CVE-2023-39615
mediumPriorität · verfolgen · 26EPSS 0.011 · 65. PerzentilDEEUNLRUUSEPSS · bewertet 2026-10-22
Xmlsoft Libxml2 v2.11.0 was discovered to contain an out-of-bounds read via the xmlSAX2StartElement() function at /libxml2/SAX2.c. This vulnerability allows attackers to cause a Denial of Service (DoS) via supplying a crafted XML file. NOTE: the vendor's position is that the product does not support the legacy SAX1 interface with custom callbacks; there is a crash even without crafted input.
Behebungen
Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.
Ein Hersteller-Fix ist verfügbar.
- BehobenST7 ScadaConnect (6NH7997-5DA10-0AA0)siemens_psirt
Update to V1.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955597/ - BehobenSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0)siemens_psirt
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AC0)siemens_psirt
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AB0)siemens_psirt
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AC0)siemens_psirt
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1518-4 PN/DP MFP (6AG1518-4AX00-4AC0)siemens_psirt
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenTeleControl Server Basic V3siemens_psirt
Update to V3.1.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955177/ - BehobenSINEC NMSsiemens_psirt
Update to V3.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109973059/ - BehobenSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0)cisa_csaf_ot
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AC0)cisa_csaf_ot
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AB0)cisa_csaf_ot
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AC0)cisa_csaf_ot
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1518-4 PN/DP MFP (6AG1518-4AX00-4AC0)cisa_csaf_ot
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenST7 ScadaConnect (6NH7997-5DA10-0AA0)cisa_csaf_ot
Update to V1.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955597/ - BehobenSINEC NMScisa_csaf_ot
Update to V3.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109973059/ - MitigationSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0)cisa_csaf_ot
Only build and run applications from trusted sources.
- MitigationSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AC0)cisa_csaf_ot
Only build and run applications from trusted sources.
- MitigationSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AB0)cisa_csaf_ot
Only build and run applications from trusted sources.
- MitigationSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AC0)cisa_csaf_ot
Only build and run applications from trusted sources.
- MitigationSIPLUS S7-1500 CPU 1518-4 PN/DP MFP (6AG1518-4AX00-4AC0)cisa_csaf_ot
Only build and run applications from trusted sources.
cvss
Technischer Schweregrad, 0–10. Eine Zeile je Quelle.
Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen
SSVC
Eine Handlungsentscheidung — aus Ausnutzung und Auswirkung.
schwächen
Die CWE-Schwächeklassen, zu denen dies gehört.
betroffene Produkte (45)
Betroffene Produkte und Versionsbereiche.
- Siemens SIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0)≤ vers:intdot/>=3.1.0|<3.1.5cisa_csaf_otUS
- Siemens SIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AC0)≤ vers:intdot/>=3.1.0|<3.1.5cisa_csaf_otUS
- Siemens SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AB0)≤ vers:intdot/>=3.1.0|<3.1.5cisa_csaf_otUS
- Siemens SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AC0)≤ vers:intdot/>=3.1.0|<3.1.5cisa_csaf_otUS
- Siemens SIPLUS S7-1500 CPU 1518-4 PN/DP MFP (6AG1518-4AX00-4AC0)≤ vers:intdot/>=3.1.0|<3.1.5cisa_csaf_otUS
Advisories (13)
Hersteller- und Ökosystem-Meldungen dazu.
- NCSC-2024-0246Kwetsbaarheden verholpen in Siemens productenNL2024-06-11csaf · ncsc_nlNL
Siemens heeft kwetsbaarheden verholpen in diverse producten, zoals SCALANCE, SICAM, Tecnomatix, SITOP en PowerSys.
- NCSC-2024-0332Kwetsbaarheden verholpen in Siemens productenNL2024-08-13csaf · ncsc_nlNL
Siemens heeft kwetsbaarheden verholpen in diverse producten als COMOS, INTRALOG, LOGO!, NX, SCALANCE, SINEC en Teamcenter.
- SSA-341067SSA-341067: Multiple vulnerabilities in third-party components in ST7 ScadaConnect before V1.12024-06-11csaf · siemens_psirtDE
Siemens has released a new version for ST7 ScadaConnect and recommends to update to the latest version.
