CVE-2023-29007
highPriorität · verfolgen · 43EPSS 0.056 · 93. PerzentilExploit · PoCCHDEEURUUSEPSS · bewertet 2026-10-27
Git is a revision control system. Prior to versions 2.30.9, 2.31.8, 2.32.7, 2.33.8, 2.34.8, 2.35.8, 2.36.6, 2.37.7, 2.38.5, 2.39.3, and 2.40.1, a specially crafted `.gitmodules` file with submodule URLs that are longer than 1024 characters can used to exploit a bug in `config.c::git_config_copy_or_rename_section_in_file()`. This bug can be used to inject arbitrary configuration into a user's `$GIT_DIR/config` when attempting to remove the configuration section associated with that submodule. When the attacker injects configuration values which specify executables to run (such as `core.pager`, `core.editor`, `core.sshCommand`, etc.) this can lead to a remote code execution. A fix A fix is available in versions 2.30.9, 2.31.8, 2.32.7, 2.33.8, 2.34.8, 2.35.8, 2.36.6, 2.37.7, 2.38.5, 2.39.3, and 2.40.1. As a workaround, avoid running `git submodule deinit` on untrusted repositories or without prior inspection of any submodule sections in `$GIT_DIR/config`.
Behebungen
Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.
Noch kein Hersteller-Fix; eine Mitigation ist verfügbar.
- MitigationARM600abb_psirt
Mitigating factors describe conditions and circumstances that make an attack that exploits the vulnerability difficult or less likely to succeed. The following mitigations are recommended. 1. Obtain a cellular private access point (APN). A dedicated private cellular access point and respective SIM card subscriptions can be requested from your cellular service provider. This service doesn’t expose the traffic between remote sites and main site to the internet but rather uses cellular operator’s private wide area network (WAN). Therefore, the ARM600 wouldn’t need open ports to the internet. 2. Avoid exposing any system component to the internet. If, however, the ARM600 is exposed to the internet, only the VPN port should be opened towards the internet (e.g., Patrol management connections can be configured to use VPN tunnel and remote administration connections can be implemented by using OpenVPN PC-client). 4. Perform firewall configuration by the "allowlisting" principle, i.e., explicitly allowing only the required ports and protocols and blocking any other traffic. 6. If the internet is used as a WAN media for carrying VPN tunnels, use Demilitarized Zone (DMZ) for terminating connections from the internet (i.e., the remote connections should terminate to the DMZ network, which would be segregated from other networks by a firewall. The ARM600 server would be located into this DMZ). 7. Change the default user credentials of ARM600 and Arctic wireless gateways into non-defaults and use complex non-guessable passwords with special characters. Do not reuse passwords within the system. 8. Use administrator (i.e., root user) privileges only when required by the task. 9. Supporting systems, such as PCs used for configuration, should be frequently updated. If possible, use dedicated site PCs for upgrading and engineering purposes. At minimum, PCs should be investigated by running a full virus scan with recently updated signature files before introducing the PC to the OT system. Any data, such as device configurations and firmware update files transferred to the Arctic system should be virus scanned prior to transferring. 10. Introduce a backup policy, which will ensure periodical backups and backup revision numbering. Consider the following: a. Check that the entire system has backups available from all applicable parts. b. Store the backups in a safe place (e.g. in an encrypted storage), restricted by role-based access control mechanisms. c. Ensure the security of the configuration PCs that may have local copies of device configurations. d. Validate the backups to make sure that they’re working. 11. Follow cyber security best practices for installation, operation, and decommissioning as described in the product’s Cyber Security Deployment Guideline and User Manual. 12. Use continuous monitoring (e.g., intrusion detection/prevention tools) to detect anomalies in the system 13. Consider hardening the system according to the following: a. Remove any unnecessary communication links in the system. b. If possible, close unused physical ports. c. Open only the necessary TCP/UDP ports in the configuration. d. Remove all unnecessary user accounts. e. Restrict traffic by firewall. f. Allow the traffic only from/to necessary hosts' IP addresses (i.e., define both source and destination in the firewall rules, where possible). g. Define client IP address as allowed address in SCADA communication protocols, if such configuration is supported. h. Remove or deactivate all unused processes, communication ports and services, where possible. i. Use physical access controls to the system installations (e.g., to server rooms and device cabinets).
