CVE-2023-3446
mediumPriorität · verfolgen · 23EPSS 0.065 · 94. PerzentilDEEUNLRUUSEPSS · bewertet 2026-10-23
Issue summary: Checking excessively long DH keys or parameters may be very slow. Impact summary: Applications that use the functions DH_check(), DH_check_ex() or EVP_PKEY_param_check() to check a DH key or DH parameters may experience long delays. Where the key or parameters that are being checked have been obtained from an untrusted source this may lead to a Denial of Service. The function DH_check() performs various checks on DH parameters. One of those checks confirms that the modulus ('p' parameter) is not too large. Trying to use a very large modulus is slow and OpenSSL will not normally use a modulus which is over 10,000 bits in length. However the DH_check() function checks numerous aspects of the key or parameters that have been supplied. Some of those checks use the supplied modulus value even if it has already been found to be too large. An application that calls DH_check() and supplies a key or parameters obtained from an untrusted source could be vulernable to a Denial of Service attack. The function DH_check() is itself called by a number of other OpenSSL functions. An application calling any of those other functions may similarly be affected. The other functions affected by this are DH_check_ex() and EVP_PKEY_param_check(). Also vulnerable are the OpenSSL dhparam and pkeyparam command line applications when using the '-check' option. The OpenSSL SSL/TLS implementation is not affected by this issue. The OpenSSL 3.0 and 3.1 FIPS providers are not affected by this issue.
Behebungen
Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.
Ein Hersteller-Fix ist verfügbar.
- BehobenSIMATIC MV500 familysiemens_psirt
Update to V3.3.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825816/ - BehobenSIDIS Primesiemens_psirt
Update to V4.0.700 or later version
- BehobenST7 ScadaConnect (6NH7997-5DA10-0AA0)siemens_psirt
Update to V1.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955597/ - BehobenSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0)siemens_psirt
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AC0)siemens_psirt
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AB0)siemens_psirt
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AC0)siemens_psirt
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1518-4 PN/DP MFP (6AG1518-4AX00-4AC0)siemens_psirt
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenTeleControl Server Basic V3siemens_psirt
Update to V3.1.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955177/ - BehobenSCALANCE WAB762-1 (6GK5762-1AJ00-6AA0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WAM763-1 (6GK5763-1AL00-7DA0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WAM763-1 (ME) (6GK5763-1AL00-7DC0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WAM763-1 (US) (6GK5763-1AL00-7DB0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WAM766-1 (6GK5766-1GE00-7DA0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WAM766-1 (ME) (6GK5766-1GE00-7DC0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WAM766-1 EEC (ME) (6GK5766-1GE00-7TC0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WUB762-1 (6GK5762-1AJ00-1AA0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WUB762-1 iFeatures (6GK5762-1AJ00-2AA0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WUM763-1 (6GK5763-1AL00-3AA0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WUM763-1 (6GK5763-1AL00-3DA0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WUM763-1 (US) (6GK5763-1AL00-3AB0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WUM763-1 (US) (6GK5763-1AL00-3DB0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WUM766-1 (6GK5766-1GE00-3DA0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WUM766-1 (ME) (6GK5766-1GE00-3DC0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSIMATIC S7-1500 TM MFP - GNU/Linux subsystemsiemens_psirt
Update to V1.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109827684/ - BehobenSINEC INSsiemens_psirt
Update to V1.0 SP2 Update 3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109975745/ - BehobenSINEC NMSsiemens_psirt
Update to V2.0 SP1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826954/ - BehobenSIMATIC S7-1500 TM MFP - GNU/Linux subsystemcisa_csaf_ot
Update to V1.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109827684/ - BehobenSIMATIC MV500 familycisa_csaf_ot
Update to V3.3.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825816/ - BehobenSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0)cisa_csaf_ot
