CVE-2023-38545
criticalPriorität · beachten · 77EPSS 0.787 · 100. PerzentilExploit · PoCDEEUNLRUUSEPSS · bewertet 2026-10-22
This flaw makes curl overflow a heap based buffer in the SOCKS5 proxy handshake. When curl is asked to pass along the host name to the SOCKS5 proxy to allow that to resolve the address instead of it getting done by curl itself, the maximum length that host name can be is 255 bytes. If the host name is detected to be longer, curl switches to local name resolving and instead passes on the resolved address only. Due to this bug, the local variable that means "let the host resolve the name" could get the wrong value during a slow SOCKS5 handshake, and contrary to the intention, copy the too long host name to the target buffer instead of copying just the resolved address there. The target buffer being a heap based buffer, and the host name coming from the URL that curl has been told to operate with.
Behebungen
Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.
Ein Hersteller-Fix ist verfügbar.
- BehobenSIMATIC RTLS Locating Manager (6GT2780-0DA00)siemens_psirt
Update to V3.0.1.1 or later version The update is available from Siemens Online Software Delivery (OSD).
- BehobenSIMATIC RTLS Locating Manager (6GT2780-0DA10)siemens_psirt
Update to V3.0.1.1 or later version The update is available from Siemens Online Software Delivery (OSD).
- BehobenSIMATIC RTLS Locating Manager (6GT2780-0DA20)siemens_psirt
Update to V3.0.1.1 or later version The update is available from Siemens Online Software Delivery (OSD).
- BehobenSIMATIC RTLS Locating Manager (6GT2780-0DA30)siemens_psirt
Update to V3.0.1.1 or later version The update is available from Siemens Online Software Delivery (OSD).
- BehobenSIMATIC RTLS Locating Manager (6GT2780-1EA10)siemens_psirt
Update to V3.0.1.1 or later version The update is available from Siemens Online Software Delivery (OSD).
- BehobenSIMATIC RTLS Locating Manager (6GT2780-1EA20)siemens_psirt
Update to V3.0.1.1 or later version The update is available from Siemens Online Software Delivery (OSD).
- BehobenSIMATIC RTLS Locating Manager (6GT2780-1EA30)siemens_psirt
Update to V3.0.1.1 or later version The update is available from Siemens Online Software Delivery (OSD).
- BehobenDesigo CC family V6siemens_psirt
Apply patch as documented in section 'Additional Information'
- BehobenDesigo CC family V7siemens_psirt
Apply patch as documented in section 'Additional Information'
- BehobenDesigo CC family V8siemens_psirt
Update to V8.0 QU2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109997962/ - BehobenSENTRON Powermanager V6siemens_psirt
Apply patch as documented in section 'Additional Information'
- BehobenSENTRON Powermanager V7siemens_psirt
Apply patch as documented in section 'Additional Information'
- BehobenSENTRON Powermanager V8siemens_psirt
Update to V8.0 QU2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109771760/ - BehobenRUGGEDCOM APE1808siemens_psirt
Update Fortigate NGFW to V7.4.3. Contact customer support to receive patch and update information.
- BehobenSINEC NMSsiemens_psirt
Update to V2.0 SP1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826954/ - Behobenphoenix_contact_psirt
PHOENIX CONTACT strongly recommends affected users to upgrade to CodeMeter V7.60d,which fixes these vulnerabilities. WIBU-SYSTEMS has already published an update forCodeMeter on their homepage. Since this current version of CodeMeter V7.60d has not yetbeen incorporated into Phoenix Contact products, we strongly recommend to download andinstall the current CodeMeter version directly from the WIBU-SYSTEMS homepage.Update Phoenix Contact Activation Wizard to version 1.7 when available. Please check the Phoenix Contact e-Shop for your related Software product regularly.
- Behobentrumpf_psirt
Get the latest version of the TRUMPF License Expert software (V2.1.0) here and install it onall affected servers and workstations.
- Behobenphoenix_contact_psirt
Update to the latest 2024.0.6 LTS Firmware Release. PHOENIX CONTACT recommends to always use an up-to-date version of the PLCnext Engineer.