- MitigationSWabb_psirt
Mitigating factors describe conditions and circumstances that make an attack that exploits the vulnerability difficult or less likely to succeed. The following mitigations are recommended. 1. Obtain a cellular private access point (APN). A dedicated private cellular access point and respective SIM card subscriptions can be requested from your cellular service provider. This service doesn’t expose the traffic between remote sites and main site to the internet but rather uses cellular operator’s private wide area network (WAN). Therefore, the ARM600 wouldn’t need open ports to the internet. 2. Avoid exposing any system component to the internet. If, however, the ARM600 is exposed to the internet, only the VPN port should be opened towards the internet (e.g., Patrol management connections can be configured to use VPN tunnel and remote administration connections can be implemented by using OpenVPN PC-client). 4. Perform firewall configuration by the "allowlisting" principle, i.e., explicitly allowing only the required ports and protocols and blocking any other traffic. 6. If the internet is used as a WAN media for carrying VPN tunnels, use Demilitarized Zone (DMZ) for terminating connections from the internet (i.e., the remote connections should terminate to the DMZ network, which would be segregated from other networks by a firewall. The ARM600 server would be located into this DMZ). 7. Change the default user credentials of ARM600 and Arctic wireless gateways into non-defaults and use complex non-guessable passwords with special characters. Do not reuse passwords within the system. 8. Use administrator (i.e., root user) privileges only when required by the task. 9. Supporting systems, such as PCs used for configuration, should be frequently updated. If possible, use dedicated site PCs for upgrading and engineering purposes. At minimum, PCs should be investigated by running a full virus scan with recently updated signature files before introducing the PC to the OT system. Any data, such as device configurations and firmware update files transferred to the Arctic system should be virus scanned prior to transferring. 10. Introduce a backup policy, which will ensure periodical backups and backup revision numbering. Consider the following: a. Check that the entire system has backups available from all applicable parts. b. Store the backups in a safe place (e.g. in an encrypted storage), restricted by role-based access control mechanisms. c. Ensure the security of the configuration PCs that may have local copies of device configurations. d. Validate the backups to make sure that they’re working. 11. Follow cyber security best practices for installation, operation, and decommissioning as described in the product’s Cyber Security Deployment Guideline and User Manual. 12. Use continuous monitoring (e.g., intrusion detection/prevention tools) to detect anomalies in the system 13. Consider hardening the system according to the following: a. Remove any unnecessary communication links in the system. b. If possible, close unused physical ports. c. Open only the necessary TCP/UDP ports in the configuration. d. Remove all unnecessary user accounts. e. Restrict traffic by firewall. f. Allow the traffic only from/to necessary hosts' IP addresses (i.e., define both source and destination in the firewall rules, where possible). g. Define client IP address as allowed address in SCADA communication protocols, if such configuration is supported. h. Remove or deactivate all unused processes, communication ports and services, where possible. i. Use physical access controls to the system installations (e.g., to server rooms and device cabinets).