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AC0)cisa_csaf_ot
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AB0)cisa_csaf_ot
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AC0)cisa_csaf_ot
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSIPLUS S7-1500 CPU 1518-4 PN/DP MFP (6AG1518-4AX00-4AC0)cisa_csaf_ot
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - BehobenSINEC NMScisa_csaf_ot
Update to V2.0 SP1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826954/ - BehobenST7 ScadaConnect (6NH7997-5DA10-0AA0)cisa_csaf_ot
Update to V1.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955597/ - BehobenSINEC INScisa_csaf_ot
Update to V1.0 SP2 Update 3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109975745/ - BehobenSCALANCE WAB762-1 (6GK5762-1AJ00-6AA0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WAM763-1 (6GK5763-1AL00-7DA0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WAM763-1 (ME) (6GK5763-1AL00-7DC0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WAM763-1 (US) (6GK5763-1AL00-7DB0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WAM766-1 (6GK5766-1GE00-7DA0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WAM766-1 (ME) (6GK5766-1GE00-7DC0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WAM766-1 EEC (ME) (6GK5766-1GE00-7TC0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WUB762-1 (6GK5762-1AJ00-1AA0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WUB762-1 iFeatures (6GK5762-1AJ00-2AA0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WUM763-1 (6GK5763-1AL00-3AA0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WUM763-1 (6GK5763-1AL00-3DA0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WUM763-1 (US) (6GK5763-1AL00-3AB0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WUM763-1 (US) (6GK5763-1AL00-3DB0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WUM766-1 (6GK5766-1GE00-3DA0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WUM766-1 (ME) (6GK5766-1GE00-3DC0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - BehobenSIDIS Primecisa_csaf_ot
Update to V4.0.700 or later version
- MitigationSIMATIC S7-1500 TM MFP - GNU/Linux subsystemsiemens_psirt
Only build and run applications from trusted sources
- MitigationSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0)cisa_csaf_ot
Only build and run applications from trusted sources.
- MitigationSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AC0)cisa_csaf_ot
Only build and run applications from trusted sources.
- MitigationSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AB0)cisa_csaf_ot
Only build and run applications from trusted sources.
- MitigationSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AC0)cisa_csaf_ot
Only build and run applications from trusted sources.
- MitigationSIPLUS S7-1500 CPU 1518-4 PN/DP MFP (6AG1518-4AX00-4AC0)cisa_csaf_ot
Only build and run applications from trusted sources.
- WorkaroundSIMATIC S7-1500 TM MFP - GNU/Linux subsystemcisa_csaf_ot
Only build and run applications from trusted sources
cvss
Technischer Schweregrad, 0–10. Eine Zeile je Quelle.
Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen⚠ Quellen uneinig · medium–high · 4.9–7.8
SSVC
Eine Handlungsentscheidung — aus Ausnutzung und Auswirkung.
schwächen
Die CWE-Schwächeklassen, zu denen dies gehört.
betroffene Produkte (285)
Betroffene Produkte und Versionsbereiche.
- Red Hat Enterprise Linux Advanced Cluster Security for Kubernetes 4alle Versionencert_bundDEcpe:/o:redhat:enterprise_linux:advanced_cluster_security_for_kubernetes_4
- Red Hat OpenShift CodeReady Workspacesalle Versionencert_bundDEcpe:/a:redhat:openshift:codeready_workspaces
- Red Hat OpenShift Custom Metric Autoscaler 2alle Versionencert_bundDEcpe:/a:redhat:openshift:custom_metric_autoscaler_2
- Red Hat OpenShift Kube Descheduler Operator 5alle Versionencert_bundDEcpe:/a:redhat:openshift:kube_descheduler_operator_5
Advisories (30)
Hersteller- und Ökosystem-Meldungen dazu.
- NCSC-2024-0246Kwetsbaarheden verholpen in Siemens productenNL2024-06-11csaf · ncsc_nlNL
Siemens heeft kwetsbaarheden verholpen in diverse producten, zoals SCALANCE, SICAM, Tecnomatix, SITOP en PowerSys.
- NCSC-2024-0433Kwetsbaarheden verholpen in Siemens productenNL2024-11-12csaf · ncsc_nlNL
Siemens heeft kwetsbaarheden verholpen in diverse producten als Mendix, RUGGEDCOM, SCALANCE, SIMATIC en SINEC.
- NCSC-2025-0061Kwetsbaarheden verholpen in Siemens productenNL2025-02-14csaf · ncsc_nlNL
Siemens heeft kwetsbaarheden verholpen in diverse producten als APOGEE, Opcenter, RUGGEDCOM, SCALANCE, SIMATIC, SIPROTEC en Teamcenter.