- BehobenCisco Crosswork Network Change Automationcisco_csaf
Cisco has released software updates that address this vulnerability.
https://software.cisco.com - BehobenCisco Secure Firewall Adaptive Security Appliance (ASA) Softwarecisco_csaf
Cisco has released software updates that address this vulnerability.
https://software.cisco.com - BehobenCisco Secure Network Analyticscisco_csaf
Cisco has released software updates that address this vulnerability.
https://software.cisco.com - BehobenSINEC NMScisa_csaf_ot
Update to V2.0 SP1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826954/ - BehobenRUGGEDCOM APE1808cisa_csaf_ot
Update Fortigate NGFW to V7.4.3. Contact customer support to receive patch and update information.
- BehobenSIMATIC RTLS Locating Manager (6GT2780-0DA00)cisa_csaf_ot
Update to V3.0.1.1 or later version The update is available from Siemens Online Software Delivery (OSD).
- BehobenSIMATIC RTLS Locating Manager (6GT2780-0DA10)cisa_csaf_ot
Update to V3.0.1.1 or later version The update is available from Siemens Online Software Delivery (OSD).
- BehobenSIMATIC RTLS Locating Manager (6GT2780-0DA20)cisa_csaf_ot
Update to V3.0.1.1 or later version The update is available from Siemens Online Software Delivery (OSD).
- BehobenSIMATIC RTLS Locating Manager (6GT2780-0DA30)cisa_csaf_ot
Update to V3.0.1.1 or later version The update is available from Siemens Online Software Delivery (OSD).
- BehobenSIMATIC RTLS Locating Manager (6GT2780-1EA10)cisa_csaf_ot
Update to V3.0.1.1 or later version The update is available from Siemens Online Software Delivery (OSD).
- BehobenSIMATIC RTLS Locating Manager (6GT2780-1EA20)cisa_csaf_ot
Update to V3.0.1.1 or later version The update is available from Siemens Online Software Delivery (OSD).
- BehobenSIMATIC RTLS Locating Manager (6GT2780-1EA30)cisa_csaf_ot
Update to V3.0.1.1 or later version The update is available from Siemens Online Software Delivery (OSD).
- BehobenDesigo CC family V6cisa_csaf_ot
Apply patch as documented in section 'Additional Information'
- BehobenDesigo CC family V7cisa_csaf_ot
Apply patch as documented in section 'Additional Information'
- BehobenDesigo CC family V8cisa_csaf_ot
Update to V8.0 QU2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109997962/ - BehobenSENTRON Powermanager V6cisa_csaf_ot
Apply patch as documented in section 'Additional Information'
- BehobenSENTRON Powermanager V7cisa_csaf_ot
Apply patch as documented in section 'Additional Information'
- BehobenSENTRON Powermanager V8cisa_csaf_ot
Update to V8.0 QU2 or later version
- MitigationSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0)siemens_psirt
Limit access to the interactive shell of the additional GNU/Linux subssytem to trusted personnel only.
- MitigationSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AC0)siemens_psirt
Limit access to the interactive shell of the additional GNU/Linux subssytem to trusted personnel only.
- MitigationSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AB0)siemens_psirt
Limit access to the interactive shell of the additional GNU/Linux subssytem to trusted personnel only.
- MitigationSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AC0)siemens_psirt
Limit access to the interactive shell of the additional GNU/Linux subssytem to trusted personnel only.
- MitigationSIPLUS S7-1500 CPU 1518-4 PN/DP MFP (6AG1518-4AX00-4AC0)siemens_psirt
Limit access to the interactive shell of the additional GNU/Linux subssytem to trusted personnel only.
