CVE-2023-44321

mediumPriorität · verfolgen · 26EPSS 0.010 · 63. PerzentilDEEUNLRUUS
grimoire priorityP3 · Track
Exploitable?
—
no known exploitation
Likely / severe?
1.00% (63rd) EPSS
CVSS 6.5 · medium
Is it mine?
518 products
Prüfe deine Angriffsfläche
Who says so?
6 sources
cnnvd · enisa_euvd · fstec_bdu · cisa_csaf_ot

EPSS · bewertet 2026-10-27

Affected devices do not properly validate the length of inputs when performing certain configuration changes in the web interface allowing an authenticated attacker to cause a denial of service condition. The device needs to be restarted for the web interface to become available again.

01

Behebungen

Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.

Ein Hersteller-Fix ist verfügbar.

02

cvss

Technischer Schweregrad, 0–10. Eine Zeile je Quelle.

6.5
010

Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen⚠ Quellen uneinig · low–medium · 1.2–6.5

v3.16.5mediumCVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:Hprimary · NVD / NIST USAusnutzbarkeit 2.8 · Auswirkung 3.6
v3.12.7lowCVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:Lsecondary · productcert@siemens.com DEAusnutzbarkeit 1.2 · Auswirkung 1.4
v3.12.7lowCVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:Lsecondary · Siemens ProductCERT DE
v3.12.7lowCVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:Lsecondary · CISA US
v3.12.7lowAV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:Lsecondary · FSTEC (BDU) RU
v4.01.2lowCVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N/E:U/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:Xsecondary · CVSS-BT (t0sche)
v4.05.1mediumCVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:Nsecondary · ENISA EU
v4.05.1mediumCVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:Xsecondary · productcert@siemens.com DE
03

SSVC

Eine Handlungsentscheidung — aus Ausnutzung und Auswirkung.

Trackcoordinatorcisa_ssvcUS
04

schwächen

Die CWE-Schwächeklassen, zu denen dies gehört.

05

betroffene Produkte (518)

Betroffene Produkte und Versionsbereiche.

06

Advisories (7)

Hersteller- und Ökosystem-Meldungen dazu.

  • NCSC-2024-0332Kwetsbaarheden verholpen in Siemens productenNL2024-08-13csaf · ncsc_nlNL

    Siemens heeft kwetsbaarheden verholpen in diverse producten als COMOS, INTRALOG, LOGO!, NX, SCALANCE, SINEC en Teamcenter.

  • SSA-087301SSA-087301: Multiple Vulnerabilities in SCALANCE M-800 Family Before V8.12024-08-13csaf · siemens_psirtDE

    SCALANCE M-800 family before V8.1 is affected by multiple vulnerabilities. Siemens has released new versions for the affected products and recommends to update to the latest versions.

  • SSA-353002SSA-353002: Multiple Vulnerabilities in SCALANCE XB-200 / XC-200 / XP-200 / XF-200BA / XR-300WG Family2024-03-12csaf · siemens_psirtDE

    SCALANCE XB-200/XC-200/XP-200/XF-200BA/XR-300WG Family is affected by multiple vulnerabilities. CVE-2023-44318 and CVE-2023-44321 were previously published as part of SSA-699386. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends countermeasures for products where fixes are not, or not yet available.

  • SSA-602936SSA-602936: Multiple Vulnerabilities in SCALANCE SC-600 Family before V3.12024-02-13csaf · siemens_psirtDE

    SCALANCE SC-600 Family before V3.1 is affected by multiple vulnerabilities. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends countermeasures for products where fixes are not, or not yet available.

  • ICSA-24-046-09Siemens SCALANCE SC-600 Family2024-02-13icsa · cisa_csaf_otUS

    SCALANCE SC-600 Family before V3.1 is affected by multiple vulnerabilities. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends countermeasures for products where fixes are not, or not yet available.

  • ICSA-24-074-08Siemens SCALANCE XB-200 / XC-200 / XP-200 / XF-200BA / XR-300WG Family2024-03-12icsa · cisa_csaf_otUS

    SCALANCE XB-200/XC-200/XP-200/XF-200BA/XR-300WG Family is affected by multiple vulnerabilities. CVE-2023-44318 and CVE-2023-44321 were previously published as part of SSA-699386. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends countermeasures for products where fixes are not, or not yet available.

  • ICSA-24-228-01Siemens SCALANCE M-800, RUGGEDCOM RM12242024-08-13icsa · cisa_csaf_otUS

    SCALANCE M-800 family before V8.1 is affected by multiple vulnerabilities. Siemens has released new versions for the affected products and recommends to update to the latest versions.

07

auch bekannt als (6)

Weitere Namen und Kennungen dieser Entität.

08

quellen

Welche Quellen diesen Datensatz belegen und wann.

09

Referenzen (20)

Externe Belege — Patches, Meldungen, Analysen.

scry

Angreifer nutzen Schwachstellen wie diese gegen im Internet exponierte Dienste aus. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.

Kostenloser Scan