- NCSC-2025-0106Kwetsbaarheden verholpen in Siemens productenNL2025-04-08csaf · ncsc_nlNL
Siemens heeft kwetsbaarheden verholpen in diverse producten als Industrial Edge Devices, Mendix, SENTRON, SIDIS, SIMATIC, SIPLUS,Insights Hub Private Cloud, Siemens License Server en Solid Edge.
- SSA-099606SSA-099606: Multiple Vulnerabilities in SIMATIC MV500 before V3.3.52023-11-14csaf · siemens_psirtDE
SIMATIC MV500 before V3.3.5 is affected by multiple vulnerabilities. Siemens has released an update for SIMATIC MV500 and recommends to update to the latest version.
- SSA-277137SSA-277137: Multiple Vulnerabilities in SIDIS Prime Before V4.0.7002025-04-08csaf · siemens_psirtDE
SIDIS Prime before V4.0.700 is affected by multiple vulnerabilities in the components OpenSSL, SQLite, Boost C++ Libraries and several Microsoft components as described below. Siemens has released a new version of SIDIS Prime and recommends to update to the latest version.
- SSA-341067SSA-341067: Multiple vulnerabilities in third-party components in ST7 ScadaConnect before V1.12024-06-11csaf · siemens_psirtDE
Siemens has released a new version for ST7 ScadaConnect and recommends to update to the latest version.
- SSA-398330SSA-398330: Vulnerabilities in the additional GNU/Linux subsystem of the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP >= V3.1.0 and < V3.1.52023-12-12csaf · siemens_psirtDE
Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the firmware version >= V3.1.0 and < V3.1.5 for the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP (incl. SIPLUS variant). These GNU/Linux vulnerabilities have been externally identified. Siemens has released new versions for the affected products and recommends to update to the latest versions. SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP >= V3.1.0 and < V3.1.5 are no longer maintained and there won't be any update to the CVE list anymore. Please update to the latest version. Note: This SSA advises vulnerabilities for firmware version V3.1 only; for versions < V3.1 refer to Siemens Security Bulletin SSB-439005 (https://cert-portal.siemens.com/productcert/html/ssb-439005.html).
- SSA-556635SSA-556635: Multiple Vulnerabilities in Telecontrol Server Basic before V3.1.2.02024-04-09csaf · siemens_psirtDE
Siemens has released a new version for Telecontrol Server Basic that fixes multiple vulnerabilities.
- SSA-769027SSA-769027: Multiple Vulnerabilities fixed in SCALANCE W700 IEEE 802.11ax devices before V3.0.02025-02-11csaf · siemens_psirtDE
SCALANCE W-700 IEEE 802.11ax family devices are affected by multiple vulnerabilities. Siemens has released new versions for the affected products and recommends to update to the latest versions.
- SSA-794697SSA-794697: Vulnerabilities in the Additional GNU/Linux Subsystem of the SIMATIC S7-1500 TM MFP Before V1.12023-06-13csaf · siemens_psirtDE
Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the SIMATIC S7-1500 TM MFP V1.0. Siemens has released a new version for SIMATIC S7-1500 TM MFP - GNU/Linux subsystem and recommends to update to the latest version. SIMATIC S7-1500 TM MFP V1.0 is no longer maintained and there won't be any update to the CVE list anymore. Please update to the latest version. This advisory lists vulnerabilities for firmware version V1.0 only; for V1.1 refer to Siemens Security Advisory SSA-265688 (https://cert-portal.siemens.com/productcert/html/ssa-265688.html).
- SSA-915275SSA-915275: Multiple Vulnerabilities in SINEC INS Before V1.0 SP2 Update 32024-11-12csaf · siemens_psirtDE
SINEC INS before V1.0 SP2 Update 3 is affected by multiple vulnerabilities. Siemens has released a new version for SINEC INS and recommends to update to the latest version.
- SSA-943925SSA-943925: Multiple Vulnerabilities in SINEC NMS before V2.0 SP12024-02-13csaf · siemens_psirtDE
SINEC NMS before V2.0 SP1 is affected by multiple vulnerabilities. Siemens has released an update for SINEC NMS and recommends to update to the latest version.