- MitigationSIMATIC RTLS Locating Manager (6GT2780-0DA00)siemens_psirt
Apply security hardening of the Windows Server, where the RTLS Locating Manager is installed on, in accordance with your corporate security policies or up-to-date hardening guidelines
- MitigationSIMATIC RTLS Locating Manager (6GT2780-0DA10)siemens_psirt
Apply security hardening of the Windows Server, where the RTLS Locating Manager is installed on, in accordance with your corporate security policies or up-to-date hardening guidelines
- MitigationSIMATIC RTLS Locating Manager (6GT2780-0DA20)siemens_psirt
Apply security hardening of the Windows Server, where the RTLS Locating Manager is installed on, in accordance with your corporate security policies or up-to-date hardening guidelines
- MitigationSIMATIC RTLS Locating Manager (6GT2780-0DA30)siemens_psirt
Apply security hardening of the Windows Server, where the RTLS Locating Manager is installed on, in accordance with your corporate security policies or up-to-date hardening guidelines
- MitigationSIMATIC RTLS Locating Manager (6GT2780-1EA10)siemens_psirt
Apply security hardening of the Windows Server, where the RTLS Locating Manager is installed on, in accordance with your corporate security policies or up-to-date hardening guidelines
- MitigationSIMATIC RTLS Locating Manager (6GT2780-1EA20)siemens_psirt
Apply security hardening of the Windows Server, where the RTLS Locating Manager is installed on, in accordance with your corporate security policies or up-to-date hardening guidelines
- MitigationSIMATIC RTLS Locating Manager (6GT2780-1EA30)siemens_psirt
Apply security hardening of the Windows Server, where the RTLS Locating Manager is installed on, in accordance with your corporate security policies or up-to-date hardening guidelines
- Mitigationphoenix_contact_psirt
Disable using a SOCKS5 proxy: The proxy environment variables HTTP_PROXY, HTTPS_PROXY and ALL_PROXYmust not be set to socks5h:// Ensure that CodeMeter is not defined to use the SOCKS5 proxy. The variableProxyServer must not be start with socks5h://. On Windows, the definition of that variable is in the registry (regedit) underHKLM/SOFTWARE/WIBU-SYSTEMS/CodeMeter/Server/CurrentVersion On Mac, the definition of that variable is in the file/Library/Preferences/com.wibu.CodeMeter.Server.ini On Linux, the definition of that variable is in the file/etc/wibu/CodeMeter/Server.ini On Solaris, the definition of that variable is in the file/etc/opt/CodeMeter/Server.iniUse general security best practices to protect systems from local and network attacks likedescribed in the application node AH EN INDUSTRIAL SECURITY.
- Mitigationtrumpf_psirt
CVE-2023-38545 only appears when used together with a SOCKS-5 Proxy. Not using theaffected products via a SOCKS-5 proxy mitigates the vulnerability.
- Mitigationwago_psirt
Disable using a SOCKS5 proxy: The proxy environment variables HTTP_PROXY, HTTPS_PROXY and ALL_PROXY must not be set to socks5h:// Ensure that CodeMeter is not defined to use the SOCKS5 proxy. The variable ProxyServer must not be start with socks5h://. On Windows, the definition of that variable is in the registry (regedit) under HKLM/SOFTWARE/WIBU-SYSTEMS/CodeMeter/Server/CurrentVersion On Mac, the definition of that variable is in the file /Library/Preferences/com.wibu.CodeMeter.Server.ini On Linux, the definition of that variable is in the file /etc/wibu/CodeMeter/Server.ini On Solaris, the definition of that variable is in the file/etc/opt/CodeMeter/Server.ini For further details on risk mitigation and impact of this vulnerability, please refer to the official WIBU-SYSTEMS Product Security Advisories WIBU-231024-01 and WIBU-231017-01 at Website https://www.wibu.com/support/security-advisories.html. Until an update is available for e!COCKPIT and WAGO-I/O-Pro (CODESYS 2.3) we strongly encourage users to update WIBU-SYSTEMS Codemeter by installing the latest available stand-alone WIBU-SYSTEMS Codemeter Version.
- MitigationFactory Talk Activation Managercisa_csaf_ot
Rockwell Automation encourages users to implement their suggested security best practices to minimize risk of the vulnerability.
