46281, CVE-2023-46282: Do not access links from untrusted sources

  • WorkaroundTotally Integrated Automation Portal (TIA Portal) V18siemens_psirt

    CVE-2023-46281, CVE-2023-46282: Do not access links from untrusted sources

  • WorkaroundOpcenter Execution Foundationcisa_csaf_ot

    CVE-2023-46281, CVE-2023-46282: Do not access links from untrusted sources

  • WorkaroundOpcenter Qualitycisa_csaf_ot

    CVE-2023-46281, CVE-2023-46282: Do not access links from untrusted sources

  • WorkaroundSIMATIC PCS neocisa_csaf_ot

    CVE-2023-46281, CVE-2023-46282: Do not access links from untrusted sources

  • WorkaroundSINEC NMScisa_csaf_ot

    CVE-2023-46281, CVE-2023-46282: Do not access links from untrusted sources

  • WorkaroundTotally Integrated Automation Portal (TIA Portal) V14cisa_csaf_ot

    CVE-2023-46281, CVE-2023-46282: Do not access links from untrusted sources

  • WorkaroundTotally Integrated Automation Portal (TIA Portal) V15.1cisa_csaf_ot

    CVE-2023-46281, CVE-2023-46282: Do not access links from untrusted sources

  • WorkaroundTotally Integrated Automation Portal (TIA Portal) V16cisa_csaf_ot

    CVE-2023-46281, CVE-2023-46282: Do not access links from untrusted sources

  • WorkaroundTotally Integrated Automation Portal (TIA Portal) V17cisa_csaf_ot

    CVE-2023-46281, CVE-2023-46282: Do not access links from untrusted sources

  • WorkaroundTotally Integrated Automation Portal (TIA Portal) V18cisa_csaf_ot

    CVE-2023-46281, CVE-2023-46282: Do not access links from untrusted sources

  • Kein Fix geplantTotally Integrated Automation Portal (TIA Portal) V14siemens_psirt

    Currently no fix is planned

  • Kein Fix geplantTotally Integrated Automation Portal (TIA Portal) V15.1siemens_psirt

    Currently no fix is planned

  • Kein Fix geplantTotally Integrated Automation Portal (TIA Portal) V16siemens_psirt

    Currently no fix is planned

  • Kein Fix geplantTotally Integrated Automation Portal (TIA Portal) V14cisa_csaf_ot

    Currently no fix is planned

  • Kein Fix geplantTotally Integrated Automation Portal (TIA Portal) V15.1cisa_csaf_ot

    Currently no fix is planned

  • Kein Fix geplantTotally Integrated Automation Portal (TIA Portal) V16cisa_csaf_ot

    Currently no fix is planned

02

cvss

Technischer Schweregrad, 0–10. Eine Zeile je Quelle.

7.1
010

Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen⚠ Quellen uneinig · medium–high · 5.6–7.1

v3.16.1mediumCVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:Nprimary · NVD / NIST USAusnutzbarkeit 2.8 · Auswirkung 2.7
v3.17.1highCVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:L/E:P/RL:O/RC:Csecondary · CISA US
v3.17.1highAV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:Lsecondary · FSTEC (BDU) RU
v3.17.1highCVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:L/E:P/RL:O/RC:Csecondary · ENISA EU
v3.17.1highCVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:Lsecondary · productcert@siemens.com DEAusnutzbarkeit 1.6 · Auswirkung 5.5
v3.17.1highCVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:L/E:P/RL:O/RC:Csecondary · Siemens ProductCERT DE
v3.15.6mediumCVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N/E:Usecondary · CVSS-BT (t0sche)
03

schwächen

Die CWE-Schwächeklassen, zu denen dies gehört.

04

betroffene Produkte (57)

Betroffene Produkte und Versionsbereiche.

05

Advisories (3)

Hersteller- und Ökosystem-Meldungen dazu.

  • SSA-999588SSA-999588: Multiple Vulnerabilities in User Management Component (UMC) Before V2.11.22023-12-12csaf · siemens_psirtDE

    Siemens User Management Component (UMC) before V2.11.2 is affected by multiple vulnerabilities where the most severe could lead to a restart of the UMC server. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for products where fixes are not, or not yet available.

  • WID-SEC-W-2023-3100Siemens TIA Portal: Mehrere SchwachstellenDeutsch2023-12-11csaf · cert_bundDE

    Ein Angreifer kann mehrere Schwachstellen in Siemens TIA Portal ausnutzen, um ein unerwünschtes Verhalten auszulösen, einen Cross Site Scripting Angriff durchzuführen oder einen Denial of Service zu verursachen.

  • ICSA-23-348-03Siemens User Management Component (UMC)2023-12-12icsa · cisa_csaf_otUS

    Siemens User Management Component (UMC) before V2.11.2 is affected by multiple vulnerabilities where the most severe could lead to a restart of the UMC server. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for products where fixes are not, or not yet available.

06

auch bekannt als (5)

Weitere Namen und Kennungen dieser Entität.

07

quellen

Welche Quellen diesen Datensatz belegen und wann.

09

Referenzen (8)

Externe Belege — Patches, Meldungen, Analysen.

scry

Angreifer nutzen Schwachstellen wie diese gegen im Internet exponierte Dienste aus. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.

Kostenloser Scan