- SSA-398330SSA-398330: Vulnerabilities in the additional GNU/Linux subsystem of the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP >= V3.1.0 and < V3.1.52023-12-12csaf · siemens_psirtDE
Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the firmware version >= V3.1.0 and < V3.1.5 for the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP (incl. SIPLUS variant). These GNU/Linux vulnerabilities have been externally identified. Siemens has released new versions for the affected products and recommends to update to the latest versions. SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP >= V3.1.0 and < V3.1.5 are no longer maintained and there won't be any update to the CVE list anymore. Please update to the latest version. Note: This SSA advises vulnerabilities for firmware version V3.1 only; for versions < V3.1 refer to Siemens Security Bulletin SSB-439005 (https://cert-portal.siemens.com/productcert/html/ssb-439005.html).
- SSA-556635SSA-556635: Multiple Vulnerabilities in Telecontrol Server Basic before V3.1.2.02024-04-09csaf · siemens_psirtDE
Siemens has released a new version for Telecontrol Server Basic that fixes multiple vulnerabilities.
- SSA-784301SSA-784301: Multiple Vulnerabilities in SINEC NMS Before V3.02024-08-13csaf · siemens_psirtDE
SINEC NMS before V3.0 is affected by multiple vulnerabilities. Siemens has released a new version for SINEC NMS and recommends to update to the latest version.
- WID-SEC-W-2023-2214libxml2: Schwachstelle ermöglicht Denial of ServiceDeutsch2023-08-29csaf · cert_bundDE
Ein entfernter, anonymer Angreifer kann eine Schwachstelle in libxml2 ausnutzen, um einen Denial of Service Angriff durchzuführen.
- WID-SEC-W-2024-0521IBM MQ: Mehrere SchwachstellenDeutsch2024-02-29csaf · cert_bundDE
Ein entfernter, anonymer Angreifer kann mehrere Schwachstellen in IBM MQ ausnutzen, um beliebigen Programmcode auszuführen, Informationen offenzulegen oder einen Denial of Service Zustand herbeizuführen.
- WID-SEC-W-2024-1248Xerox FreeFlow Print Server: Mehrere SchwachstellenDeutsch2024-05-28csaf · cert_bundDE
Ein Angreifer kann mehrere Schwachstellen in Xerox FreeFlow Print Server ausnutzen, um die Vertraulichkeit, Verfügbarkeit und Integrität des Systems zu gefährden
- WID-SEC-W-2024-2100IBM Power Hardware Management Console: Mehrere SchwachstellenDeutsch2024-09-10csaf · cert_bundDE
Ein Angreifer kann mehrere Schwachstellen in IBM Power Hardware Management Console ausnutzen, um beliebigen Programmcode auszuführen, einen Denial-of-Service-Zustand zu erzeugen und vertrauliche Informationen preiszugeben.
- ICSA-23-348-10Siemens SIMATIC S7-15002023-12-12icsa · cisa_csaf_otUS
Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the firmware version >= V3.1.0 and < V3.1.5 for the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP (incl. SIPLUS variant). These GNU/Linux vulnerabilities have been externally identified. Siemens has released new versions for the affected products and recommends to update to the latest versions. Note: This SSA advises vulnerabilities for firmware version V3.1 only; for versions < V3.1 refer to Siemens Security Bulletin SSB-439005 ( https://cert-portal.siemens.com/productcert/html/ssb-439005.html).
- ICSA-24-165-04Siemens ST7 ScadaConnect2024-06-11icsa · cisa_csaf_otUS
Siemens has released a new version for ST7 ScadaConnect and recommends to update to the latest version.
- ICSA-24-228-06Siemens SINEC NMS2024-08-13icsa · cisa_csaf_otUS
SINEC NMS before V3.0 is affected by multiple vulnerabilities. Siemens has released a new version for SINEC NMS and recommends to update to the latest version.
auch bekannt als (4)
Weitere Namen und Kennungen dieser Entität.
quellen
Welche Quellen diesen Datensatz belegen und wann.
Referenzen (12)
Externe Belege — Patches, Meldungen, Analysen.
- https://cxsecurity.com/cveshow/CVE-2023-39615/cnnvd
- https://gitlab.gnome.org/GNOME/libxml2/-/issues/535cnnvd
- https://packetstormsecurity.com/files/176457/Red-Hat-Security-Advisory-2024-0119-03.htmlcnnvd
- https://www.auscert.org.au/bulletins/ESB-2023.5349cnnvd
- https://www.auscert.org.au/bulletins/ESB-2023.7399cnnvd
- https://gitlab.gnome.org/GNOME/libxml2/-/issues/535enisa_euvd
- https://cert-portal.siemens.com/productcert/html/ssa-341067.htmlnvd
- https://cert-portal.siemens.com/productcert/html/ssa-398330.htmlnvd
Angreifer nutzen Schwachstellen wie diese gegen im Internet exponierte Dienste aus. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.
Kostenloser Scan