- MitigationSIMATIC RTLS Locating Manager (6GT2780-0DA00)cisa_csaf_ot
Apply security hardening of the Windows Server, where the RTLS Locating Manager is installed on, in accordance with your corporate security policies or up-to-date hardening guidelines
- MitigationSIMATIC RTLS Locating Manager (6GT2780-0DA10)cisa_csaf_ot
Apply security hardening of the Windows Server, where the RTLS Locating Manager is installed on, in accordance with your corporate security policies or up-to-date hardening guidelines
- MitigationSIMATIC RTLS Locating Manager (6GT2780-0DA20)cisa_csaf_ot
Apply security hardening of the Windows Server, where the RTLS Locating Manager is installed on, in accordance with your corporate security policies or up-to-date hardening guidelines
- MitigationSIMATIC RTLS Locating Manager (6GT2780-0DA30)cisa_csaf_ot
Apply security hardening of the Windows Server, where the RTLS Locating Manager is installed on, in accordance with your corporate security policies or up-to-date hardening guidelines
- MitigationSIMATIC RTLS Locating Manager (6GT2780-1EA10)cisa_csaf_ot
Apply security hardening of the Windows Server, where the RTLS Locating Manager is installed on, in accordance with your corporate security policies or up-to-date hardening guidelines
- MitigationSIMATIC RTLS Locating Manager (6GT2780-1EA20)cisa_csaf_ot
Apply security hardening of the Windows Server, where the RTLS Locating Manager is installed on, in accordance with your corporate security policies or up-to-date hardening guidelines
- MitigationSIMATIC RTLS Locating Manager (6GT2780-1EA30)cisa_csaf_ot
Apply security hardening of the Windows Server, where the RTLS Locating Manager is installed on, in accordance with your corporate security policies or up-to-date hardening guidelines
- MitigationSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0)cisa_csaf_ot
Limit access to the interactive shell of the additional GNU/Linux subssytem to trusted personnel only.
- MitigationSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AC0)cisa_csaf_ot
Limit access to the interactive shell of the additional GNU/Linux subssytem to trusted personnel only.
- MitigationSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AB0)cisa_csaf_ot
Limit access to the interactive shell of the additional GNU/Linux subssytem to trusted personnel only.
- MitigationSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AC0)cisa_csaf_ot
Limit access to the interactive shell of the additional GNU/Linux subssytem to trusted personnel only.
- MitigationSIPLUS S7-1500 CPU 1518-4 PN/DP MFP (6AG1518-4AX00-4AC0)cisa_csaf_ot
Limit access to the interactive shell of the additional GNU/Linux subssytem to trusted personnel only.
- Kein Fix verfügbarSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0)siemens_psirt
Currently no fix is available
- Kein Fix verfügbarSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AC0)siemens_psirt
Currently no fix is available
- Kein Fix verfügbarSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AB0)siemens_psirt
Currently no fix is available
- Kein Fix verfügbarSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AC0)siemens_psirt
Currently no fix is available
- Kein Fix verfügbarSIPLUS S7-1500 CPU 1518-4 PN/DP MFP (6AG1518-4AX00-4AC0)siemens_psirt
Currently no fix is available
- Kein Fix verfügbarSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0)cisa_csaf_ot
Currently no fix is available
- Kein Fix verfügbarSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AC0)cisa_csaf_ot
Currently no fix is available
- Kein Fix verfügbarSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AB0)cisa_csaf_ot
Currently no fix is available
- Kein Fix verfügbarSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AC0)cisa_csaf_ot
Currently no fix is available
- Kein Fix verfügbarSIPLUS S7-1500 CPU 1518-4 PN/DP MFP (6AG1518-4AX00-4AC0)cisa_csaf_ot
Currently no fix is available
cvss
Technischer Schweregrad, 0–10. Eine Zeile je Quelle.
Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen⚠ Quellen uneinig · high–critical · 7.5–9.8
SSVC
Eine Handlungsentscheidung — aus Ausnutzung und Auswirkung.
schwächen
Die CWE-Schwächeklassen, zu denen dies gehört.
Exploits (8)
Öffentlicher Proof-of-Concept- und Exploit-Code.
- UTsweetyfish/CVE-2023-38545Simple PoC causing overflowPoC · poc_in_github
- Yang-Shun-Yu/CVE-2023-38545Yang-Shun-Yu/CVE-2023-38545PoC · poc_in_github
- dbrugman/CVE-2023-38545-POCCVE-2023-38545 POC for the curl command line toolPoC · poc_in_github
betroffene Produkte (335)
Betroffene Produkte und Versionsbereiche.
- Oracle Fusion Middleware 12.2.1.4.0alle Versionencert_bundDEcpe:/a:oracle:fusion_middleware:12.2.1.4.0
Advisories (31)
Hersteller- und Ökosystem-Meldungen dazu.
- NCSC-2024-0418Kwetsbaarheden verholpen in Oracle AnalyticsNL2024-10-17csaf · ncsc_nlNL
Oracle heeft kwetsbaarheden verholpen in Analytics producten.