- MitigationARM600cisa_csaf_ot
Mitigating factors describe conditions and circumstances that make an attack that exploits the vulnerability difficult or less likely to succeed. The following mitigations are recommended. 1. Obtain a cellular private access point (APN). A dedicated private cellular access point and respective SIM card subscriptions can be requested from your cellular service provider. This service doesn’t expose the traffic between remote sites and main site to the internet but rather uses cellular operator’s private wide area network (WAN). Therefore, the ARM600 wouldn’t need open ports to the internet. 2. Avoid exposing any system component to the internet. If, however, the ARM600 is exposed to the internet, only the VPN port should be opened towards the internet (e.g., Patrol management connections can be configured to use VPN tunnel and remote administration connections can be implemented by using OpenVPN PC-client). 4. Perform firewall configuration by the "allowlisting" principle, i.e., explicitly allowing only the required ports and protocols and blocking any other traffic. 6. If the internet is used as a WAN media for carrying VPN tunnels, use Demilitarized Zone (DMZ) for terminating connections from the internet (i.e., the remote connections should terminate to the DMZ network, which would be segregated from other networks by a firewall. The ARM600 server would be located into this DMZ). 7. Change the default user credentials of ARM600 and Arctic wireless gateways into non-defaults and use complex non-guessable passwords with special characters. Do not reuse passwords within the system. 8. Use administrator (i.e., root user) privileges only when required by the task. 9. Supporting systems, such as PCs used for configuration, should be frequently updated. If possible, use dedicated site PCs for upgrading and engineering purposes. At minimum, PCs should be investigated by running a full virus scan with recently updated signature files before introducing the PC to the OT system. Any data, such as device configurations and firmware update files transferred to the Arctic system should be virus scanned prior to transferring. 10. Introduce a backup policy, which will ensure periodical backups and backup revision numbering. Consider the following: a. Check that the entire system has backups available from all applicable parts. b. Store the backups in a safe place (e.g. in an encrypted storage), restricted by role-based access control mechanisms. c. Ensure the security of the configuration PCs that may have local copies of device configurations. d. Validate the backups to make sure that they’re working. 11. Follow cyber security best practices for installation, operation, and decommissioning as described in the product’s Cyber Security Deployment Guideline and User Manual. 12. Use continuous monitoring (e.g., intrusion detection/prevention tools) to detect anomalies in the system 13. Consider hardening the system according to the following: a. Remove any unnecessary communication links in the system. b. If possible, close unused physical ports. c. Open only the necessary TCP/UDP ports in the configuration. d. Remove all unnecessary user accounts. e. Restrict traffic by firewall. f. Allow the traffic only from/to necessary hosts' IP addresses (i.e., define both source and destination in the firewall rules, where possible). g. Define client IP address as allowed address in SCADA communication protocols, if such configuration is supported. h. Remove or deactivate all unused processes, communication ports and services, where possible. i. Use physical access controls to the system installations (e.g., to server rooms and device cabinets).
- MitigationSWcisa_csaf_ot
Mitigating factors describe conditions and circumstances that make an attack that exploits the vulnerability difficult or less likely to succeed. The following mitigations are recommended. 1. Obtain a cellular private access point (APN). A dedicated private cellular access point and respective SIM card subscriptions can be requested from your cellular service provider. This service doesn’t expose the traffic between remote sites and main site to the internet but rather uses cellular operator’s private wide area network (WAN). Therefore, the ARM600 wouldn’t need open ports to the internet. 2. Avoid exposing any system component to the internet. If, however, the ARM600 is exposed to the internet, only the VPN port should be opened towards the internet (e.g., Patrol management connections can be configured to use VPN tunnel and remote administration connections can be implemented by using OpenVPN PC-client). 4. Perform firewall configuration by the "allowlisting" principle, i.e., explicitly allowing only the required ports and protocols and blocking any other traffic. 6. If the internet is used as a WAN media for carrying VPN tunnels, use Demilitarized Zone (DMZ) for terminating connections from the internet (i.e., the remote connections should terminate to the DMZ network, which would be segregated from other networks by a firewall. The ARM600 server would be located into this DMZ). 