CVE-2023-2639

mediumPriorität · verfolgen · 19EPSS 0.004 · 32. PerzentilEURUUS
grimoire priorityP3 · Track
Exploitable?
—
no known exploitation
Likely / severe?
0.38% (32nd) EPSS
CVSS 4.7 · medium
Is it mine?
9 products
Prüfe deine Angriffsfläche
Who says so?
5 sources
cnnvd · enisa_euvd · fstec_bdu · cisa_csaf_ot

EPSS · bewertet 2026-10-27

The underlying feedback mechanism of Rockwell Automation's FactoryTalk System Services that transfers the FactoryTalk Policy Manager rules to relevant devices on the network does not verify that the origin of the communication is from a legitimate local client device.  This may allow a threat actor to craft a malicious website that, when visited, will send a malicious script that can connect to the local WebSocket endpoint and wait for events as if it was a valid client device. If successfully exploited, this would allow a threat actor to receive information including whether FactoryTalk Policy Manager is installed and potentially the entire security policy. 

01

Behebungen

Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.

Ein Hersteller-Fix ist verfügbar.

02

cvss

Technischer Schweregrad, 0–10. Eine Zeile je Quelle.

4.7
010

Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen

v3.14.7mediumCVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:N/A:Nprimary · NVD / NIST USAusnutzbarkeit 2.8 · Auswirkung 1.4
v3.04.1mediumCVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:N/A:Nsecondary · CISA US
v3.14.1mediumAV:N/AC:L/PR:L/UI:R/S:C/C:L/I:N/A:Nsecondary · FSTEC (BDU) RU
v3.14.1mediumCVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:N/A:Nsecondary · ENISA EU
v3.14.1mediumCVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:N/A:Nsecondary · PSIRT@rockwellautomation.comAusnutzbarkeit 2.3 · Auswirkung 1.4
v3.14.3mediumCVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:N/A:N/E:Usecondary · CVSS-BT (t0sche)
03

SSVC

Eine Handlungsentscheidung — aus Ausnutzung und Auswirkung.

Exploitation: none · Automatable: no · Technical Impact: totalcoordinatorcisa_ssvcUS
04

schwächen

Die CWE-Schwächeklassen, zu denen dies gehört.

05

betroffene Produkte (9)

Betroffene Produkte und Versionsbereiche.

06

Advisories (1)

Hersteller- und Ökosystem-Meldungen dazu.

  • ICSA-23-164-02Rockwell Automation FactoryTalk Services Platform2023-06-13icsa · cisa_csaf_otUS

    Successful exploitation of these vulnerabilities could allow an attacker to disclose information, load malicious configuration files, or elevate privileges from a user to an administrator.

07

auch bekannt als (4)

Weitere Namen und Kennungen dieser Entität.

08

quellen

Welche Quellen diesen Datensatz belegen und wann.

veröffentlicht 2023-06-13geändert 2026-06-17
10

Referenzen (4)

Externe Belege — Patches, Meldungen, Analysen.

scry

Angreifer nutzen Schwachstellen wie diese gegen im Internet exponierte Dienste aus. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.

Kostenloser Scan