- NCSC-2025-0187Kwetsbaarheden verholpen in Siemens productenNL2025-06-10csaf · ncsc_nlNL
Siemens heeft kwetsbaarheden verholpen in diverse producten als RUGGEDCOM, SCALANCE, SIMATIC en Tecnomatix
- NCSC-2026-0051Kwetsbaarheden verholpen in Siemens productenNL2026-02-10csaf · ncsc_nlNL
Siemens heeft kwetsbaarheden verholpen in diverse producten als Desigo, NX, Polarion, SENTRON, Simcenter, SINEC, SIPORT, Siveillance, Solid Edge,
- SSA-082556SSA-082556: Vulnerabilities in the additional GNU/Linux subsystem of the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP V3.1.52025-06-10csaf · siemens_psirtDE
Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the firmware version V3.1.5 for the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP (incl. SIPLUS variant). Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fixes and recommends specific mitigations for products where fixes are not or not yet available. SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP V3.1.5 is no longer maintained and there won't be any update to the CVE list anymore. Please update to the latest version. Note: This SSA advises vulnerabilities for firmware version V3.1.5 only; for version V3.1.6 refer to SSA-019113.
- SSA-093430SSA-093430: Multiple Vulnerabilities in SIMATIC RTLS Locating Manager before V3.02024-05-14csaf · siemens_psirtDE
Siemens has released a new version for SIMATIC RTLS Locating Manager and recommends to update to the latest version.
- SSA-507364SSA-507364: Heap Based Buffer Overflow Vulnerability in WIBU CodeMeter Runtime Affecting the Desigo CC Product Family and SENTRON Powermanager2026-02-10csaf · siemens_psirtDE
Versions V6.0 through V8 QU1 of the Desigo CC product family (Desigo CC, Desigo CC Compact, Desigo CC Connect, Cerberus DMS), as well as the Desigo CC-based SENTRON Powermanager, are affected by a vulnerability in the underlying third-party component WIBU Systems CodeMeter Runtime. Successful exploitation of this vulnerability could lead to code execution in the context of the current process. Siemens has released instructions how to update the CodeMeter Runtime component and recommends to apply the update on affected systems.
- SSA-832273SSA-832273: Multiple Vulnerabilities in Fortigate NGFW Before V7.4.3 on RUGGEDCOM APE1808 Devices2024-03-12csaf · siemens_psirtDE
Fortinet has published information on vulnerabilities in FORTIOS. This advisory lists the related Siemens Industrial products. Siemens has released a new version for RUGGEDCOM APE1808 and recommends to update to the latest version. Siemens is preparing further fix versions and recommends specific countermeasures for products where fixes are not, or not yet available.
- SSA-943925SSA-943925: Multiple Vulnerabilities in SINEC NMS before V2.0 SP12024-02-13csaf · siemens_psirtDE
SINEC NMS before V2.0 SP1 is affected by multiple vulnerabilities. Siemens has released an update for SINEC NMS and recommends to update to the latest version.
- VDE-2023-062Phoenix Contact: WIBU-SYSTEMS CodeMeter Runtime vulnerabilities in multiple products2023-11-21csaf · phoenix_contact_psirtDE
A heap-based buffer overflow caused by libcurl and wrong whitespace character interpretationin Javascript, both used in CodeMeter Runtime affecting multiple products by PHOENIX CONTACT.
- VDE-2024-001TRUMPF: Multiple products contain WIBU CodeMeter vulnerabilities2024-01-29csaf · trumpf_psirtDE
The TRUMPF CAD/CAM software tools mentioned above use the vulnerable CodeMeter Runtime (up to version 7.60d) application from WIBU-SYSTEMS AG to manage licenses within the component TRUMPF License Expert. This CodeMeter application contains new vulnerabilities, which may enable an attacker to gain full access to the server or workstation on which the TRUMPF License Expert has been installed on. A new version of the TRUMPF License Expert which fixes these vulnerabilities is available.
- VDE-2024-007WAGO: WIBU-SYSTEMS CodeMeter Runtime vulnerabilities in multiple products2024-01-22csaf · wago_psirtDE
A heap-based buffer overflow caused by libcurl and wrong whitespace character interpretation in Javascript, both used in CodeMeter Runtime affecting multiple products by WAGO. WIBU-SYSTEMS Codemeter is installed by default during e!COCKPIT and WAGO-I/O-Pro (CODESYS 2.3) installations.