- WID-SEC-W-2023-1833OpenSSL: Schwachstelle ermöglicht Denial of ServiceDeutsch2023-07-19csaf · cert_bundDE
Ein entfernter, anonymer Angreifer kann eine Schwachstelle in OpenSSL ausnutzen, um einen Denial of Service Angriff durchzuführen.
- WID-SEC-W-2023-2964Splunk Enterprise: Mehrere SchwachstellenDeutsch2023-11-16csaf · cert_bundDE
Ein Angreifer kann mehrere Schwachstellen in Splunk Splunk Enterprise ausnutzen, um einen Cross-Site Scripting Angriff durchzuführen, um Code auszuführen und um nicht näher spezifizierte Auswirkungen zu erzielen.
- WID-SEC-W-2024-0053Dell BIOS: Mehrere SchwachstellenDeutsch2024-01-09csaf · cert_bundDE
Ein Angreifer kann mehrere Schwachstellen im Dell BIOS ausnutzen, um vertrauliche Informationen offenzulegen, Dateien zu manipulieren oder einen Denial-of-Service-Zustand auszulösen.
- WID-SEC-W-2024-0064Juniper Produkte: Mehrere SchwachstellenDeutsch2024-01-10csaf · cert_bundDE
Ein Angreifer aus dem angrenzenden Netzwerk oder ein entfernter, anonymer, authentisierter, lokaler oder physischer Angreifer kann mehrere Schwachstellen in Juniper JUNOS, Juniper JUNOS Evolved, Juniper SRX Series, Juniper EX Series, Juniper QFX Series, Juniper ACX Series, Juniper PTX Series und Juniper MX Series ausnutzen, um beliebigen Code auszuführen, Sicherheitsmaßnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuführen und seine Berechtigungen zu erweitern.
- WID-SEC-W-2024-1226Red Hat OpenShift: Mehrere SchwachstellenDeutsch2024-05-22csaf · cert_bundDE
Ein Angreifer kann mehrere Schwachstellen in Red Hat OpenShift ausnutzen, um Dateien zu manipulieren, einen Denial-of-Service-Zustand zu verursachen, beliebigen Code auszuführen, vertrauliche Informationen offenzulegen, seine Privilegien zu erweitern oder um weitere nicht spezifizierte Angriffe auszuführen.
- WID-SEC-W-2024-1307Red Hat OpenShift Service Mesh Containers: Mehrere SchwachstellenDeutsch2024-06-06csaf · cert_bundDE
Ein Angreifer kann mehrere Schwachstellen in Red Hat OpenShift Service Mesh Containers ausnutzen, um Dateien zu manipulieren, einen 'Denial of Service'-Zustand erzuegen, beliebigen Code auszuführen, vertrauliche Informationen offenzulegen oder weitere nicht spezifizierte Angriffe durchzuführen.
- WID-SEC-W-2024-1488IBM InfoSphere Information Server: Mehrere SchwachstellenDeutsch2024-06-30csaf · cert_bundDE
Ein entfernter Angreifer kann mehrere Schwachstellen in IBM InfoSphere Information Server ausnutzen, um beliebigen Programmcode auszuführen, einen Cross-Site-Scripting-Angriff durchzuführen, Sicherheitsmaßnahmen zu umgehen, einen Denial-of-Service-Zustand zu erzeugen und vertrauliche Informationen offenzulegen.
- WID-SEC-W-2024-1591Juniper JUNOS: Mehrere SchwachstellenDeutsch2024-07-10csaf · cert_bundDE
Ein Angreifer kann mehrere Schwachstellen in Juniper JUNOS ausnutzen, um einen Denial of Service zu verursachen, Informationen offenzulegen, Privilegien zu erweitern und Sicherheitsmechanismen inklusive zu umgehen.
- WID-SEC-W-2024-2100IBM Power Hardware Management Console: Mehrere SchwachstellenDeutsch2024-09-10csaf · cert_bundDE
Ein Angreifer kann mehrere Schwachstellen in IBM Power Hardware Management Console ausnutzen, um beliebigen Programmcode auszuführen, einen Denial-of-Service-Zustand zu erzeugen und vertrauliche Informationen preiszugeben.
