Download of Code Without Integrity Check vulnerability in PHOENIX CONTACT classic line PLCs allows an unauthenticated remote attacker to modify some or all applications on a PLC.
Behebungen
Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.
Ein Hersteller-Fix ist verfügbar.
- BehobenRTU500 series CMU Firmwarecisa_csaf_ot
Upgrade to version 12.7.8 or 13.9.1 or latest
- Mitigationphoenix_contact_psirt
Phoenix Contact classic line controllers are developed and designed for use in closed industrial networks. In this approach, the production plant is protected against attacks, especially from the outside, by a multi-level perimeter, including firewalls, and by dividing the plant into OT zones using firewalls. This concept is supported by organizational measures in the production facility as part of a security management system. To achieve security here, measures are required at all levels. It must be ensured that logic is always transferred or stored in protected environments. It applies to both data in transmission and data at rest. Connections between the engineering tools (Automation Worx Software Suite) and the controller must always be in a locally protected environment or, in the case of remote access, protected by VPN. Project data should not be sent as a file via email or other transmission mechanisms without additional integrity and authenticity checks. Project data should only be stored in protected environments. Customers using Phoenix Contact classic line controllers are recommended to operate the devices as intended in closed networks or protected with a suitable firewall. For general information and recommendations on security measures to protect network-enabled devices, refer to the application note: Application note Security external link If a classic line controller can't be used in protected zones, the OT communication protocols should be disabled. Depending on the controller type, this can be done either via CPU services via console or web-based management. Information on which controllers and from which firmware version onwards communication protocols can be deactivated is described in the application note for classic line controllers or in the manual for the respective controller, which is available for download on the Phoenix Contact website. A summary of measures to protect devices based on classic control technology is provided here: Measures to protect devices based on classic control technology
cvss
Technischer Schweregrad, 0–10. Eine Zeile je Quelle.
Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen⚠ Quellen uneinig · medium–high · 6.9–7.5
SSVC
Eine Handlungsentscheidung — aus Ausnutzung und Auswirkung.
schwächen
Die CWE-Schwächeklassen, zu denen dies gehört.
betroffene Produkte (78)
Betroffene Produkte und Versionsbereiche.
Advisories (3)
Hersteller- und Ökosystem-Meldungen dazu.
- VDE-2023-057Phoenix Contact: Classic line industrial controllers prone to inadequate integrity check of PLC2023-12-12csaf · phoenix_contact_psirtDE
Phoenix Contact classic line industrial controllers are developed and designed for the use in closed industrial networks. The controllers don't feature a function to check integrity and authenticity of the application (e.g.: logic files, executable logic, configurations). A CRC Check warning the user if the application of the Engineering tool and the PLC differs can be manipulated.
- WID-SEC-W-2026-3658Hitachi Energy RTU500: Mehrere SchwachstellenDeutsch2026-09-29csaf · cert_bundDE
Ein Angreifer kann mehrere Schwachstellen in Hitachi Energy RTU500 ausnutzen, um beliebigen Code auszuführen, Sicherheitsmaßnahmen zu umgehen, die Gerätefunktionalität zu verändern oder Denial-of-Service-Zustände zu verursachen.
- ICSA-26-279-06Hitachi Energy RTU5002026-09-29icsa · cisa_csaf_otUS
Hitachi Energy is publishing this cybersecurity advisory in response to the security findings reported by Dragos affecting end-of-life RTU500 CMU firmware version 9.x. The reported findings are associated with legacy RTU500 firmware versions that were developed according to the cybersecurity requirements, threat landscape, and industry practices that existed at the time of their release. As cybersecurity threats and security expectations have evolved, these end-of-life versions no longer incorporate many of the security controls and hardening measures that are standard in modern industrial control systems. Over successive RTU500 releases, Hitachi Energy has continuously enhanced the security of the product through the introduction of additional security features, protocol hardening, stronger authentication and access controls, encrypted communications, and other security-by-design improvements. While the findings reported by Dragos do not affect currently supported RTU500 CMU firmware versions, there is a likelihood that the end-of-life versions 11.x and prior are affected by these vulnerabilities. Since the end-of-life versions are no longer maintained with security updates, Hitachi Energy strongly recommends upgrading to a currently supported RTU500 firmware version. Customers should also implement appropriate defense-in-depth measures and cybersecurity best practices to reduce risk and strengthen the security posture of their operational environments. Please refer to the Recommended Immediate Actions for information about the mitigation/remediation.
auch bekannt als (5)
Weitere Namen und Kennungen dieser Entität.
quellen
Welche Quellen diesen Datensatz belegen und wann.
Referenzen (5)
Externe Belege — Patches, Meldungen, Analysen.
Angreifer nutzen Schwachstellen wie diese gegen im Internet exponierte Dienste aus. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.
Kostenloser Scan