- VDE-2024-073Phoenix Contact: Multiple Vulnerabilities in PLCnext Firmware2024-12-09csaf · phoenix_contact_psirtDE
Multiple Linux component vulnerabilities fixed in latest PLCnext Firmware release 2024.0.6 LTS
- WID-SEC-W-2023-2570cURL: Mehre SchwachstellenDeutsch2023-10-04csaf · cert_bundDE
Ein Angreifer kann mehrere Schwachstellen in cURL und libcurl ausnutzen, um einen nicht näher spezifizierten Angriff zu starten.
- WID-SEC-W-2023-2690Oracle MySQL: Mehrere SchwachstellenDeutsch2023-10-17csaf · cert_bundDE
Ein entfernter, anonymer oder authentisierter Angreifer kann mehrere Schwachstellen in Oracle MySQL ausnutzen, um die Vertraulichkeit, Integrität und Verfügbarkeit zu gefährden.
- WID-SEC-W-2023-2788GitLab: Mehrere SchwachstellenDeutsch2023-10-31csaf · cert_bundDE
Ein Angreifer kann mehrere Schwachstellen in GitLab ausnutzen, um einen Denial of Service Angriff durchzuführen und Informationen offenzulegen.
- WID-SEC-W-2024-0110Oracle Database Server: Mehrere SchwachstellenDeutsch2024-01-16csaf · cert_bundDE
Ein entfernter, authentisierter Angreifer kann mehrere Schwachstellen in Oracle Database Server ausnutzen, um die Integrität und Verfügbarkeit zu gefährden.
- WID-SEC-W-2024-0119Oracle MySQL: Mehrere SchwachstellenDeutsch2024-01-16csaf · cert_bundDE
Ein entfernter, anonymer oder authentisierter Angreifer kann mehrere Schwachstellen in Oracle MySQL ausnutzen, um die Vertraulichkeit, Integrität und Verfügbarkeit zu gefährden.
- WID-SEC-W-2024-0123Oracle Fusion Middleware: Mehrere SchwachstellenDeutsch2024-01-16csaf · cert_bundDE
Ein entfernter, anonymer oder authentisierter Angreifer kann mehrere Schwachstellen in Oracle Fusion Middleware ausnutzen, um die Vertraulichkeit, Integrität und Verfügbarkeit zu gefährden.
- WID-SEC-W-2024-0175Apple macOS: Mehrere SchwachstellenDeutsch2024-01-22csaf · cert_bundDE
Ein entfernter anonymer Angreifer kann mehrere Schwachstellen in Apple macOS ausnutzen, um beliebigen Code auszuführen, Sicherheitsmaßnahmen zu umgehen oder vertrauliche Informationen offenzulegen.
- WID-SEC-W-2024-0178Apple iOS und iPadOS: Mehrere SchwachstellenDeutsch2024-01-22csaf · cert_bundDE
Ein entfernter anonymer Angreifer kann mehrere Schwachstellen in Apple iOS und Apple iPadOS ausnutzen, um beliebigen Code auszuführen oder vertrauliche Informationen offenzulegen.
- WID-SEC-W-2024-0290HCL BigFix: Mehrere SchwachstellenDeutsch2024-02-04csaf · cert_bundDE
Ein entfernter Angreifer kann mehrere Schwachstellen in HCL BigFix ausnutzen, um einen Cross-Site-Scripting-Angriff zu starten, beliebigen Code auszuführen und vertrauliche Informationen offenzulegen.
- WID-SEC-W-2024-0893Oracle PeopleSoft: Mehrere SchwachstellenDeutsch2024-04-16csaf · cert_bundDE
Ein Angreifer kann mehrere Schwachstellen in Oracle PeopleSoft ausnutzen, um die Vertraulichkeit, Integrität und Verfügbarkeit zu gefährden.
- WID-SEC-W-2024-3377Dell PowerProtect Data Domain: Mehrere SchwachstellenDeutsch2024-11-07csaf · cert_bundDE
Ein lokaler Angreifer kann mehrere Schwachstellen in Dell PowerProtect Data Domain ausnutzen, um seine Privilegien zu erhöhen, Informationen offenzulegen und um nicht näher beschriebene Auswirkungen zu erzielen.