- ICSA-23-166-11Siemens SIMATIC S7-1500 TM MFP Linux Kernel2023-06-13icsa · cisa_csaf_otUS
Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the SIMATIC S7-1500 TM MFP V1.0. Siemens has released a new version for SIMATIC S7-1500 TM MFP - GNU/Linux subsystem and recommends to update to the latest version. This advisory lists vulnerabilities for firmware version V1.0 only; for V1.1 refer to Siemens Security Advisory SSA-265688 ( https://cert-portal.siemens.com/productcert/html/ssa-265688.html).
- ICSA-23-320-13Siemens SIMATIC MV5002023-11-14icsa · cisa_csaf_otUS
SIMATIC MV500 before V3.3.5 is affected by multiple vulnerabilities. Siemens has released an update for SIMATIC MV500 and recommends to update to the latest version.
- ICSA-23-348-10Siemens SIMATIC S7-15002023-12-12icsa · cisa_csaf_otUS
Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the firmware version >= V3.1.0 and < V3.1.5 for the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP (incl. SIPLUS variant). These GNU/Linux vulnerabilities have been externally identified. Siemens has released new versions for the affected products and recommends to update to the latest versions. Note: This SSA advises vulnerabilities for firmware version V3.1 only; for versions < V3.1 refer to Siemens Security Bulletin SSB-439005 ( https://cert-portal.siemens.com/productcert/html/ssb-439005.html).
- ICSA-24-046-15Siemens SINEC NMS2024-02-13icsa · cisa_csaf_otUS
SINEC NMS before V2.0 SP1 is affected by multiple vulnerabilities. Siemens has released an update for SINEC NMS and recommends to update to the latest version.
- ICSA-24-165-04Siemens ST7 ScadaConnect2024-06-11icsa · cisa_csaf_otUS
Siemens has released a new version for ST7 ScadaConnect and recommends to update to the latest version.
- ICSA-24-319-08Siemens SINEC INS2024-11-12icsa · cisa_csaf_otUS
SINEC INS before V1.0 SP2 Update 3 is affected by multiple vulnerabilities. Siemens has released a new version for SINEC INS and recommends to update to the latest version.
- ICSA-25-044-09Siemens SCALANCE W700 IEEE 802.11ax2025-02-11icsa · cisa_csaf_otUS
SCALANCE W-700 IEEE 802.11ax family devices are affected by multiple vulnerabilities. Siemens has released new versions for the affected products and recommends to update to the latest versions.
- ICSA-25-100-02Siemens SIDIS Prime2025-04-08icsa · cisa_csaf_otUS
SIDIS Prime before V4.0.700 is affected by multiple vulnerabilities in the components OpenSSL, SQLite, Boost C++ Libraries and several Microsoft components as described below. Siemens has released a new version of SIDIS Prime and recommends to update to the latest version.
auch bekannt als (4)
Weitere Namen und Kennungen dieser Entität.
quellen
Welche Quellen diesen Datensatz belegen und wann.
Referenzen (49)
Externe Belege — Patches, Meldungen, Analysen.
- http://www.openwall.com/lists/oss-security/2023/07/19/4cnnvd
- http://www.openwall.com/lists/oss-security/2023/07/19/5cnnvd
- http://www.openwall.com/lists/oss-security/2023/07/19/6cnnvd
- http://www.openwall.com/lists/oss-security/2023/07/31/1cnnvd
- https://cxsecurity.com/cveshow/CVE-2023-3446/cnnvd
- https://git.openssl.org/gitweb/?p=openssl.git;a=commitdiff;h=1fa20cf2f506113c761777127a38bce5068740ebcnnvd
- https://git.openssl.org/gitweb/?p=openssl.git;a=commitdiff;h=8780a896543a654e757db1b9396383f9d8095528cnnvd
- https://git.openssl.org/gitweb/?p=openssl.git;a=commitdiff;h=9a0a4d3c1e7138915563c0df4fe6a3f9377b839ccnnvd
Angreifer nutzen Schwachstellen wie diese gegen im Internet exponierte Dienste aus. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.
Kostenloser Scan