7. Change the default user credentials of ARM600 and Arctic wireless gateways into non-defaults and use complex non-guessable passwords with special characters. Do not reuse passwords within the system. 8. Use administrator (i.e., root user) privileges only when required by the task. 9. Supporting systems, such as PCs used for configuration, should be frequently updated. If possible, use dedicated site PCs for upgrading and engineering purposes. At minimum, PCs should be investigated by running a full virus scan with recently updated signature files before introducing the PC to the OT system. Any data, such as device configurations and firmware update files transferred to the Arctic system should be virus scanned prior to transferring. 10. Introduce a backup policy, which will ensure periodical backups and backup revision numbering. Consider the following: a. Check that the entire system has backups available from all applicable parts. b. Store the backups in a safe place (e.g. in an encrypted storage), restricted by role-based access control mechanisms. c. Ensure the security of the configuration PCs that may have local copies of device configurations. d. Validate the backups to make sure that they’re working. 11. Follow cyber security best practices for installation, operation, and decommissioning as described in the product’s Cyber Security Deployment Guideline and User Manual. 12. Use continuous monitoring (e.g., intrusion detection/prevention tools) to detect anomalies in the system 13. Consider hardening the system according to the following: a. Remove any unnecessary communication links in the system. b. If possible, close unused physical ports. c. Open only the necessary TCP/UDP ports in the configuration. d. Remove all unnecessary user accounts. e. Restrict traffic by firewall. f. Allow the traffic only from/to necessary hosts' IP addresses (i.e., define both source and destination in the firewall rules, where possible). g. Define client IP address as allowed address in SCADA communication protocols, if such configuration is supported. h. Remove or deactivate all unused processes, communication ports and services, where possible. i. Use physical access controls to the system installations (e.g., to server rooms and device cabinets).
cvss
Technischer Schweregrad, 0–10. Eine Zeile je Quelle.
Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen
schwächen
Die CWE-Schwächeklassen, zu denen dies gehört.
Exploits (2)
Öffentlicher Proof-of-Concept- und Exploit-Code.
- ethiack/CVE-2023-29007PoC repository for CVE-2023-29007PoC · poc_in_github
- x-Defender/CVE-2023-29007_win-versionx-Defender/CVE-2023-29007_win-versionPoC · poc_in_github
betroffene Produkte (70)
Betroffene Produkte und Versionsbereiche.
- Xerox FreeFlow Print Server v7 for Solarisalle Versionencert_bundDEcpe:/a:xerox:freeflow_print_server:v7_for_solaris
Advisories (8)
Hersteller- und Ökosystem-Meldungen dazu.
- 2NGA002579ABB Arctic communication solution ARM600 Vulnerabilities2025-04-07csaf · abb_psirtCH
ABB is aware of public reports of a vulnerabilities in product versions listed as affected in this advisory. An attacker who successfully exploited these vulnerabilities could cause the product to stop, make the product inacces-sible, take remote control of the product or insert and run arbitrary code. As part of ABB product lifecycle policy, once a product transitions to end-of-life, we discontinue maintenance, security patches, and technical support to focus on current and future technologies. While the product will continue to function, we strongly recommend implementing mitigations defined in this document, such as using a private APN cellular network between Arctic wireless gateways and ARM600 for establishing VPN tunnels, to mitigate security risks and avoid potential vulnerabilities. As part of ABB product lifecycle policy, once a product transitions to Limited state, we discontinue maintenance, security patches, and technical support to focus on current and future technologies. While the product will continue to function, we strongly recommend implementing mitigations defined in this document to mitigate security risks.
- WID-SEC-W-2023-1072git: Mehrere SchwachstellenDeutsch2023-04-25csaf · cert_bundDE
Ein Angreifer kann mehrere Schwachstellen in git ausnutzen, um Sicherheitsvorkehrungen zu umgehen, Daten zu manipulieren und seine Privilegien zu erweitern.
- WID-SEC-W-2023-1446Microsoft Developer Tools: Mehrere SchwachstellenDeutsch2023-06-13csaf · cert_bundDE
Ein entfernter, anonymer, authentisierter oder lokaler Angreifer kann mehrere Schwachstellen in Microsoft .NET Framework, Microsoft Azure DevOps Server, Microsoft NuGet, Microsoft Visual Studio und Microsoft Visual Studio Code ausnutzen, um beliebigen Code auszuführen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuführen, seine Rechte zu erweitern und Daten zu manipulieren.