- cisco-sa-curl-libcurl-D9ds39cVcURL and libcurl Vulnerability Affecting Cisco Products: October 20232023-10-12csaf · cisco_csafUS
On October 11, 2023, cURL released Version 8.4.0 of the cURL utility and the libcurl library. This release addressed two security vulnerabilities: CVE-2023-38545 – High Security Impact Rating (SIR) CVE-2023-38546 – Low SIR This advisory covers CVE-2023-38545 only. For more information about this vulnerability, see the cURL advisory ["https://curl.se/docs/CVE-2023-38545.html"].
- ICSA-24-004-01Rockwell Automation FactoryTalk Activation2024-01-04icsa · cisa_csaf_otUS
Successful exploitation of these vulnerabilities could result in a buffer overflow and allow the attacker to gain full access to the system.
- ICSA-24-046-15Siemens SINEC NMS2024-02-13icsa · cisa_csaf_otUS
SINEC NMS before V2.0 SP1 is affected by multiple vulnerabilities. Siemens has released an update for SINEC NMS and recommends to update to the latest version.
- ICSA-24-074-05Siemens RUGGEDCOM APE18082024-03-12icsa · cisa_csaf_otUS
Fortinet has published information on vulnerabilities in FORTIOS. This advisory lists the related Siemens Industrial products. Siemens has released a new version for RUGGEDCOM APE1808 and recommends to update to the latest version. Siemens is preparing further fix versions and recommends specific countermeasures for products where fixes are not, or not yet available.
- ICSA-24-137-07Siemens SIMATIC RTLS Locating Manager2024-05-14icsa · cisa_csaf_otUS
Siemens has released a new version for SIMATIC RTLS Locating Manager and recommends to update to the latest version.
- ICSA-25-162-05Siemens SIMATIC S7-1500 CPU family2025-06-10icsa · cisa_csaf_otUS
Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the firmware version V3.1.5 for the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP (incl. SIPLUS variant). Siemens is preparing fix versions and recommends countermeasures for products where fixes are not, or not yet available.
- ICSA-26-043-04Siemens Desigo CC Product Family and SENTRON Powermanager2026-02-10icsa · cisa_csaf_otUS
Versions V6.0 through V8 QU1 of the Desigo CC product family (Desigo CC, Desigo CC Compact, Desigo CC Connect, Cerberus DMS), as well as the Desigo CC-based SENTRON Powermanager, are affected by a vulnerability in the underlying third-party component WIBU Systems CodeMeter Runtime. Successful exploitation of this vulnerability could lead to code execution in the context of the current process. Siemens has released instructions how to update the CodeMeter Runtime component and recommends to apply the update on affected systems.
- CURL-CVE-2023-38545SOCKS5 heap buffer overflow2023-10-11vendor · osvUS
This flaw makes curl overflow a heap based buffer in the SOCKS5 proxy handshake. When curl is asked to pass along the hostname to the SOCKS5 proxy to allow that to resolve the address instead of it getting done by curl itself, the maximum length that hostname can be is 255 bytes. If the hostname is detected to be longer than 255 bytes, curl switches to local name resolving and instead passes on the resolved address only to the proxy. Due to a bug, the local variable that means "let the host resolve the name" could get the wrong value during a slow SOCKS5 handshake, and contrary to the intention, copy the too long hostname to the target buffer instead of copying only the resolved address there.
auch bekannt als (4)
Weitere Namen und Kennungen dieser Entität.
quellen
Welche Quellen diesen Datensatz belegen und wann.
Referenzen (65)
Externe Belege — Patches, Meldungen, Analysen.
- http://seclists.org/fulldisclosure/2024/Jan/34cnnvd
- http://seclists.org/fulldisclosure/2024/Jan/37cnnvd
- http://seclists.org/fulldisclosure/2024/Jan/38cnnvd
- https://access.redhat.com/security/cve/cve-2023-38545cnnvd
- https://curl.se/docs/CVE-2023-38545.htmlcnnvd
- https://cxsecurity.com/cveshow/CVE-2023-38545/cnnvd
- https://forum.vmssoftware.com/viewtopic.php?f=8&t=8868cnnvd
- https://github.com/curl/curl/commit/fb4415d8aee6c1Patchcnnvd
Angreifer nutzen Schwachstellen wie diese gegen im Internet exponierte Dienste aus. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.