CVE-2023-22490
mediumPriorität · verfolgen · 32EPSS 0.007 · 53. PerzentilExploit · PoCDEEURUUSEPSS · bewertet 2026-10-27
Git is a revision control system. Using a specially-crafted repository, Git prior to versions 2.39.2, 2.38.4, 2.37.6, 2.36.5, 2.35.7, 2.34.7, 2.33.7, 2.32.6, 2.31.7, and 2.30.8 can be tricked into using its local clone optimization even when using a non-local transport. Though Git will abort local clones whose source `$GIT_DIR/objects` directory contains symbolic links, the `objects` directory itself may still be a symbolic link. These two may be combined to include arbitrary files based on known paths on the victim's filesystem within the malicious repository's working copy, allowing for data exfiltration in a similar manner as CVE-2022-39253. A fix has been prepared and will appear in v2.39.2 v2.38.4 v2.37.6 v2.36.5 v2.35.7 v2.34.7 v2.33.7 v2.32.6, v2.31.7 and v2.30.8. If upgrading is impractical, two short-term workarounds are available. Avoid cloning repositories from untrusted sources with `--recurse-submodules`. Instead, consider cloning repositories without recursively cloning their submodules, and instead run `git submodule update` at each layer. Before doing so, inspect each new `.gitmodules` file to ensure that it does not contain suspicious module URLs.
Behebungen
Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.
Ein Hersteller-Fix ist verfügbar.
- BehobenSCALANCE XCH328 (6GK5328-4TS01-2EC2)siemens_psirt
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - BehobenSCALANCE XCM324 (6GK5324-8TS01-2AC2)siemens_psirt
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - BehobenSCALANCE XCM328 (6GK5328-4TS01-2AC2)siemens_psirt
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - BehobenSCALANCE XCM332 (6GK5332-0GA01-2AC2)siemens_psirt
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - BehobenSCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)siemens_psirt
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - BehobenSCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)siemens_psirt
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - BehobenSCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)siemens_psirt
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - BehobenSCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)siemens_psirt
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - BehobenSCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)siemens_psirt
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - BehobenSCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)siemens_psirt
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - BehobenSCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)siemens_psirt
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - BehobenSCALANCE XCH328 (6GK5328-4TS01-2EC2)cisa_csaf_ot
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - BehobenSCALANCE XCM324 (6GK5324-8TS01-2AC2)cisa_csaf_ot
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - BehobenSCALANCE XCM328 (6GK5328-4TS01-2AC2)cisa_csaf_ot
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - BehobenSCALANCE XCM332 (6GK5332-0GA01-2AC2)cisa_csaf_ot
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - BehobenSCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)cisa_csaf_ot
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - BehobenSCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)cisa_csaf_ot
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - BehobenSCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)cisa_csaf_ot
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - BehobenSCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)cisa_csaf_ot
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - BehobenSCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)cisa_csaf_ot
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - BehobenSCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)cisa_csaf_ot
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - BehobenSCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)cisa_csaf_ot
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/
cvss
Technischer Schweregrad, 0–10. Eine Zeile je Quelle.
Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen
SSVC
Eine Handlungsentscheidung — aus Ausnutzung und Auswirkung.
schwächen
Die CWE-Schwächeklassen, zu denen dies gehört.
Exploits (1)
Öffentlicher Proof-of-Concept- und Exploit-Code.
- smash8tap/CVE-2023-22490_PoCsmash8tap/CVE-2023-22490_PoCPoC · poc_in_github
betroffene Produkte (77)
Betroffene Produkte und Versionsbereiche.
- IBM InfoSphere Information Serveralle Versionencert_bundDEcpe:/a:ibm:infosphere_information_server:-
Advisories (5)
Hersteller- und Ökosystem-Meldungen dazu.
- SSA-806742SSA-806742: Multiple Vulnerabilities in SCALANCE XCM-/XRM-300 before V2.42024-02-13csaf · siemens_psirtDE
SCALANCE XCM-/XRM-300 before V2.4 is affected by multiple vulnerabilities. Siemens has released an update for SCALANCE X-300 and recommends to update to the latest version.
- WID-SEC-W-2023-0371git und GitLab: Mehrere SchwachstellenDeutsch2023-02-14csaf · cert_bundDE
Ein entfernter, anonymer Angreifer kann mehrere Schwachstellen in git und GitLab ausnutzen, um Informationen offenzulegen und Dateien zu manipulieren.
- WID-SEC-W-2023-1424Xerox FreeFlow Print Server für Solaris: Mehrere SchwachstellenDeutsch2023-06-12csaf · cert_bundDE
Ein Angreifer kann mehrere Schwachstellen in Xerox FreeFlow Print Server ausnutzen, um die Vertraulichkeit, Verfügbarkeit und Integrität des Systems zu gefährden.
- WID-SEC-W-2024-0794Dell ECS: Mehrere SchwachstellenDeutsch2024-04-04csaf · cert_bundDE
Ein Angreifer kann mehrere Schwachstellen in Dell ECS ausnutzen, um seine Privilegien zu erweitern, beliebigen Programmcode mit Administratorrechten auszuführen, Informationen offenzulegen, Dateien zu manipulieren, einen Cross-Site-Scripting-Angriff durchzuführen, Sicherheitsvorkehrungen zu umgehen oder einen Denial of Service Zustand herbeizuführen.
- ICSA-24-046-11Siemens SCALANCE XCM-/XRM-3002024-02-13icsa · cisa_csaf_otUS
SCALANCE XCM-/XRM-300 before V2.4 is affected by multiple vulnerabilities. Siemens has released an update for SCALANCE X-300 and recommends to update to the latest version.
auch bekannt als (3)
Weitere Namen und Kennungen dieser Entität.
quellen
Welche Quellen diesen Datensatz belegen und wann.
Referenzen (20)
Externe Belege — Patches, Meldungen, Analysen.
- https://cxsecurity.com/cveshow/CVE-2023-22490/cnnvd
- https://github.com/git/git/commit/c867e4fa180bec4750e9b54eb10f459030dbebfdcnnvd
- https://github.com/git/git/security/advisories/GHSA-3wp6-j8xr-qw85cnnvd
- https://github.com/git/git/security/advisories/GHSA-gw92-x3fm-3g3qcnnvd
- https://msrc.microsoft.com/update-guide/vulnerability/CVE-2023-22490cnnvd
- https://www.auscert.org.au/bulletins/ESB-2023.0955cnnvd
- https://www.auscert.org.au/bulletins/ESB-2023.1346cnnvd
- https://www.auscert.org.au/bulletins/ESB-2023.2973cnnvd
Angreifer nutzen Schwachstellen wie diese gegen im Internet exponierte Dienste aus. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.
Kostenloser Scan