- WID-SEC-W-2023-1812Oracle Communications: Mehrere SchwachstellenDeutsch2023-07-18csaf · cert_bundDE
Ein entfernter, anonymer oder authentisierter Angreifer kann mehrere Schwachstellen in Oracle Communications ausnutzen, um die Vertraulichkeit, Integrität und Verfügbarkeit zu gefährden.
- WID-SEC-W-2023-2031Xerox FreeFlow Print Server: Mehrere SchwachstellenDeutsch2023-08-09csaf · cert_bundDE
Ein Angreifer kann mehrere Schwachstellen in Xerox FreeFlow Print Server ausnutzen, um die Vertraulichkeit, Verfügbarkeit und Integrität des Systems zu gefährden.
- WID-SEC-W-2023-2625IBM QRadar SIEM: Mehrere SchwachstellenDeutsch2023-10-10csaf · cert_bundDE
Ein entfernter, anonymer, authentisierter oder lokaler Angreifer kann mehrere Schwachstellen in IBM QRadar SIEM ausnutzen, um beliebigen Code auszuführen, Sicherheitsmaßnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuführen und einen Cross-Site-Scripting-Angriff durchzuführen.
- WID-SEC-W-2024-0794Dell ECS: Mehrere SchwachstellenDeutsch2024-04-04csaf · cert_bundDE
Ein Angreifer kann mehrere Schwachstellen in Dell ECS ausnutzen, um seine Privilegien zu erweitern, beliebigen Programmcode mit Administratorrechten auszuführen, Informationen offenzulegen, Dateien zu manipulieren, einen Cross-Site-Scripting-Angriff durchzuführen, Sicherheitsvorkehrungen zu umgehen oder einen Denial of Service Zustand herbeizuführen.
- ICSA-25-105-08ABB M2M Gateway2025-04-07icsa · cisa_csaf_otUS
ABB is aware of public reports of a vulnerabilities in product versions listed as affected in this advisory. An attacker who successfully exploited these vulnerabilities could cause the product to stop, make the product inacces-sible, take remote control of the product or insert and run arbitrary code. As part of ABB product lifecycle policy, once a product transitions to end-of-life, we discontinue maintenance, security patches, and technical support to focus on current and future technologies. While the product will continue to function, we strongly recommend implementing mitigations defined in this document, such as using a private APN cellular network between Arctic wireless gateways and ARM600 for establishing VPN tunnels, to mitigate security risks and avoid potential vulnerabilities. As part of ABB product lifecycle policy, once a product transitions to Limited state, we discontinue maintenance, security patches, and technical support to focus on current and future technologies. While the product will continue to function, we strongly recommend implementing mitigations defined in this document to mitigate security risks.
auch bekannt als (3)
Weitere Namen und Kennungen dieser Entität.
quellen
Welche Quellen diesen Datensatz belegen und wann.
Referenzen (36)
Externe Belege — Patches, Meldungen, Analysen.
- https://access.redhat.com/security/cve/cve-2023-29007cnnvd
- https://cxsecurity.com/cveshow/CVE-2023-29007/cnnvd
- https://github.com/git/git/blob/9ce9dea4e1c2419cca126d29fa7730baa078a11b/Documentation/RelNotes/2.30.9.txtcnnvd
- https://github.com/git/git/commit/528290f8c61222433a8cf02fb7cfffa8438432b4cnnvd
- https://github.com/git/git/security/advisories/GHSA-v48j-4xgg-4844cnnvd
- https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/PI7FZ4NNR5S5J5K6AMVQBH2JFP6NE4L7/cnnvd
- https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/RKOXOAZ42HLXHXTW6JZI4L5DAIYDTYCU/cnnvd
- https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/YFZWGQKB6MM5MNF2DLFTD7KS2KWPICKL/cnnvd
Angreifer nutzen Schwachstellen wie diese gegen im Internet exponierte Dienste aus. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.
Kostenloser Scan